Search NASA⌕ Search

Engineering topics

Fair, Ruben

Publications and source records attributed to Fair, Ruben.

Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb 3 Sn Superconducting Magnets

Here this is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnostics for Burning Plasmas

Here, recent progress in the design and manufacturing development of in-vessel diagnostic components by the U.S. ITER team is reported. Design and manufacturing choices are driven by engineering challenges stemming from ITER’s burning plasma mission, which entails levels of plasma neutron emission, pulse lengths, and size scales well beyond the existing database. Challenges include port access limitations, neutron irradiation and activation risks, nuclear heating of components, complex interfaces, remote handling compatibility, and constraints on component and processing materials. Responses to these challenges are presented using examples from the low field side reflectometer, toroidal interferometer polarimeter, and electron cyclotron emission diagnostics. Relevance of the experience from ITER diagnostics engineering to the design of future integrated fusion facilities based on burning plasmas is addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

Field Mapper for Superconducting Torus Magnet for the Jefferson Lab 12GeV Upgrade

As part of the Jefferson Lab 12 GeV upgrade, the Hall B magnet system requires two conduction cooled superconducting magnets ? a Torus and a Solenoid. The Torus consists of 6 trapezoidal coils connected in series with an operating current of 3770 A. During commissioning of the torus magnet, field mapping was carried out at different levels of operating current in order to determine the field profile and field error table. In order to meet the physics requirement of the field accuracy we need magnetic field strength measurements which are accurate at the 0.1% level, and we need to know radius and azimuth to 0.1 mm and z to 0.5 mm. The center line of the torus magnet is approximately 6 m from ground level and the overall height of the torus magnet is approximately 8.5 m. There is also limited space around the magnet and in between the coils. Field mapping had to be carried out along the Z axis (i.e. along the bore) and at 4 radial locations between each coil. These restrictions provided certain challenges for the magnetic field mapping task. The mapper prototype was built and tested prior to use on the Torus itself. In this presentation the field mapper design, prototyping and actual data collection procedure will be presented.

Rajput-Ghoshal, Renuka↗

The CLAS12 Torus Detector Magnet at Jefferson Laboratory

The CLAS12 Torus is a toroidal superconducting magnet, which is part of the detector for the 12-GeV accelerator upgrade at Jefferson Laboratory (JLab). The coils were wound/fabricated by Fermilab, with JLab responsible for all other parts of the project scope, including design, integration, cryostating the individual coils, installation, cryogenics, I&C, etc. This paper provides an overview of the CLAS12 Torus magnet features and serves as a status report of its installation in the experimental hall. Completion and commissioning of the magnet is expected in 2016.

43 PARTICLE ACCELERATORS↗

Superconductivity for Large Scale Wind Turbines

A conceptual design has been completed for a 10MW superconducting direct drive wind turbine generator employing low temperature superconductors for the field winding. Key technology building blocks from the GE Wind and GE Healthcare businesses have been transferred across to the design of this concept machine. Wherever possible, conventional technology and production techniques have been used in order to support the case for commercialization of such a machine. Appendices A and B provide further details of the layout of the machine and the complete specification table for the concept design. Phase 1 of the program has allowed us to understand the trade-offs between the various sub-systems of such a generator and its integration with a wind turbine. A Failure Modes and Effects Analysis (FMEA) and a Technology Readiness Level (TRL) analysis have been completed resulting in the identification of high risk components within the design. The design has been analyzed from a commercial and economic point of view and Cost of Energy (COE) calculations have been carried out with the potential to reduce COE by up to 18% when compared with a permanent magnet direct drive 5MW baseline machine, resulting in a potential COE of 0.075 $\$$/kWh. Finally, a top-level commercialization plan has been proposed to enable this technology to be transitioned to full volume production. The main body of this report will present the design processes employed and the main findings and conclusions.

17 WIND ENERGY↗