Engineering topics
Enzer, Daphna G.
Publications and source records attributed to Enzer, Daphna G..
Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors
GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.
Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space
Researchers have used data from the GRAIL mission to the Moon to make the first in-flight verification of ultra-stable oscillators (USOs) with Allan deviation below 10 13 for 1-to-100-second averaging times. USOs are flown in space to provide stable timing and/or navigation signals for a variety of different science and programmatic missions. The Gravity Recovery and Interior Laboratory (GRAIL) mission is flying twin spacecraft, each with its own USO and with a Ka-band crosslink used to measure range fluctuations. Data from this crosslink can be combined in such a way as to give the relative time offsets of the two spacecrafts USOs and to calculate the Allan deviation to describe the USOs combined performance while orbiting the Moon. Researchers find the first direct in-space Allan deviations below 10(exp -13) for 1-to-100-second averaging times comparable to pre-launch data, and better than measurements from ground tracking of an X-band carrier coherent with the USO. Fluctuations in Earth s atmosphere limit measurement performance in direct-to-Earth links. Inflight USO performance verification was also performed for GRAIL s parent mission, the Gravity Recovery and Climate Experiment (GRACE), using both Kband and Ka-band crosslinks.
GRAIL - A Microwave Ranging Instrument to Map Out the Lunar Gravity Field
Gravity Recovery and Interior Laboratory, or GRAIL, is a NASA mission to map out the gravity field of the moon to an unprecedented level of detail. The instrument for this mission is based on GRACE (Gravity Recovery and Climate Experiment), an earth-orbiting mission currently mapping out the gravity field of the earth. This paper will describe the similarities and differences between these two instruments with a focus on the microwave ranging measurements used to determine the gravity parameters and the testbed built at Jet Propulsion Laboratory to demonstrate micron level ranging capability. The onboard ultrastable oscillator and RF instruments will be described and noise contributions discussed.
Recirculation of Laser Power in an Atomic Fountain
A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.
Performance of the PARCS Testbed Cesium Fountain Frequency Standard
A cesium fountain frequency standard has been developed as a ground testbed for the PARCS (Primary Atomic Reference Clock in Space) experiment, an experiment intended to fly on the International Space Station. We report on the performance of the fountain and describe some of the implementations motivated in large part by flight considerations, but of relevance for ground fountains. In particular, we report on a new technique for delivering cooling and trapping laser beams to the atom collection region, in which a given beam is recirculated three times effectively providing much more optical power than traditional configurations. Allan deviations down to 10 have been achieved with this method.