Search NASA⌕ Search

Engineering topics

Fava, A.

Publications and source records attributed to Fava, A..

At least 19 records

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

Review of Particle Physics - Scalar Mesons below 1 GeV

The summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,717 new measurements from 869 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 120 reviews are updated, including many that are heavily revised. The is divided into two volumes. Volume 1 includes the Summary Tables and 97 review articles. Volume 2 consists of the Particle Listings and contains also 23 reviews that address specific aspects of the data presented in the Listings. The complete (both volumes) is published online on the website of the Particle Data Group () and in a journal. Volume 1 is available in print as the . A with the Summary Tables and essential tables, figures, and equations from selected review articles is available in print, as a web version optimized for use on phones, and as an Android app. The 2024 edition of the Review of Particle Physics should be cited as: S. Navas et al. (Particle Data Group), Phys. Rev. D 110, 030001 (2024)© 20242024

Navas, S. [Universidad de Granada]↗

Search for inelastic boosted dark matter with the ICARUS detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton · year , collected by the ICARUS T-600 detector during its 2012–2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multiparticle dark sector with a U ( 1 ) ′ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature that consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ( m X , ε ) parameter space for several selected optimal boosted dark matter mass sets and cover previously unexplored parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics Opportunities at a Beam Dump Facility at PIP-II at Fermilab and Beyond

The Fermilab Proton-Improvement-Plan-II (PIP-II) is being implemented in order to support the precision neutrino oscillation measurements at the Deep Underground Neutrino Experiment, the U.S. flagship neutrino experiment. The PIP-II LINAC is presently under construction and is expected to provide 800~MeV protons with 2~mA current. This white paper summarizes the outcome of the first workshop on May 10 through 13, 2023, to exploit this capability for new physics opportunities in the kinematic regime that are unavailable to other facilities, in particular a potential beam dump facility implemented at the end of the LINAC. Various new physics opportunities have been discussed in a wide range of kinematic regime, from eV scale to keV and MeV. We also emphasize that the timely establishment of the beam dump facility at Fermilab is essential to exploit these new physics opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The scintillation light detection system of ICARUS-T600: Hardware implementation and early results

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is taking data with the Fermilab Booster Neutrino Beam-line (BNB) in the Short Baseline Neutrino (SBN) program to search for a possible LSND-like sterile neutrino signal. A light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs) deployed behind the TPC wire chambers, has been realized to detect vacuum ultraviolet (VUV) photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SBN-BD: O(10 GeV) Proton Beam Dump at Fermilab’s PIP-II Linac

Proton beam dumps are prolific sources of mesons enabling a powerful technique to search for vector mediator coupling of dark matter to neutral pion and higher mass meson decays. By the end of the decade the PIP-II linac will be delivering up to 1 MW of proton power to the FNAL campus. This includes a significant increase of power to the Booster Neutrino Beamline (BNB) which delivers 8 GeV protons to the Short Baseline Neutrino (SBN) detectors. By building a new dedicated beam dump target station, and using the SBN detectors, a greater than an order of magnitude increase in search sensitivity for dark matter relative to the recent MiniBooNE beam dump search can be achieved. This modest cost upgrade to the BNB would begin testing models of the highly motivated relic density limit predictions and provide novel ways to test explanations of the anomalous excess of low energy events seen by MiniBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SBN-BD: $\mathcal{O}$(10 GeV) Proton Beam Dump at Fermilab's PIP-II Linac

Proton beam dumps are prolific sources of mesons enabling a powerful technique to search for vector mediator coupling of dark matter to neutral pion and higher mass meson decays. By the end of the decade the PIP-II linac will be delivering up to 1 MW of proton power to the FNAL campus. This includes a significant increase of power to the Booster Neutrino Beamline (BNB) which delivers 8 GeV protons to the Short Baseline Neutrino (SBN) detectors. By building a new dedicated beam dump target station, and using the SBN detectors, a greater than an order of magnitude increase in search sensitivity for dark matter relative to the recent MiniBooNE beam dump search can be achieved. This modest cost upgrade to the BNB would begin testing models of the highly motivated relic density limit predictions and provide novel ways to test explanations of the anomalous excess of low energy events seen by MiniBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ICARUS: new voyage to sterile neutrino search in the Short Baseline Program

The ICARUS collaboration operated the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratories studying neutrino oscillations with the CNGS neutrino beam from CERN, and searching for atmospheric neutrino interactions. ICARUS performed a sensitive search for LSND-like anomalous νe appearance in the CNGS beam, which contributed to the constraints on the allowed parameters to a narrow region around $Δm^2=1 e\text{V}^2$, where all the experimental results can be coherently accommodated at 90% C.L. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS has started operations and is presently in its commissioning phase with the aim of collecting its first neutrino events from the Booster Neutrino Beam and the NuMI off-axis beam. The main goal of the first year of ICARUS data taking will then be the definitive verification of the recent claim by NEUTRINO-4 short baseline reactor experiment both in the $ν_μ$ channel with the BNB and in the $ν_e$ with NuMI. After the first year of operations, ICARUS will commence its search for evidence of a sterile neutrino jointly with the SBND near detector, within the Short Baseline Neutrino (SBN) program. The ICARUS exposure to the NuMI beam will also give the possibility for other physics studies such as light dark matter searches and neutrino-Argon cross section measurements. The proposed contribution addresses ICARUS achievements, its status and plans for the new run at Fermilab and the ongoing developments of the analysis tools needed to fulfill its physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overhaul and installation of the ICARUS-T600 liquid argon TPC electronics for the FNAL Short Baseline Neutrino program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016–2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗