Search NASA⌕ Search

Engineering topics

Erwin, John R

Publications and source records attributed to Erwin, John R.

At least 19 records

Systematic two-dimensional cascade tests of NACA 65-series compressor blades at low speeds

A two-dimensional low-speed porous-wall cascade tunnel investigation has been conducted to establish the performance of the NACA 65-series compressor blade sections over the useful range of inlet angle, solidity, and section camber. Design points for optimum high-speed operation are presented. The loading limitation is determined for some conditions. Trends of section operating range with increasing section camber are determined for the four inlet angles tested.

COMPRESSORS - AXIAL-FLOW↗

Method of Estimating the Incompressible-flow Pressure Distribution of Compressor Blade Sections at Design Angle of Attack

A method was devised for estimating the incompressible-flow pressure distribution over compressor blade sections at design angle of attack. The theoretical incremental velocities due to camber and thickness of the section as an isolated airfoil are assumed proportional to the average passage velocity and are modified by empirically determined interference factors. Comparisons were made between estimated and test pressure distributions of NACA 65-series sections for typical conditions. Good agreement was obtained.

COMPRESSOR FLOW THEORY AND EXPERIMENT↗

Effect of Tunnel Configuration and Testing Technique on Cascade Performance

An investigation has been conducted to determine the influence of aspect ratio, boundary-layer control by means of slots and porous surfaces, Reynolds number, and tunnel end-wall condition upon the performance of airfoils in cascades. A representative compressor-blade section (the NACA 65-(12)(10) of aspect ratios of 1, 2, and 4 has been tested at low speeds in cascades with solid and with porous side walls. Two-dimensional flow was established in porous-wall cascades of each of the three aspect ratios tested; the flow was not two-dimensional in any of the solid-wall cascades. Turbine-blade sections of aspect ratio 0.83 were tested in cascades with solid and porous side walls and blade sections of aspect ratio 3.33 were tested in cascades with solid wall. No particular advantage was observed in the use of porous walls for the turbine cascades tested.

Erwin, John R↗