Search NASA⌕ Search

Engineering topics

Estrada, Juan [Fermilab] (ORCID:0000000215277956)

Publications and source records attributed to Estrada, Juan [Fermilab] (ORCID:0000000215277956).

Searches for CE ν NS and physics beyond the standard model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering ( CE ν NS ) of reactor antineutrinos off silicon nuclei using thick fully depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with subelectron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing, data quality, and event selection for CE ν NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021–2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits for the neutrino interaction rates, comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model improve the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation by CONNIE obtains the best limits on the DM-electron scattering cross section by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of (1.39±0.11)×10^{-5} e^{-}/pix/day, corresponding to (39.8±3.1) e^{-}/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the wavelength range between near-infrared and ultraviolet. We use these data to obtain a 90% confidence level upper bound of 1.53×10^{-5} e^{-}/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

dark matter↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Spectroscopic Stage-5 Experiment

The existence, properties, and dynamics of the dark sectors of our universe pose fundamental challenges to our current model of physics, and large-scale astronomical surveys may be our only hope to unravel these long-standing mysteries. In this white paper, we describe the science motivation, instrumentation, and survey plan for the next-generation spectroscopic observatory, the Stage-5 Spectroscopic Experiment (Spec-S5). Spec-S5 is a new all-sky spectroscopic instrument optimized to efficiently carry out cosmological surveys of unprecedented scale and precision. The baseline plan for Spec-S5 involves upgrading two existing 4-m telescopes to new 6-m wide-field facilities, each with a highly multiplexed spectroscopic instrument capable of simultaneously measuring the spectra of 13,000 astronomical targets. Spec-S5, which builds and improves on the hardware used for previous cosmology experiments, represents a cost-effective and rapid approach to realizing a more than 10$\times$ gain in spectroscopic capability compared to the current state-of-the-art represented by the Dark Energy Spectroscopic Instrument project (DESI). Spec-S5 will provide a critical scientific capability in the post-Rubin and post-DESI era for advancing cosmology, fundamental physics, and astrophysics in the 2030s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗