Search NASA⌕ Search

Engineering topics

Fast, J. E.

Publications and source records attributed to Fast, J. E..

At least 19 records

Dalitz analysis of $D^0 → K^–π^+η$ decays at Belle

We present the results of the first Dalitz plot analysis of the decay D 0 → K – π + η . The analysis is performed on a data set corresponding to an integrated luminosity of 953 fb – 1 collected by the Belle detector at the asymmetric-energy e + e – KEKB collider. The Dalitz plot is well described by a combination of the six resonant decay channels K ¯ * ( 892 ) 0 η , K – a 0 ( 980 ) + , K – a 2 ( 1320 ) + , K ¯ * ( 1410 ) 0 η , K * ( 1680 ) – π + and K 2 * ( 1980 ) – π + , together with K π and K η S-wave components. The decays K * ( 1680 ) – → K – η and K 2 * ( 1980 ) – → K – η are observed for the first time. We measure ratio of the branching fractions, B ( D 0 → K – π + η ) B ( D 0 → K – π + ) = 0.500 ± 0.002 ( stat ) ± 0.020 ( syst ) ± 0.003 ( B PDG ) . Using the Dalitz fit result, the ratio B ( K * ( 1680 ) → K η ) B ( K * ( 1680 ) → K π ) is measured to be 0.11 ± 0.02 ( stat ) – 0.04 + 0.06 ( syst ) ± 0.04 ( B PDG ) ; this is much lower than the theoretical expectations ( ≈ 1 ) made under the assumption that K * ( 1680 ) is a pure 1 3 D 1 state. The product branching fraction B ( D 0 → [ K 2 * ( 1980 ) – → K – η ] π + ) = ( 2. 2 – 1.9 + 1.7 ) × 10 – 4 is determined. In addition, the π η ' contribution to the a 0 ( 980 ) ± resonance shape is confirmed with 10.1 σ statistical significance using the three-channel Flatté model. We also measure B ( D 0 → K ¯ * ( 892 ) 0 η ) = ( 1.4 1 – 0.12 + 0.13 ) % . This is consistent with, and more precise than, the current world average ( 1.02 ± 0.30 ) % , deviates with a significance of more than 3 σ from the theoretical predictions of (0.51–0.92)%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Migration of noble gas tracers at the site of an underground nuclear explosion at the Nevada National Security Site

As part of an underground gas migration study, two radioactive noble gases and two stable tracer gases were injected into a nuclear explosion test chimney and allowed to migrate naturally. Soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 meters) to deeper levels (~160 meters) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.

Johnson, Christine M.↗