Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

The Lunar Environment Heliophysics X-Ray Imager (LEXI) Mission

The Lunar Environment heliospheric X-ray Imager (LEXI) is a wide field-of-view soft Xray telescope developed to study solar wind-magnetosphere coupling. LEXI is part of the Blue Ghost 1 mission comprised of 10 payloads to be deployed on the lunar surface. LEXI monitors the dayside magnetopause position and shape as a function of time by observing soft X-rays (0.1–2 keV) emitted from solar wind charge-exchange between exospheric neutrals and high charge-state solar wind plasma in the dayside magnetosheath. Measurements of the shape and position of the magnetopause are used to test temporal models of mesoand macro-scale magnetic reconnection. To image the boundary, LEXI employs lobster-eye optics to focus X-rays to a microchannel plate detector with a 9.1◦ × 9.1◦ field of view.

Lunar↗

Refinement of Transition-Edge Sensor Dimensions for the X-ray Integral Field Unit on ATHENA

At NASA Goddard Space Flight Center, we have previously demonstrated a kilo-pixel array of transition-edge sensor (TES) microcalorimeters capable of meeting the energy resolution requirements of the future X-ray Integral Field Unit (X-IFU) instrument that is being developed for the Advanced Telescope for High ENergy Astrophysics (ATHENA) observatory satellite. The TES design in this array was a square device with side length of 50 μm. Here, we describe studies of TES designs with small variations of the dimensions, exploring lengths, parallel to the current direction, ranging from 75μm to 50μm and widths, perpendicular to the current direction, ranging from 50μm to 15 μm. We describe how these changes impact transition properties, thermal conductance and magnetic field sensitivity. In particular, we show that using a TES with a length of 50μm and width of 30μm may be a promising route to reduce the maximum time-derivative of the TES current in an X-ray pulse and reduce the sensitivity of the TES to magnetic field.

N A Wakeham↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

High-Precision Determination of Oxygen-Kalpha Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O2 with 8 meV-uncertainty. We reveal a systematic ~450meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O2 literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

M A Leutenegger↗

Observation of Strong Two-Electron-One-Photon Transitions in Few-Electron Ions

We resonantly excite the K series of O5+ and O6+ up to principal quantum number n = 11 with monochromatic x rays, producing K-shell holes, and observe their relaxation by soft-x-ray emission. Some photoabsorption resonances of O5+ reveal strong two-electron–one-photon (TEOP) transitions. We find that for the [(1s2s)15p3/2]3/2;1/2 states, TEOP relaxation is by far stronger than the radiative decay and competes with the usually much faster Auger decay path. This enhanced TEOP decay arises from a strong correlation with the near-degenerate upper states [(1s2p3/2 )14s]3/2;1/2 of a Li-like satellite blend of the He-like Kα transition. Even in three-electron systems, TEOP transitions can play a dominant role, and the present results should guide further research on the ubiquitous and abundant many-electron ions where electronic energy degeneracies are far more common and configuration mixing is stronger.

M Togawa↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Extension of the energy range accessible with a TES using bath temperature variations

The energy range of transition-edge sensor (TES) X-ray microcalorimeters with a multiplexed readout depends upon the width and shape of the TES superconducting transition, and also on the dynamic range of the readout. In many detector systems, the multiplexed readout slew rate capability will be the limiting factor for the energy range. In these cases, if we are willing to accept some energy resolution degradation, we can significantly extend the energy range by increasing the bath temperature of operation, essentially creating a second “extended energy range” mode of operation. For example, if we require the very highest energy resolution up to 7 keV, and wish to optimize the design up to this energy, for some measurements it could be very beneficial to have a mode where we can extend the energy range to 15–20 keV even if some energy resolution is sacrificed. In this paper, we explore the trade-off between dynamic range and energy resolution from changing the bath temperature of the TES. We present measurements of TES resolution and slew rate as a function of bath temperature and compare to numerical simulations.

S Beaumont↗

Constraints on the chemical enrichment history of the Perseus Cluster of galaxies from high-resolution X-ray spectroscopy

High-resolution spectroscopy of the core of the Perseus Cluster of galaxies, using the Hitomi satellite above 2 keV and the XMM–Newton Reflection Grating Spectrometer at lower energies, provides reliable constraints on the abundances of O, Ne, Mg, Si, S, Ar, Ca, Cr, Mn, Fe, and Ni. Accounting for all known systematic uncertainties, the Ar/Fe, Ca/Fe, and Ni/Fe ratios are determined with a remarkable precision of less than 10 per cent, while the constraints on Si/Fe, S/Fe, and Cr/Fe are at the 15 per cent level, and Mn/Fe is measured with a 20 percent uncertainty. The average biases in determining the chemical composition using archival CCD spectra from XMM–Newton and Suzaku typically range from 15 to 40 per cent. A simple model in which the enrichment pattern in the Perseus Cluster core and the protosolar nebula are identical gives a surprisingly good description of the high-resolution X-ray spectroscopy results, with X^2=10.7 for 10 degrees of freedom. However, this pattern is challenging to reproduce with linear combinations of existing supernova nucleosynthesis calculations, particularly given the precise measurements of intermediateα-elements enabled by Hitomi. We discuss in detail the degeneracies between various supernova progenitor models and explosion mechanisms, and the remaining uncertainties in these theoretical models. We suggest that including neutrino physics in the core-collapse supernova yield calculations may improve the agreement with the observed pattern ofα-elements in the Perseus Cluster core. Our results provide a complementary benchmark for testing future nucleosynthesis calculations required to understand the origin of chemical elements.

A Simionescu↗

Long Term Performance Stability of TES Detectors

We are developing superconducting transition-edge sensor (TES) microcalorimeter arrays for a variety of applications such as ground-based laboratory astrophysics experiments and next generation space-based X-ray missions. These detectors can provide X-ray spectral information with an unprecedent resolution of ~2 eV at 6 keV and have been selected for the X-ray Integral Field Unit (X-IFU) instrument of ESA’s large flagship mission Athena. To maintain detector performance over the lifetime of the mission, it is important to understand whether environmental conditions that the detector may be exposed to will affect its properties over time. This “aging” begins right after the array leaves the fabrication environment, with potential exposure to humidity, oxygen, or elevated temperatures which may affect the detector performance. In a few prior arrays we have observed increased fall times in the pulse shape and/or the introduction of anomalous low energy tails on the X-ray spectrum. This is thought to be an indication of “aging” on chips exposed to such conditions, causing e.g. changes in the absorber properties. In this contribution, we report on a systematic characterization of TES properties, before and after exposing the chip to various controlled temperature and humidity levels and assess the changes in the measured transition and pulse shapes, energy resolution, and spectral redistribution.

S Beaumont↗

Refinement of the Transition-edge Sensor Design for ATHENA X-IFU

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 2376 transition-edge sensor (TES) microcalorimeter pixels in a single array. The required performance for X-IFU has been demonstrated on a kilo-pixel array of square TES’s with 50 m side length, and this is considered the baseline pixel design. However, over the last few years we have explored small modifications to this design in search of a globally optimized instrument performance. We have previously reported on investigations of extending the length of the TES’s and variations in the number of X-ray absorber support stems. Here we report on investigations of TES designs with a length of 50 m but narrower width. We will discuss the consequence of this on magnetic field sensitivity, resistive transition parameters, spectral performance, and ease of multiplexing. We will also discuss how the number and position of the absorber attachments influences the vibrational modes of the pixels, and the impact this may have on performance. Finally, we will present measurements of more substantial change options of our TES design, including more extreme TES geometries, the use of metal islands or etched holes in the silicon nitride membranes, and the position of wiring to minimize current-induced magnetic field effects. The exploration of all these changes to the design are not only useful for optimizing performance on X-IFU, but also guide our fundamental understanding of the key physics of TES microcalorimeters.

Nick Wakeham↗

Development of the Microcalorimeter Array for the Line Emission Mapper (LEM) X-Ray Probe

The Line Emission Mapper (LEM) is a proposed NASA probe-class mission designed to study the formation of structure in the Universe. LEM will have a 14k pixel array of transition-edge sensor (TES) microcalorimeters that provide a spectral resolution of < 2.5 eV and a bandpass of 0.2-2 keV. In this paper, we report on the status and plan for continued development of the LMS microcalorimeter. This includes details of the TES and x-ray absorber design, and the measured performance in prototype arrays. We present a detailed budget for the energy resolution and show how the properties of the LEM pixels are well optimized for the baseline time-division-multiplexing (TDM) that will be used read out the array. Finally, we describe the design and performance of the first full scale LMS arrays which include the necessary mechanical and electrical interfaces needed for LEM and are a precursor to an engineering model detector.

Stephen J Smith↗