Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena

Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nanomechanical and Fluorescence Characterizations of Weathered PV Module Encapsulation

Nanoindentation and fluorescence spectroscopy provide spatially resolved mechanical and chemical characterization for degradation of poly (ethylene-co-vinyl acetate) (EVA) encapsulants aged under accelerated weathering and in field deployed photovoltaic (PV) modules. For the accelerated weathering tests, two different EVA formulations in the glass/EVA/glass-laminated coupons were exposed to ultraviolet (UV) light for 180 days at three different temperatures (40, 60, and 80 °C) and UV intensities (0.4, 2.2, and 2.9 W/m2/nm at 340 nm). The fluorescence spectra and moduli were uniform through the cross section of both EVA formulations at the lowest temperature and UV intensity; however, under the highest temperature and UV intensity, the UV irradiated sides showed lower moduli and higher fluorescence compared to the opposite sides. For EVA obtained from PV modules deployed 27 years in Sacramento, CA, USA, changes in fluorescence intensity across the thickness were relatively greater than changes in modulus. On the other hand, for EVA obtained from the same type of module stored in the shed for 27 years, no fluorescence was observed, and a uniform modulus was seen through the EVA layer, but with substantially higher values than those obtained from the field-deployed modules. The different extent of changes between laboratory and field exposures suggests the importance of considering effects of temperature and UV intensity for designing a reliable accelerated testing. This study uniquely demonstrates the capability of microscale characterization using nanoindentation and fluorescence microscopy to monitor mechanical and chemical degradation of EVA encapsulants in PV modules.

14 SOLAR ENERGY↗

Measurement of crack length in width tapered beam experiments

The width tapered beam method for measuring fracture toughness has been contemplated for use in measuring the adhesion of photovoltaic materials, is promoted by it being a viable method for use directly on modules rather than to engineered test specimens. However, precise determination of crack length is often difficult as failure often involves tendril formation, cavitation voids, and other plastic deformation at the crack front in addition to obfuscation by opaque materials. Because fracture energy varies as the square of crack length, imprecise crack tip length results in large measurement uncertainties. In this work, we develop a method to estimate the crack tip length using the relationship between the applied force and the displacement of the load frame. The crack tip is determined for every data point and can be defined from a calibration curve related to the amount of energy put into the beam, or from a theoretically idealized estimation. Once a calibration curve is set up and the equations programmed, the fracture energy as a function of position on the newly formed crack interface can be accurately estimated. The test additionally provides much easier analysis and insight into the joint failure through more precise knowledge of fracture toughness at each de-bonded area.

42 ENGINEERING↗

Characterization of Real-World and Accelerated Exposed PV Module Backsheet Degradation

Backsheet degradation is key to maintaining the lifetime of photovoltaic (PV) modules. Cracking, delamination, bubbling, and discoloration are main types of degradation. PV modules were collected from PV installations in multiple climatic zones. Multiple types of backsheets were obtained with poly(ethylene teraphlate) (PET) and polyamide air side layers being the largest number of backsheets retrieved. Multiple commercial PV backsheets were exposed to multiple accelerated exposures and key degradation mechanisms were identified. Polyamide backsheets showed cracking in retrieved modules and under accelerated exposures. Poly(vinylidene fluoride) (PVDF) and poly(vinyl fluoride) (PVF) showed the highest stability in retrieved and accelerated exposures. While polyamide had the largest amount of large scale degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part I: Field Modules

Photovoltaic backsheets are exposed to harsh outdoor weathering conditions throughout their service lives that can compromise their protective function, through adhesive debonding between their constituent layers and between the backsheet and the module. We report a large-scale study on adhesive degradation was conducted on 37 field-exposed modules, that spanned 19 different module manufacturers, that were deployed among six Köppen–Geiger climatic zones, and that were fielded between 0 and 28 years. Six outer layer polymer classes were identified among the backsheets: polyamide (PA), polyethylene terephthalate (PET), polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF), fluoroethylene vinyl ether copolymer (FEVE), and tetrafluoroethylene hexafluoropropylene vinylidene fluoride copolymer (THV). Two adhesion tests were used to measure the adhesive strength: the wedge test and the width-tapered single-cantilever beam (SCB) test. Adhesion energies were compared across exposure time and Köppen–Geiger climatic zone. Many of the PET-, PVF-, and PVDF-based backsheets experienced degradation of the adhesive layer between the backsheet outer and core layers. A consistent trend of decreasing adhesion energy with exposure time was observed in five out of the six backsheet types. Trends among adhesion energy and climatic zone, while expected, were not observed, possibly due to broad ranges in temperature, humidity, and precipitation defining Köppen–Geiger climatic zones. The cantilever beam measurements produced an upper cutoff of approximately 100 J/m 2 , above which no modules exhibited field delamination. The results are part of a two-part study quantifying adhesion in both field-weathered and indoor-exposed PV backsheets.

14 SOLAR ENERGY↗

Drivers for the cracking of multilayer polyamide‐based backsheets in field photovoltaic modules: In‐depth degradation mapping analysis

Abstract There is a lack of understanding on the root cause of cracking of photovoltaic (PV) backsheets due to the challenge of multilayer characterization and the complicated failure modes at the submodule level. In this work, the in‐depth degradation mapping of field‐exposed polyamide‐based (PA‐based) PV module backsheets was studied, with the major focus on the identification of underlying drivers for the through cracking (in between the solar cells). PV modules were retrieved from five different locations, comprising a variety of climates, including humid subtropical, hot‐summer Mediterranean, tropical savanna climate, and hot arid. A suite of microscale cross‐sectional characterizations, including chemical changes, fluorescence intensity, and modulus as a function of distance from the air surface of the backsheet, was performed. Results showed more advanced signs of degradation of the inner layer than the outer layer in the cracking region. Increases in the modulus were identified as the major indicator for the cracking. Moreover, a rudimentary test by immersion in acetic acid, which forms during photodegradation of the ethylene‐vinyl acetate copolymer (EVA) encapsulant, showed the first‐time direct evidence that acetic acid can largely accelerate the chemical degradation and facilitate the cracking of PA inner layer. This study suggests that the field cracking of PA‐based backsheet can be attributed to the combined effects of chemical degradation and physical reorganization (chemi‐crystallization) under cyclic thermomechanical stresses. Therefore, it is important to consider effects of local microclimates and interlayer infection to understand the heterogeneous nature of backsheet failures.

Lyu, Yadong↗

Impact of environmental variables on the degradation of photovoltaic components and perspectives for the reliability assessment methodology

Backsheet cracking has been a major issue observed in the field; however, standardized qualification tests, such as IEC61215, are inadequate to reliably identify such failures of PV modules due to the lack of the critical weathering factors applied sequentially or in combination, such as those found in the service environments. To address this problem, in this work we investigated the effects of various environmental variables on the degradation and failure behaviors of the polyamide-based backsheet in PV modules retrieved from five different locations, encompassing a variety of climates, including humid subtropical, hot-summer Mediterranean, tropical savanna climate and hot arid. The correlations between the degradation indicators and the weathering variables were further demonstrated by principle components analysis (PCA). We found strong relationships between: carbonyl formation and reflected solar radiation; hydroxyl formation and module temperature; yellowness and NO2 concentration, while no simple correlation could be found between a specific weathering factor and cracking. By introducing additional stress factors to the aged polyamide-based backsheet films with the novel 'fragmentation test', we successfully reproduced the field cracking behaviour. This study has demonstrated that different degradation modes of PV components respond differently to the environmental stresses encountered in service. Thereby, any accelerated laboratory test based on a single set condition or lacking key environmental variables would be inadequate to assess the long-term performance of PV modules and components. A new reliability-based methodology is proposed to quantitatively link laboratory testing with field results for the service life prediction of PV materials.

14 SOLAR ENERGY↗