Value contamination avoidance devices

Mechanical redesign methods were used to minimize contamination damage of conventional fluid components and a contamination separator device was developed for long term reusable space vehicles. These were incorporated into an existing 50.8 mm poppet valve and tested for damage tolerance in a full size open loop flow system with gaseous and liquid nitrogen. Cyclic and steady flow conditions were tested with particles of 125 to 420 micrometers aluminum oxide dispersed in the test fluids. Nonflow life tests (100,000 cycles) were made with two valve configurations in gaseous hydrogen. The redesigned valve had an acceptable cycle life and improved tolerance to contamination damage when the primary sealing surfaces were coated with thin coatings of hard plastic (Teflon S and Kynar). Analytical studies and flow testing were completed of four different versions of the separator. overall separation efficiencies in the 55-90% range were measured with these non-optimum configurations.

Endicott, D. L.

Contamination avoidance devices for poppettype shutoff valves

The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.

Endicott, D. L.

Contamination damage avoidance concepts for propulsion feed system components.

The potential gain in the reliability of reusable long-term mission vehicles through the minimization of component damage due to the ingestion of particulate contamination by feed system components has been recognized by the NASA-LeRC and MDAC, and a program to investigate these problems has been completed. This investigation covered the determination of the cycle life of a typical 2-in. poppet type of shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O2 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full flow and cyclic operating conditions, redesigned to improve the damage tolerance to contaminants and then retested. A second method of approach to damage tolerance control was investigated through the evaluation of various types of particulate separation devices. The study included various types of dynamic separators but did not cover conventional filter assemblies.

Endicott, D. L.

Improved lip seal for rotating shafts

Sealing efficiency, service life, and seal loading limits of lip seal for rotating shafts are analyzed. Construction of seal and areas of application are described. Specific advantages of improved lip seal over conventional seals are listed.

Endicott, D. L.

Contamination avoidance devices for poppet type shutoff valves

The technology required to provide acceptable contamination damage avoidance characteristics for poppet type shutoff valves is discussed. Evaluation of the contamination avoidance characteristics of the basic 1T32095 propellant shutoff valve, the cycle life performance of these valves in an uncontaminated environment, and the effectiveness of various auxiliary contamination avoidance devices when used in conjunction with these poppet type valves are included. In addition, a secondary objective is to evaluate two methods of monitoring the performance of the test valves during actual operations using acoustical monitoring instrumentation.

Endicott, D. L.

Space-storable oxidizer valve Final report

Fabrication and acceptance testing, fluorine compatibility testing, valve refurbishment and testing, environmental testing, and design of space storable oxidizer valve