Search NASA⌕ Search

Engineering topics

Fan, Lingling

Publications and source records attributed to Fan, Lingling.

47 records · Page 3

Identifying DQ-Domain Admittance Models of a 2.3-MVA Commercial Grid-Following Inverter Via Frequency-Domain and Time-Domain Data

Here, we present two methods to identify the admittance of a 2.3-MVA commercial grid-following inverter through frequency-domain data and time-domain data. In addition to the well-known harmonic injection method to obtain the admittance at frequency points followed by vector fitting, we adopt a step response-based method where the step response data of the converter are collected and their s-domain expressions are obtained. In turn, the s-domain admittance model of the converter is found. The two methods can be used for cross validation. Step responses and frequency-domain responses obtained from the two methods are compared. Results show that the time- domain data-based method leads to an admittance comparable with that from the frequency-domain measurement in the range less than 60 Hz. In addition, two insights are obtained from the frequency-domain admittance measurements. First, when the dq- frame is aligned to the point of common coupling (PCC) voltage, the per unit DQ-domain admittance directly reflects operating conditions. Second, existence of negative-sequence control can be detected via sequence-domain admittances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Stability Definitions, Analysis, and Examples

This document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid Stability Definitions, Analysis, and Modeling [1], which defines concepts and identifies relevant issues related to stability in microgrids. In this paper, definitions and classification of microgrid stability are presented and discussed, considering pertinent microgrid features such as voltage-frequency dependency, unbalancing, low inertia, and generation intermittency. A few examples are also presented, highlighting some of the stability classes defined in the paper. Further examples, along with discussions on microgrid components modeling and stability analysis tools can be found in the TF report.

Farrokhabadi, Mostafa↗

Dynamic parameter estimation of generators

Various examples are provided for parameter estimation of generators. In one example, among others, a method includes collecting data corresponding to a generator using a phasor management unit (PMU) and estimating dynamic parameters of the generator using extended Kalman filtering (EKF) and the collected PMU data. In another example, a system includes at least one application executable in a processing device that obtains operational data corresponding to a generator and estimates a dynamic parameter of the generator using EKF and the operational data. In another example, an EKF estimator includes a dynamics estimator configured to estimate a state variable of a generator, a geometry estimator configured to estimate phasor values associated with the generator, and a Kalman filter gain configured to determine a correction to the state variable.

Miao, Zhixin↗

Synchronous generator modeling and frequency control using unscented Kalman filter

Various examples are related to synchronous generator modeling with frequency control, which can be achieved using unscented Kalman filtering. In one example, a method includes obtaining operational parameters associated with a generator of a power system; determining parameters of a synchronous generator model with frequency control based at least in part upon the operational parameters associated with the generator; and providing a command to a frequency control of the generator, the command updating one or more parameters of the frequency control. In another example, a system includes a generator controller for a generator of a power system; and a computing device in communication with the generator controller, where the computing device is configured to determine parameters of the synchronous generator model using operational parameters associated with the generator and provide a command updating one or more parameters of a frequency control of the generator controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗