Search NASA⌕ Search

Engineering topics

Fan, D.

Publications and source records attributed to Fan, D..

Modelling low Mach number stellar hydrodynamics with MAESTROeX

Modelling long-time convective flows in the interiors of stars is extremely challenging using conventional compressible hydrodynamics codes due to the acoustic timestep limitation. Many of these flows are in the low Mach number regime, which allows us to exploit the relationship between acoustic and advective time scales to develop a more computationally efficient approach. MAESTROeX is an open source low Mach number stellar hydrodynamics code that allows much larger timesteps to be taken, therefore enabling systems to be modelled for much longer periods of time. This is particularly important for the problem of convection in the cores of rotating massive stars prior to core collapse. To fully capture the dynamics, it is necessary to model these systems in three dimensions at high resolution over many rotational periods. We present an overview of MAESTROeX's current capabilities, describe ongoing work to incorporate the effects of rotation and discuss how we are optimising the code to run on GPUs.

Harpole, A.↗

Dynamic shear localization of a titanium alloy under high-rate tension characterized by x-ray digital image correlation

Highlights: • First systematic error analyses for XDIC • First XDIC study of Ti-6Al-4V under dynamic tension • Deformation mode transition induces dynamic ductility decrease. • Dynamic shear localization due to rate-dependent microvoid coalescence process. - Abstract: Dynamic and quasi-static tension experiments are conducted on Ti-6Al-4V alloys, with in situ, synchrotron-based, high-speed, x-ray phase contrast imaging implemented to characterize the dynamic deformation and fracture process of Ti alloys at the Advanced Photon Source. X-ray digital imaging correlation (XDIC) is applied for strain field mapping. The size distribution of x-ray speckles are quantified via a morphological analysis, with a mean of ∼20 μm. Systematic error analyses of displacement and strain field measurements are firstly conducted for XDIC, and demonstrate that the displacement and strain errors can be controlled below 0.01 pixel and 0.1%, respectively. Mesoscale strain characteristics measured via XDIC are consistent with and reveal mechanisms for the bulk-scale stress–strain responses. Under dynamic tension, a sharp transition to strain softening occurs when the bulk strain exceeds about 0.04, which leads to a lower dynamic fracture strain (0.08) than the quasi-static one (0.1). The corresponding strain filed mapping demonstrates that shear deformation localizations grow and coalesce rapidly into a narrow shear deformation band under dynamic loading, while tensile deformation and necking progresses gradually under quasi-static loading. Scanning electron microscopy shows that void nucleation occurs mainly at the interface of α and β phases for both quasi-static and dynamic tension. However, microvoids coalesce preferentially along colony boundaries or the boundary α phase under quasi-static tension, but along the maximum shear stress direction (across colonies) under dynamic tension. Fractography of recovered samples also shows consistent features.

36 MATERIALS SCIENCE↗

Anisotropic deformation of extruded magnesium alloy AZ31 under uniaxial compression: A study with simultaneous in situ synchrotron x-ray imaging and diffraction

In situ synchrotron x-ray imaging and diffraction are used to investigate anisotropic deformation of an extruded magnesium alloy AZ31 under uniaxial compression along two different directions, with the loading axis (LA) either parallel or perpendicular to the extrusion direction (ED), referred to as LA∥ED and LAED, respectively. Multiscale measurements including stress–strain curves (macroscale), x-ray digital image correlation (mesoscale), and diffraction (microscale) are obtained simultaneously. Electron backscatter diffraction is performed on samples collected at various strains to characterize deformation twins. The rapid increase in strain hardening rate for the LA∥ED loading is attributed to marked {101¯2} extension twinning and subsequent homogenization of deformation, while dislocation motion leads to inhomogeneous deformation and a decrease in strain hardening rate.

36 MATERIALS SCIENCE↗

Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic tensile deformation and damage of B 4 C-reinforced Al composites: Time-resolved imaging with synchrotron x-rays

Dynamic tensile experiments are conducted on 15% and 30% in weight percentage B 4 C/Al composites with a split Hopkinson tension bar, along with high-speed synchrotron x-ray digital image correlation (XDIC) to map strain fields at μ m and μ s scales. As manifested by bulk-scale stress – strain curves, a higher particle content leads to a higher yield strength but lower ductility. Strain field mapping by XDIC demonstrates that tension deformation and tensile fracture, as opposed to shear and shear failure, dominate deformation and failure of the composites. The fractographs of recovered samples show consistent features. The particle-matrix interfaces are nucleation sites for strain localizations, and their propagation and coalescence are diffused by the Al matrix. The reduced spacing between strain localization sites with increasing particle content, facilitates their coalescence and leads to decreased ductility. Furthermore, designing a particle-reinforced, metallic-matrix composite with balanced strength and ductility should consider optimizing the inter-particle distance as a key par

36 MATERIALS SCIENCE↗

Transient x-ray diffraction with simultaneous imaging under high strain-rate loading

Real time, in situ, multiframe, diffraction, and imaging measurements on bulk samples under high and ultrahigh strain-rate loading are highly desirable for micro- and mesoscale sciences. We present an experimental demonstration of multiframe transient x-ray diffraction (TXD) along with simultaneous imaging under high strain-rate loading at the Advanced Photon Source beamline 32ID. The feasibility study utilizes high strain-rate Hopkinson bar loading on a Mg alloy. The exposure time in TXD is 2–3 μs, and the frame interval is 26.7–62.5 μs. Various dynamic deformation mechanisms are revealed by TXD, including lattice expansion or compression, crystal plasticity, grain or lattice rotation, and likely grain refinement, as well as considerable anisotropy in deformation. Dynamic strain fields are mapped via x-ray digital image correlation, and are consistent with the diffraction measurements and loading histories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Dynamic strain field mapping with synchrotron X-ray digital image correlation

We present a dynamic strain field mapping method based on synchrotron X-ray digital image correlation (XDIC). Synchrotron X-ray sources are advantageous for imaging with exceptional spatial and temporal resolutions, and X-ray speckles can be produced either from surface roughness or internal inhomogeneities. Combining speckled X-ray imaging with DIC allows one to map strain fields with high resolutions. Based on experiments on void growth in Al and deformation of a granular material during Kolsky bar/gas gun loading at the Advanced Photon Source beamline 32ID, we demonstrate the feasibility of dynamic XDIC. XDIC is particularly useful for dynamic, in-volume, measurements on opaque materials under high strain-rate, large, deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A metallography and x-ray tomography study of spall damage in ultrapure Al

We characterize spall damage in shock-recovered ultrapure Al with metallography and x-ray tomography. The measured damage profiles in ultrapure Al induced by planar impact at different shock strengths, can be described with a Gaussian function, and showed dependence on shock strengths. Optical metallography is reasonably accurate for damage profile measurements, and agrees within 10–25% with x-ray tomography. Full tomography analysis showed that void size distributions followed a power law with an exponent of γ = 1.5 ± 2.0, which is likely due to void nucleation and growth, and the exponent is considerably smaller than the predictions from percolation models.

36 MATERIALS SCIENCE↗

Low temperature magneto-photoluminescence of GaAsBi /GaAs quantum well heterostructures

Strong optical anisotropy is observed in the emission from a GaAs{sub 1−x}Bi{sub x} (x ∼ 0.04) quantum well grown by low temperature molecular beam epitaxy on (001) GaAs by means of low temperature magneto-photoluminescence (MPL) taken at 2 K in Faraday geometry for magnetic fields, B, up to 10 T. A significant diamagnetic shift (∼2.5 meV) develops for magnetic fields above ∼8 T, which is accompanied by a narrowing of the emission bandwidth and a substantial increase in the difference between the integrated intensities of the σ{sup +} and σ{sup −} polarizations in the MPL spectra. This, along with a peculiar spectral dependence of the polarization degree which evolves with increasing magnetic field, is interpreted in terms of bound and free magneto excitons in the system where Bi-related levels become hybridized to different extents with the valence and conduction bands of the GaAs host material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Phase retrieval method for analyzing single-phase displacement interferometry data

We present a phase retrieval method (PRM) for analyzing single-phase displacement interferometry measurements on rapidly changing velocity histories, including photon Doppler velocimetry (PDV). PRM identifies the peaks and valleys as well as zero-crossing points in a PDV time series, performs normalization and extracts point-by-point phase and thus velocity information. PRM does not require a wide time window as in sliding window Fourier transformation, and thus improves the effective temporal resolution. This method is implemented in analyzing PDV data obtained from gas gun experiments, and validated against simultaneous measurements with velocity interferometer system for any reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of atmospheric parameters on radon measurements using alpha-track detectors

The calibration factors of alpha-track radon detectors (ATDs) are essential for accurate determination of indoor radon concentrations. In this paper, the effects of atmospheric parameters on the calibration factors were theoretically studied and partially testified. Based on the atmospheric thermodynamics theory and detection characteristics of the allyl diglycol carbonate (CR-39), the calibration factors for 5 types of ATDs were calculated through Monte Carlo simulations under different atmospheric conditions. Simulation results showed that the calibration factor increased by up to 31% for the ATDs with a decrease of air pressure by 35.5 kPa (equivalent to an altitude increase of 3500 m), and it also increased by up to 12% with a temperature increase from 5 °C to 35 °C, but it was hardly affected by the relative humidity unless the water-vapor condensation occurs inside the detectors. Furthermore, it was also found that the effects on calibration factors also depended on the dimensions of ATDs. It indicated that variations of the calibration factor with air pressure and temperature should be considered for an accurate radon measurement with a large dimensional ATD, and water-vapor condensation inside the detector should be avoided in field measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗