Search NASA⌕ Search

Engineering topics

Erchinger, Jennifer L.

Publications and source records attributed to Erchinger, Jennifer L..

Multilateral Testing Workshop on Relocatable Portal Monitors

The procurement and deployment of radiation detection equipment is a multi-faceted challenge across the globe. Knowledge sharing of the testing methods used to evaluate equipment for deployment scenarios helps improve the understanding of deployed systems by the global community. The United States Department of Energy’s Nuclear Smuggling Detection and Deterrence Office (NSDD) performed a series of characterization measurements in 2019, focused on radiation detection systems that could function as relocatable portal monitors. The capstone activity for this project was a multilateral and cross-disciplinary workshop demonstrating, performing, and refining the techniques used in the characterization measurements with International Atomic Energy Agency (IAEA) and global partners. A group of technical experts including representatives from nine countries, the IAEA, and NSDD gathered at Sandia National Laboratories in Albuquerque, NM during September of 2019 for the Operational and Performance Testing and Evaluation of Relocatable Portals Workshop. Over the course of a week, the group discussed the necessity for and process of developing operational and performance requirements, challenges related to deploying radiation detection systems for the countries in attendance, use cases for deploying relocatable radiation detection equipment, and considerations related to testing equipment for appropriate deployment scenarios. All participants were given the opportunity to have hands-on experience with eleven relocatable systems in executing a limited scope characterization test comprised of six test scenarios. At the conclusion of testing, participants reviewed and presented their findings, and the group as a whole compared and contrasted their experiences. Suggested revisions to the test methods and ideas for further collaborations were discussed. This report discusses the logistical and planning considerations for bringing together experts across disciplines in a multilateral workshop on testing of radiation detectors, as well as presenting the testing methods performed, results, and paths forward. Success of workshops related to technical knowledge transfer and improvement of test methods is key to global technical and scientific support of radiation detection deployments.

Erchinger, Jennifer L.↗

Liquid Scintillation Counting of Environmental Radioisotopes: A Review of the Impact of Background Reduction

Liquid scintillation counting (LSC) is a versatile and commonplace method for radiometric measurement of charged particle emitting radionuclides. The LSC method provides utility in a range of environmental science applications including hydrological studies of water transport, anthropogenic releases of radionuclides into the environment, and vertical mixing rates within oceans. Instrumental measurement background is one limiting factor of radiometric measurement sensitivity. As part of the development of a custom low background LSC system located in a shallow underground laboratory at Pacific Northwest National Laboratory, a number of measurement applications of LSC have been considered and are summarized here. The focus is on determining which aspects of such measurements would gain the greatest benefit from the reduction of LSC backgrounds by a factor of 10-100 relative to values reported in the literature. Examples of benefits include lowering the minimum detectable activity, reducing the sample size required, and shortening the elapsed timeline of the processing and analysis sequence. In particular tritium, strontium, and actinium isotopes are examined as these isotopes cover a range of requirements related to the LSC measurement method (e.g., 3H: low energy; Sr: spectral deconvolution; Ac: alpha/beta discrimination).

actinium↗

Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis

Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 counts per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.

Erchinger, Jennifer L.↗

Development of a low background liquid scintillation counter for a shallow underground laboratory

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

liquid scintillation counting↗