EcoVillage: A Net Zero Energy Ready Community - Ithaca Crawlspace

The U.S. Department of Energy's (DOE) Building America team, Consortium for Residential Buildings (CARB), is working with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This community-scale project consists of 40 housing units-15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. The community is pursuing certifications for DOE Zero Energy Ready Home, U.S. Green Building Council Leadership in Energy and Environmental Design Gold, and ENERGY STAR for the entire project. Additionally, seven of the 25 homes, along with the four-story apartment building and community center, are being constructed to the Passive House (PH) design standard.

Array↗

Multifamily Envelope Leakage Model

“The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deter program participants, and dissuade them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.” This statement found in a 2012 report by Heschong Mahone Group for several California interests emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing—the more appropriate test for assessing energy savings opportunities—could easily be six times that, and that’s only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. This research seeks to provide an algorithm for predicting the guarded blower door test result based upon a single, total blower door test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interaction of Unvented Attics With Living Space in Three Northeast Homes

Unvented roof assemblies are becoming common in North American construction. It is estimated that over 100,000 have been constructed since 1995 (Schumacher 2007). According to RECS 2011, more than 30% of homes with attics can be found in the very cold/cold climate areas, which equals about 10.4 million housing units. The magnitude of these numbers emphases the significance of properly understanding how the attic conditions vary with respect to the conditioned space below.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interaction of Unvented Attics With Living Space in Three Northeast Homes

Unvented roof assemblies are becoming common in North American construction. It is estimated that over 100,000 have been constructed since 1995 (Schumacher 2007). According to RECS 2011, more than 30% of homes with attics can be found in the very cold/cold climate areas, which equals about 10.4 million housing units. The magnitude of these numbers emphases the significance of properly understanding how the attic conditions vary with respect to the conditioned space below.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗