Search NASA⌕ Search

Engineering topics

Endler, Michael

Publications and source records attributed to Endler, Michael.

Bolometer tomography on Wendelstein 7-X for study of radiation asymmetry

The algorithm for bolometer tomography at Wendelstein 7-X (W7-X) has been recently improved using a novel regularization functional, based on relative gradient smoothing (RGS) of the sought radiation profile. It has been validated using radiation patterns provided by 3D modeling under real plasma conditions as phantoms and then applied to bolometer measurements performed during the first divertor operation phase of W7-X. The following results are presented: 1) edge-localized 2D radiation patterns with clearly resolved magnetic island radiation structures, 2) an up-down asymmetry in the impurity radiation that is not captured by the 3D edge plasma transport modeling, 3) reversal of the asymmetry with reversed magnetic field direction. Further analysis reveals a poloidal variation of the emissivity in the outer confined plasma region with a field-direction dependent asymmetry, also supported by the soft X-ray measurements. This asymmetry is considered to be related to asymmetric impurity distributions, driven by the pronounced ion-impurity friction force at the plasma edge where the collisionality of the W7-X plasma is sufficiently high to develop impurity asymmetry as predicted by neoclassical theory of parallel impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EMC3-EIRENE simulation of first wall recycling fluxes in W7-X with relation to H-alpha measurements

In the Wendelstein 7-X stellarator, the main locations of particle sources are expected to be the carbon divertors, baffles and graphite heat shield first wall. In this paper, the heat shield is implemented in EMC3-EIRENE to understand the expected areas and magnitudes of the recycling flux to this component. It is found that in the simulation the heat shield is not a significant source of recycling neutrals. The areas of simulated recycling flux are shown to correlate well with footprints of plasma-wetting seen in post-experimental campaign in-vessel inspection photos. EMC3-EIRENE reconstruction of line-integrated H-alpha measurements at the heat shield indicate that the majority of emission does not come from local recycling neutrals. Rather, the H-alpha signals at the heat shield are dominated by ionization of neutrals which have leaked from the divertor/baffle region into the midplane. The magnitude of the H-alpha line emission from the synthetic reconstruction is consistent with the experiment, indicating that a large overestimation of heat shield recycling would occur if these measurements were assumed to be from local recycling sources. In the future, it may be possible to obtain some information of local recycling from the heat shield since it was found that the majority of the recycling flux occurs on two well-localized areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma filaments in the scrape-off layer of Wendelstein 7-X

Plasma filaments have been observed by reciprocating electric probes in the Scrape-Off Layer (SOL) of the Wendelstein 7-X stellarator. Comparison with target probes indicates that a filament observed in the W7-X SOL extends to the sheath. Two-dimensional simulations of seeded filaments exhibit good quantitative agreement with experimental measurements in filament velocity scalings, despite an assumption of constant field line curvature. Both experiment and simulation show a slow radial propagation of filaments, indicating that filaments are essentially bound to their flux surface and do not perform ballistic radial motion. In contrast, the poloidal propagation along flux surfaces is much faster than the radial motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of toroidal plasma currents on the Wendelstein 7-X Scrape-Off Layer

The role of toroidal plasma currents for the island divertor scrape-off layer in the stellarator Wendelstein 7-X is investigated using reciprocating electric probes. Experiments show that small amounts (of a few kA) of plasma current are sufficient to significantly affect the scrape-off layer plasma conditions, whereas higher plasma currents above 10kA result in more drastic changes. This behavior is linked to the effect of the plasma current on the rotational transform profile, which can result in significant shifts of the edge magnetic islands. These shifts affect the interaction of the islands with the divertor and can eventually result in a transition from a diverted to a limited plasma configuration. The probe observations are complemented by further edge diagnostics including plasma flow measurements, divertor Langmuir probes, divertor thermography and impurity spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning of the rotational transform in Wendelstein 7-X

The control of rotational transform in Wendelstein 7-X (W7-X) is key to the island divertor operation and safety of plasma facing components. The island divertor concept in W7-X relies on an edge flux surface with rotational transform of $t$ = 1 resonating with an intrinsic n/m = 5/5 resonance to form a five lobed island chain. This island chain intersects with divertor plates to give rise to the island divertor. Changes in the relative position of the rational surface and the divertor plates can result in changes in divertor performance, thus the control of the rotational transform is essential to operation of the W7-X device. During the first divertor campaign electromagnetic loads resulted in elastic deformations of the shaped modular stellarator coils. Such deformations made these coils more planar, reducing the vacuum rotational transform, subsequently shifting the $t$ = 1 resonance outward. Unintended plasma wall interactions provided the first clear evidence of this effect during plasma operation. Flux surface measurements were utilized to estimate the correct level of current in the planar coils for correction of $t$, and found to be around ~-100 A . Scans of the planar coil current for iota correction were performed during plasma operation. These measurements suggest planar coil currents between -250 and ~ 0 A would place the strike lines at the designed distance from the pumping gaps. Divertor Langmuir and upstream probe measurements confirm these estimates along with measurements of divertor neutral gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error fields in the Wendelstein 7-X stellarator

The role of error fields in stellarators is explored in this work through simulations of, and experiments performed on, the Wendelstein 7-X (W7-X) stellarator. Previous experimental results, based on limiter plasmas in W7-X, suggest that error fields are small in the experiment based on limiter plasmas. In this work, we document results from the first divertor campaign on W7-X with a focus on error fields resonant with the edge island divertor structure. Measurements obtained using divertor thermocouples corroborate earlier limiter results that the error fields are small and correctable, requiring only 5% of the total rated current of the trim coil system. The effect of these error fields on magnetic geometry and topology are investigated using the flux surface measurement technique. The resulting divertor thermal load asymmetry is modeled via field line diffusion and compared to experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confirmation of the topology of the Wendelstein 7-X magnetic field to better than 1:100,000

Fusion energy research has in the past 40 years focused primarily on the tokamak concept, but recent advances in plasma theory and computational power have led to renewed interest in stellarators. The largest and most sophisticated stellarator in the world, Wendelstein 7-X (W7-X), has just started operation, with the aim to show that the earlier weaknesses of this concept have been addressed successfully, and that the intrinsic advantages of the concept persist, also at plasma parameters approaching those of a future fusion power plant. Here we show the first physics results, obtained before plasma operation: that the carefully tailored topology of nested magnetic surfaces needed for good confinement is realized, and that the measured deviations are smaller than one part in 100,000. Lastly, this is a significant step forward in stellarator research, since it shows that the complicated and delicate magnetic topology can be created and verified with the required accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

W7-X magnetic diagnostics: Rogowski coil performance for very long pulses

Stellerators can be operated without the need of significant plasma current for generation of poloidal magnetic field components. Wendelstein 7-X (W7-X) is optimized for stiff magnetic configurations by minimizing pressure driven currents, such as bootstrap and Pfirsch-Schlueter currents. In Addition to the largely reduced plasma currents, the HELIAS-type device is a low magnetic shear configuration required for magnetic boundary islands. However, the diverting magnetic field structure is already influenced by small net plasma currents. In particular, the W7-AS divertor results revealed a significant sensitivity of the X-point location with respect to favorable edge plasma states. Thus, a precise X-point control for W7-X is envisaged and, although expected net plasma currents range in the order of 10-100 kA only, stabilization by adaptive controllers is foreseen to an accuracy of about 1 kA. This stabilization should be reliable even after 2000 s of plasma operation. A precondition for achieving this is a reliable current detection. For this purpose, W7-X will be equipped with Rogowski of which the first has now been assembled onto one of the plasma vessel sectors. The integral performance and sensitivity inhomogeneities have been tested by employing the digital integrator of W7-X [A. Werner, Rev. Sci. Instrum. 77, 10E307 (2006)] and a cable energized with 200 A, representing the plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗