Search NASA⌕ Search

Engineering topics

Engelhorn, K.

Publications and source records attributed to Engelhorn, K..

At least 19 records

Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility

The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of electron-phonon coupling in warm dense iron

The electron-ion relaxation dynamics in warm dense iron were investigated by time-resolved x-ray absorption near-edge spectroscopy (XANES). A novel analysis, combining ab initio density functional theory (DFT) and two temperature model (TTM) simulations, was developed to calculate the x-ray absorption spectra as a function of delay time. Here we present experimental evidence of changes at the XAS L3 edge of iron that are consistent with the reduction of the electron-phonon coupling under warm dense matter conditions. The experimental results are in agreement with the model that takes both the electron ($T_e$) and the ion temperature ($T_i$) dependence of the thermophysical properties into consideration, while models where either constant electron-phonon coupling factor (G) or only $T_e$- dependent G are used do not agree with the observed relaxation dynamics of iron.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The dilation aided single–line–of–sight x–ray camera for the National Ignition Facility: Characterization and fielding

Crystal x–ray imaging is commonly used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. Yet, currently used x–ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single–line–of–sight x–ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns–scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single–line–of–sight with high spatial and temporal resolution. Presently, the instrument can record two single–line–of–sight images with spatial and temporal resolution of 35 μm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single–line–of–sight camera for the NIF, including the x–ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

47 OTHER INSTRUMENTATION↗

Sub-nanosecond single line-of-sight (SLOS) x-ray imagers (invited)

A new generation of fast-gated x-ray framing cameras have been developed that are capable of capturing multiple frames along a single line-of-sight with 30 ps temporal resolution. The instruments are constructed by integrating pulse-dilation electron imaging with burst mode hybrid-complimentary metal-oxide-semiconductor sensors. Two such instruments have been developed, characterized, and fielded at the National Ignition Facility and the OMEGA laser. These instruments are particularly suited for advanced x-ray imaging applications in Inertial Confinement Fusion and High energy density experiments. Here, we discuss the system architecture and the techniques required for tuning the instruments to achieve optimal performance. Characterization results are also presented along with planned future improvements to the design.

47 OTHER INSTRUMENTATION↗

Hydrodynamic instability seeding by oxygen nonuniformities in glow discharge polymer inertial fusion ablators

Here, the U.S. indirect drive inertial confinement fusion (ICF) program uses glow discharge polymer (GDP) as one of the ablator materials for the ICF experiments at the National Ignition Facility (NIF). The performance of those implosions may be adversely affected by photoactivated uptake of oxygen impurities in the surface of the GDP ablator. These impurities can induce significant perturbations in the shock waves generated in the ablator. These perturbed shocks generate mass modulations that are amplified by Rayleigh-Taylor (RT) instability and reduce the performance of the implosions. Here we report on experiments that provide a quantitative connection between photoactivated oxygen uptake in GDP samples and modulations in shock velocities in the samples. The observed shock nonuniformity confirms the hypothesis that irregular oxygenation is a competent seed for the RT and can have a significant effect on NIF GDP implosions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metrology Feasibility Study in Support of the National Direct-Drive Program

The 100 Gbar Laser Direct Drive (LDD) program calls for ablator capsules with no defects larger than 0.5 μm in lateral dimension and fewer than ten defects with lateral dimensions between 0.1-0.5 μm. Comparing to Laser Indirect Drive (LID) capsules, this represents >10x reduction of defect length scale and >500x reduction in defect number density. This presents major challenges to both fabrication and metrology. In this paper, we will discuss the proof-of-principle work conducted at General Atomics to identify metrology techniques suitable for 100 Gbar target characterization. We present a detailed studies of dark-field imaging, laser scatterometry, and environmental scanning electron microscopes. We identify dark-field imaging as the best approach for meeting the 100 Gbar metrology needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of Reverse Saturable Absorption of an X-ray Laser

A nonlinear absorber in which the excited state absorption is larger than the ground state can undergo a process called reverse saturable absorption. It is a well-known phenomenon in laser physics in the optical regime, but is more difficult to generate in the x-ray regime, where fast nonradiative core electron transitions typically dominate the population kinetics during light matter interactions. Here, we report the first observation of decreasing x-ray transmission in a solid target pumped by intense x-ray free electron laser pulses. The measurement has been made below the K-absorption edge of aluminum, and the x-ray intensity ranges are 10 16 –10 17 W=cm 2 . It has been confirmed by collisional radiative population kinetic calculations, underscoring the fast spectral modulation of the x-ray pulses and charge states relevant to the absorption and transmission of x-ray photons. The processes shown through detailed simulations are consistent with reverse saturable absorption, which would be the first observation of this phenomena in the x-ray regime. These light matter interactions provide a unique opportunity to investigate optical transport properties in the extreme state of matters, as well as affording the potential to regulate ultrafast x-ray freeelectron laser pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of continuum lowering in solid-density plasmas created from elements and compounds

The effect of a dense plasma environment on the energy levels of an embedded ion is usually described in terms of the lowering of its continuum level. For strongly coupled plasmas, the phenomenon is intimately related to the equation of state; hence, an accurate treatment is crucial for most astrophysical and inertial-fusion applications, where the case of plasma mixtures is of particular interest. In this study, we present an experiment showing that the standard density-dependent analytical models are inadequate to describe solid-density plasmas at the temperatures studied, where the reduction of the binding energies for a given species is unaffected by the different plasma environment (ion density) in either the element or compounds of that species, and can be accurately estimated by calculations only involving the energy levels of an isolated neutral atom. Lastly, the results have implications for the standard approaches to the equation of state calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-rays only when you want them: Optimized pump–probe experiments using pseudo-single-bunch operation

Laser pump–X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser excitation pulse rates. Suppressing undesired X-ray pulses considerably reduces detector noise and improves signal to noise in time-resolved experiments. In addition, dose-induced sample damage is considerably reduced, easing experimental setup and allowing the investigation of less robust samples. Single-shot X-ray exposures of a streak camera detector using a conventional non-gated charge-coupled device (CCD) camera are also demonstrated.

43 PARTICLE ACCELERATORS↗