Search NASASearch

Engineering topics

Elsner, R. F.

Publications and source records attributed to Elsner, R. F..

At least 73 records · Page 4

Status of the Stellar X-Ray Polarimeter for the Spectrum-X-Gamma mission

The Stellar X-Ray Polarimeter (SXRP) uses the polarization sensitivity of a graphite Bragg crystal and a lithium Thomsom scattering target to measure the polarization of X-rays from astrophysical sources. The SXRP is a focal plane detector for the Soviet-Danish SODART telescopes which will be launched on the Soviet Spectrum-X-Gamma mission. The SXRP will be the third orbiting stellar X-ray polarimeter, and should provide an order of magnitude increase in polarization sensitivity over its predecessors.

Kaaret, P.

Off-axis effects on the performance of a scattering polarimeter at the focus of an X-ray telescope

Scattering from bound electrons in a suitable material placed at the focus of an X-ray telescope can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. Among the factors that affect the performance of such an instrument is a spurious polarization signal from unpolarized sources that lie within the field of view but are offset from the telescope pointing direction. This paper presents the results of analytical and Monte Carlo studies of this effect and provides means of evaluating its impact on realistic polarimeters for X-ray astronomy.

Elsner, R. F.

On the performance of the scattering and crystal polarimeters for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is enhanced if the polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the components of the Stellar X-ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The expected on-axis performance of the two components is described based on detailed Monte Carlo simulations. The polarimetry experiment is expected to provide sensitive measurements of linear polarization for many cosmic X-ray sources. The nature and utility of such observations is described for pulsing X-ray sources such as the Crab pulsar and Her X-1.

Elsner, R. F.

Shot noise cross-correlation functions and cross spectra - Implications for models of QPO X-ray sources

The cross-correlation functions (CCFs) and cross spectra expected for quasi-periodic oscillation (QPO) shot noise models are calculated under various assumptions, and the results are compared to observations. Effects due to possible coherence of the QPO oscillations are included. General formulas for the cross spectrum, the cross-phase spectrum, and the time-delay spectrum for QPO shot models are calculated and discussed. It is shown that the CCFs, cross spectra, and power spectra observed for Cyg X-e2 imply that the spectrum of the shots evolves with time, with important implications for the interpretation of these functions as well as of observed average energy spectra. The possible origins for the observed hard lags are discussed, and some physical difficulties for the Comptonization model are described. Classes of physical models for QPO sources are briefly addressed, and it is concluded that models involving shot formation at the surface of neutron stars are favored by observation.

Shibazaki, N.

Moment constraints on physical models for quasi-periodic oscillations from Galactic X-ray sources

Shot-noise models provide a useful mathematical representation for some physical models for the quasi-periodic oscillations (QPOs) recently observed from several bright Galactic bulge and burst X-ray sources. Expressions are calculated for the first three moments for several versions of QPO shot-noise models that have appeared in the literature. It is shown that measurement of the third moment, together with measurement of the mean intensity and the power spectrum, can provide model-dependent constraints on important parameters of QPO shot-noise models, including the fraction of the X-ray intensity in shots and the shot rate. Under certain condtitions, a complete solution for all the shot-model parameters is possible.

Elsner, R. F.

The effect of a hot, spherical scattering cloud on quasi-periodic oscillation behavior

A Monte Carlo technique is used to investigate the effects of a hot electron scattering cloud surrounding a time-dependent X-ray source. Results are presented for the time-averaged emergent energy spectra and the mean residence time in the cloud as a function of energy. Moreover, after Fourier transforming the scattering Green's function, it is shown how the cloud affects both the observed power spectrum of a time-dependent source and the cross spectrum (Fourier transform of a cross correlation between energy bands). It is found that the power spectra intrinsic to the source are related to those observed by a relatively simple frequency-dependent multiplicative factor (a transmission function). The cloud can severely attenuate high frequencies in the power spectra, depending on optical depth, and, at lower frequencies, the transmission function has roughly a Lorentzian shape. It is also found that if the intrinsic energy spectrum is constant in time, the phase of the cross spectrum is determined entirely by scattering. Finally, the implications of the results for studies of the X-ray quasi-periodic oscillators are discussed.

Bussard, R. W.

The effects of contamination on gaseous X-ray detectors

Results are presented which detail how the performance of a proportional counter degrades when oxygen is added as a contaminant. It is demonstrated that argon based gas fillings are much less sensitive to electronegative impurities than are xenon filled detectors which can show significant deterioration for contamination levels as low as 10 ppm. The data are particularly relevant to X-ray astronomy, where sealed systems must operate for long periods of time.

Ramsey, B. D.

The effect of decay of the amplitude of oscillation on random process models for QPO X-ray stars

Random process models provide a useful mathematical framework for analysis of the quasi-periodic oscillations (QPO) recently discovered in the X-ray emission from certain luminous Galactic X-ray stars. In this paper, consideration is given to the effects of the power spectrum of the decay of the amplitude of oscillation that is expected in some physical models for the QPO phenomena. The resulting changes in the power spectrum depend on the ratio of the decay time of the amplitude of oscillation to the lifetime of the shot envelope. For values of this ratio less than about 10, it is found that incoherent QPO peaks in the power spectrum are significantly reduced in height and total power and are broadened in width, making them more difficult to detect. Coherent terms in the power spectrum, if present, are reduced in height and total power, but their width is unaffected. The red noise component remains unchanged. The present results are applied to the beat-frequency modulated accretion model in order to set constraints on the physical properties of the boundary layer between the inner edge of the accretion disk and the neutron star magnetosphere.

Shibazaki, N.

Coherence effects on quasi-periodic oscillations from Galactic X-ray sources

Shot noise models provide a useful mathematical representation for some physical models for the quasi-periodic oscillations recently observed from several Galactic bulge and burst X-ray sources. For such models, correlations between the shot onset times and oscillation phases can have important effects on the expected autocorrelation function and power spectrum, with important consequences for the interpretation of observed power spectra. Making use of analytic and Monte Carlo techniques, two physically plausible correlations of this kind, one corresponding to drift and jitter in the oscillation phase and the other to a random walk in the oscillation phase, are examined.

Elsner, R. F.

Accretion onto neutron stars with the presence of a double layer

It is known, from laboratory experiments, that double layers will form in plasmas, usually in the presence of an electric current. It is argued that a double layer may be present in the accretion column of a neutron star in a binary system. It is suggested that the double layer may be the predominant deceleration mechanism for the accreting ions, especially for sources with X-ray luminosities of less than about 10 to the 37th erg/s. Previous models have involved either a collisionless shock or an assumed gradual deceleration of the accreting ions to thermalize the energy of the infalling matter.

Williams, A. C.

Observations of quasi-periodic oscillations from GX 5 - 1 and Cygnus X-2 with the Einstein (HEAO 2) Observatory

The bright galactic bulge X-ray source GX 5 - 1 was observed in April 1979 with the Monitor Proportional Counter on board the Einstein (HEAO 2) Observatory. Analysis of the high time resolution data from the Time Interval Processor confirms the recent Exosat discovery of quasi-periodic oscillations in the X-ray emission from GX 5 - 1. In addition, the summed 0.4 s power spectrum shows the low-frequency red noise component also discovered in the Exosat data. Low-frequency structure is also clearly present in data taken from the bright galaxtic X-ray source Cyg X-2 in December 1978. The expected power spectrum for quasi-periodic oscillations was calculated, including the low-frequency red noise component, using a simple shot noise model with oscillating shots.

Elsner, R. F.

Accretion onto neutron stars with the presence of a double layer

It is known from laboratory experiments that double layers can form in plasmas, usually in the presence of an electric current. It is argued that a double layer may be present in the accretion column of a neutron star in a binary system. It is suggested that the double layer may be the predominant deceleration mechanism for the accreting ions, especially for sources with X-ray luminosities of less than about 10 to the 37th erg/s. Previous models have involved either a collisionless shock or an assumed gradual deceleration of the accreting ions to thermalize the energy of the infalling matter.

Williams, A. C.

Development of a multistep detector for X-ray astronomy

The addition of a preamplification region is shown to dramatically improve the performance of a standard multiwire proportional counter (MWPC). This improvement is a direct consequence of effecting a large degree of preamplification in a perfectly uniform electric field and then transferring a well defined portion of this charge to a MWPC running at a modest gain. In this way, very large overall gas gains can be achieved without compromising energy resolution. The resulting device is known as a multistep detector.

Ramsey, B. D.

A fluorescent gated proportional counter for X-ray astronomy

The development of a position-sensitive proportional counter having a large drift volume is reported. It incorporates a fluorescent gating technique which results in a large improvement in background rejection over conventional proportional counters, and in addition offers the benefit of enhanced energy resolution (predicted to be about 3 percent at 40 keV) above the K shell of Xe.

Ramsey, B. D.

X-ray observations of GX 1 + 4 with the monitor proportional counter on board the Einstein Observatory

The results of X-ray observations of GX 1 + 4 with the monitor proportional counter on board the Einstein Observatory (HEAO 2) are presented. Using data from the time interval processor, the value of the approximately 2 minute pulse period at the time of the observations was determined. Previous determinations are discussed, along with evidence for a suggested value of approximately 4 minutes for the pulse period. The phase of first harmonic of the Fourier decomposition of pulse profile is stable within its errors but the phases of higher harmonics are not. The spin-up time scale is determined to be approximately 40 years.

Elsner, R. F.

On fast X-ray rotators with long-term periodicities

The support of previous SAS 3 spacecraft observations by new data gathered by the Monitor Proportional Counter aboard the HEAO 2 spacecraft indicates that the pulse period history of the 13.5 sec-pulsing X-ray source LMC X-4 is consistent with standard accretion and torque models only if LMC X-4 is a fast rotator for which the accretion torques nearly cancel. This result leads to a neutron star magnetic field strength estimate of about 1.2 x 10 to the 13th G. Strong evidence is noted for Her X-1's status as a fast rotator, while SMC X-1 is probably an intermediate-to-fast rotator. In the context of slaved disk models for these objects, it is noted that the precession periods expected for the companion stars are significantly longer than the observed 1-2 month time scales; slaved disk models are thereby undermined.

Naranan, S.

Hydrogen-like atoms on the surface of neutron stars - Intense magnetic field effects

It is known that very strong (greater than 1-TG) magnetic fields exist on the surface of some neutron stars. The properties of atoms in fields of this nature are considerably different from those of atoms in field-free regions. Because of the mixing of spherical and cylindrical symmetries, the analytical solution to the problem of a hydrogen atom in a uniform magnetic field is impossible to obtain. In this work, a variational wave function is used to describe the properties of hydrogen like atoms in intense magnetic fields including first-order relativistic effects. Special attention is given to the transition matrix elements for the 2p(0) - 1s(0) transition in Fe XXVI.

Williams, A. C.

On the viability of exploiting L-shell fluorescence for X-ray polarimetry

It has been suggested that one may build an X-ray polarimeter by exploiting the polarization dependence of the angular distribution of L-shell fluorescence photons. In this paper the sensitivity of this approach to polarimetry is examined theoretically. The calculations are applied to several detection schemes using imaging proportional counters that would have direct application in X-ray astronomy. It is found, however, that the sensitivity of this method for measuring X-ray polarization is too low to be of use for other than laboratory applications.

Weisskopf, M. C.