Search NASA⌕ Search

Engineering topics

Epps, H. W.

Publications and source records attributed to Epps, H. W..

Design for a 1-5-micron cryogenic echelle spectrograph for the NASA IRTF

The design of an infrared cryogenic echelle spectrograph for use on the NASA Infrared Telescope Facility is described. The resolving power achieved over the range 1-5.4 microns is 1-40,000 with slit widths of 2.0-0.5 arcsec. The spectrograph is used in a single order with a 30-arcsec-long slit. No cross dispersion is provided because of the small number of orders that can be observed at once and the need to keep the instrument as small as possible. A closed-cycle cooler is used in lieu of cryogens in order to achieve greater reliability and ease of use at the telescope. The optical layout, the design philosophy, the modes of operation, and the construction details are provided.

Tokunaga, A. T.↗

Advanced wide-field broad-passband refracting field correctors for large telescopes

Design objectives, constraints, and optical data are presented for specific corrector designs under consideration for several large telescope projects. These include a preliminary 30-arcmin prime focus (f/2.0) refracting field corrector system for the University of California Ten-Meter Telescope (UC TMT); a compact 40-arcmin internal Cassegrain (f/1.75 hyperbola to f/5.0) broad-passband (3300 A to 1.0 micron) corrector suitable for imaging and multi-object spectroscopy at the UC TMT; three 60-arcmin Cassegrain correctors for 300-inch f/1.8 and f/2.0 parabolic primary mirrors suitable for a Fifteen-Meter NNTT/MMT; and a 300-inch 40-arcmin external Cassegrain (f/1.0 parabola to f/4.0) broad-passband (3300 A to 1.0 micron) corrector with ADC.

Epps, H. W.↗

Upconversion of broadband infrared spectra

An experimental device successfully upconverts IR radiation in the 3.2-5.0 micron wavelength range simultaneously to visible light at 0.80-0.88 microns, while preserving frequency coding and is thus applicable to IR spectroscopy. The 1.8-micron bandwidth of IR radiation that is upconverted without temperature or phase match tuning is the largest yet reported. The over-all system quantum efficiency of the upconverter/spectrometer system is 0.01% and could be improved to 0.4%.

Gurski, T. R.↗

Astronomical demonstration of an infrared upconverter

An upconverter has been used to convert infrared photons from astronomical sources to higher frequency quanta that were detected with a pulse-counting photomultiplier photometer. It is pointed out that these observations represent the first successful astronomical demonstration of infrared upconversion. Upconversion is carried out in an optically nonlinear medium, which in the upconverter described is a lithium iodate crystal. A 0.6943-micrometer high peak power ruby laser pump was developed for the demonstration.

Gurski, T. R.↗