Search NASA⌕ Search

Engineering topics

Fales, C. L., Jr.

Publications and source records attributed to Fales, C. L., Jr..

Wavelength error analysis in a multiple-beam Fizeau laser wavemeter having a linear diode array readout

An estimate of the wavelength accuracy of a laser wavemeter is performed for a system consisting of a multiple-beam Fizeau interferometer and a linear photosensor array readout. The analysis consists of determining the fringe position errors which result when various noise sources are included in the fringe forming and detection process. Two methods of estimating the fringe centers are considered: (1) maximum pixel current location, and (2) average pixel location for two detectors with nearly equal output currents. Wavelength error results for these two methods are compared for some typical wavemeter parameters.

Robinson, D. M.↗

Magnetometer with a miniature transducer and automatic scanning

The magnetometer is based on the time variation of the magnetic permeability in the magnetic material of its transducer; however, its operation is substantially different from the ordinary flux-gate magnetometer. The transducer uses 0.05 mm diameter plated magnetic wire and is made flat enabling it to make measurements of transverse magnetic fields as close as 0.08 mm from the surface, and it has very good spatial resolution because of its small active region of approximately 0.64 mm by 0.76 mm. The magnetometer uses an inexpensive clip-on millimeter for driving and processing the electrical signals and readout. It also utilizes an automatic scanning technique which is made possible by a specially designed transducer holding mechanism that replaces the ink pen on an X-Y recorder.

Debnam, W. J. J.↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗

An analysis of the facsimile-camera response to radiant point sources

In addition to imaging the surrounding terrain, planetary lander cameras may also be used to survey the stars to aid in locating the lander site. The response of the facsimile camera, which was selected for the Viking lander missions to Mars, to a radiant point source is formulated and shown to result in a statistical rather than deterministic signal. The signal statistics are derived and magnitudes are evaluated for the brighter visual and red stars. The probability of detecting the resultant statistical signals in photosensor and preamplifier noise and the associated probability of false alarms are also determined.

Huck, F. O.↗

Proton-radiation damage in Gunn oscillators

The irradiation effects of 22 MeV protons on the electrical characteristics of GaAs continuous-wave Gunn oscillators was studied. The radio frequency power output was reduced by 3 decibels at proton fluences in the neighborhood of 1.5 x 10 to the 12th power protons/sq cm. Conductance measurements indicate that the carrier removal rate at high electric fields remained roughly 40 percent less than at low fields. Diode efficiencies of two device groups were found to be monotonically descreasing functions of fluence. Frequency modulation noise was generally unaffected by radiation, but the magnitude of the noise in the noise power spectrum increased significantly. These effects are partially accounted for, in a qualitative fashion, by a model of electron traps having field-dependent net-carrier capture rates and various response times.

Johnson, J. W.↗