Search NASA⌕ Search

Engineering topics

Eng, B.

Publications and source records attributed to Eng, B..

Optical constants of polycrystalline Al 0.25 Ga 0.75 P and Al 0.9 Ga 0.1 As determined by variable-angle spectroscopic ellipsometry

The optical constants of single-crystal Al x Ga 1-x P and Al x Ga 1-x As have been widely studied at various Al compositions but have not yet been thoroughly investigated as polycrystalline materials. Using variable-angle spectroscopic ellipsometry, we estimate and analyze the optical constants of polycrystalline Al 0.25 Ga 0.75 P and Al 0.9 Ga 0.1 As that were non-epitaxially deposited at deposition temperatures of either 250 or 420 °C, and with various dopant species, dopant concentrations, and V/III flux ratios. Here, for wavelengths of 350–400 nm, decreasing the V/III ratio increases the refractive index of Be-doped polycrystalline Al 0.25 Ga 0.75 P. For wavelengths >500 nm, as the targeted Be dopant concentration increases for polycrystalline Al 0.25 Ga 0.75 P, the amount the extinction coefficient increases and the indirect bandgap decreases depends on the V/III ratio. Furthermore, Si-doped polycrystalline Al 0.25 Ga 0.75 P has significantly smaller extinction coefficient values than when it is Be-doped, for the same V/III ratio and targeted doping concentration, at wavelengths >500 nm. Based on our findings, we hypothesize that the dopant species, dopant concentration, and the V/III ratio dictate various types of defect concentrations, which then affect the optical constants and indirect bandgap of polycrystalline Al 0.25 Ga 0.75 P. Additionally, for wavelengths >500 nm, we find that polycrystalline Al 0.25 Ga 0.75 P and Al 0.9 Ga 0.1 As have the lowest extinction coefficient values when deposited at 420 °C, as opposed to 250 °C. Thus, we hypothesize that the deposition temperature is the most significant factor in dictating the optical constants of these polycrystalline III-Vs. Ultimately, this work demonstrates alternative methods to tune the optical constants of polycrystalline Al 0.25 Ga 0.75 P and Al 0.9 Ga 0.1 As, as opposed to tuning the Al composition.

42 ENGINEERING↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

The CLAS12 superconducting magnets

As part of the Jefferson Lab 12 GeV upgrade, the Hall B CLAS12 system requires two superconducting iron-free magnets — a torus and a solenoid. The physics requirements to maximize space for the detectors guided engineers toward particular coil designs for each of the magnets which, in turn, led to the choice of using conduction cooling. The torus consists of 6 trapezoidal NbTi coils connected in series with an operating current of 3770 A. The solenoid is an actively shielded 5 T magnet consisting of 5 NbTi coils connected in series operating at 2416 A. Within the hall, the two magnets are located in close proximity to each other and are completely covered both inside and outside by particle detectors. Stringent size limitations were imposed for both magnets and introduced particular design and fabrication challenges. This paper describes the design, construction, installation, commissioning, and operation of the two magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of a Very Large Atmospheric Correction Lookup Table for ASTER Using a Relational Database Management System

The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER)is designed to provide a high resolution map of the Earth in both visible, near-infrared, and thermal spectral regions of the electromagnetic spectrum. The ASTER Science Team has developed several standard data product algorithms, but the most complex aod computing-intensive of these is the estimation of surface radiance and reflectance values, which is done by modeling and correcting for the effects of the atmosphere. The algorithm for atmospheric correction in the visible bands sensed by ASTER calls for use of a very large Atmospheric Correction Look Up Table (ACLUT).

ASTER↗

Rotating Capacitor Measures Steady Electric Fields

Portable sensor measures electric fields created by dc powerlines or other dc-high-voltage sources. Measures fields from 70 to 50,000 V/m with linearity of 2 percent. Sensor used at any height above ground. Measures both magnitude and direction of field and provides signals representing these measurements to remote readout device. Sensor functions with minimal disturbance of field it is measuring.

Johnston, A. R.↗

A 250-Mbit/s ring local computer network using 1.3-microns single-mode optical fibers

A 250-Mbit/s three-station fiber-optic ring local computer network was built and successfully demonstrated. A conventional token protocol was employed for bus arbitration to maximize the bus efficiency under high loading conditions, and a non-return-to-zero (NRS) data encoding format was selected for simplicity and maximum utilization of the ECL-circuit bandwidth.

Eng, S. T.↗