Search NASA⌕ Search

Engineering topics

Farooque, M.

Publications and source records attributed to Farooque, M..

Corrosion of graphite composites in phosphoric acid fuel cells

Polymers, polymer-graphite composites and different carbon materials are being considered for many of the fuel cell stack components. Exposure to concentrated phosphoric acid in the fuel cell environment and to high anodic potential results in corrosion. Relative corrosion rates of these materials, failure modes, plausible mechanisms of corrosion and methods for improvement of these materials are investigated.

Christner, L. G.↗

Methodology for predictive testing of fuel cells

A perturbation testing method has been developed and tested for predictive testing of fuel cells. This method involves application of small changes to the operating conditions of the cell in a predetermined sequence. The resultant response of the cell is then measured and statistically correlated with the corresponding test conditions. This method has been applied to the phosphoric acid fuel cell, and the effect of operating and cell-component variables on cell-performance degradation has been studied. A strong effect of the cell temperature and cathode potential on fuel-cell-performance degradation has been observed. A cell-performance degradation model has been formulated, and the unknown parameters in the model have been estimated by a regression analysis of the experimental data. A reasonable agreement between the fuel cell performance predicted by this model (derived from the perturbation experiments) and the unperturbed test data supports fthe applicability of the perturbation method.

Patel, D. N.↗

Evaluation of gas cooling for pressurized phosphoric acid fuel cell stacks

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas cooling has already been demonstrated in atmospheric pressure stacks. This paper presents theoretical and experimental investigation of gas cooling for pressurized PAFC. Two approaches to gas cooling, Distributed Gas Cooling (DIGAS) and Separated Gas Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Farooque, M.↗

Evaluation of distributed gas cooling of pressurized PAFC for utility power generation

Two short stacks were pressure tested at 446 kPa (4.4 atm.) and the pressure gains were more than the theoretically predicted gains. Temperature profiles were observed to be independent of operating pressure. The pressure drop was found to be inversely proportional to operating pressure as expected. Continuous pressurized operation of a stack for 1000 hours verified the compatability of the fuel cell component design. A simple pressurization procedure was also developed. Six separate designs, covering two gas cooling schemes (DIGAS and separated) and two cooling channel geometries (straight through and treed), were analysed on the net voltage output basis. Separated cooling with 5 cells per cooler was recognized to be the best among the designs considered.

Farooque, M.↗