Search NASA⌕ Search

Engineering topics

Feagin, Trevor Alexander

Publications and source records attributed to Feagin, Trevor Alexander.

Weak shock compaction on granular salt

This study conducted integrated experiments and computational modeling to investigate the speeds of a developing shock within granular salt and analyzed the effect of various impact velocities up to 245 m/s. Experiments were conducted on table salt utilizing a novel setup with a considerable bore length for the sample, enabling visualization of a moving shock wave. Experimental analysis using particle image velocimetry enabled the characterization of shock velocity and particle velocity histories. Mesoscale simulations further enabled advanced analysis of the shock wave’s substructure. In simulations, the shock front’s precursor was shown to have a heterogeneous nature, which is usually modeled as uniform in continuum analyses. The presence of force chains results in a spread out of the shock precursor over a greater ramp distance. With increasing impact velocity, the shock front thickness reduces, and the precursor of the shock front becomes less heterogeneous. Furthermore, mesoscale modeling suggests the formation of force chains behind the shock front, even under the conditions of weak shock. This study presents novel mesoscale simulation results on salt corroborated with data from experiments, thereby characterizing the compaction front speeds in the weak shock regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IHE DDT Qualification Tests (FY2020-FY2021)

A DDT tube test was designed to meet all requirements established in the new DOE IHE qualification standard. Ten tests were successfully executed with PBX 9502 as a demonstration of the design, assembly, heating system, and methods, and to establish a baseline set of test results with an existing IHE. The explosive response in all tests was low violence (as anticipated). This report contains detailed design drawings, assembly instructions and procedures for future execution of the qualification test series, and makes recommendations for minor improvements.

42 ENGINEERING↗

Time-resolved nanosecond optical pyrometry of the vapor to plasma transitions in exploding bridgewires

Electrically exploded wires find uses throughout high-energy physics. For example, they are commonly used as high-temperature sources, X-ray generators, and in precision timing detonators. However, the detailed and complete physics that occurs is complex and still poorly understood. A full mechanistic description of these complex phenomena is beyond the scope of a single paper. Instead, we focus on the formation of metal vapor and its transition to plasma. This single transition is commonly assumed to comprise “bridge-burst”. We use a suite of diagnostics including a novel, fiber-based, high-speed, optical pyrometer to better characterize this transition. The primary finding from this project is that peak light output from an exploding wire does not temporally match the peak temperature. Additionally, it is found that peak light does not align with peak bridge-burst voltage and that the peak temperature is not voltage-dependent. These findings are non-intuitive and will allow for the correction of false assumptions previously made about this topic.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CISME report on experiments with HMX powder, PBX 9501 prills, and heated PBX 9501

The ability to predict post-ignition explosive response is relevant to explosives safety, particularly weapons assembly/disassembly operations that must operate under a sufficiently conservative safety basis to meet risk mitigation criteria for inadvertent nuclear detonation (IND). In particular, hazard determinations hinge on whether the PBX 9501 main charge can ultimately attain detonation from an initial, non-shock, ignition stimulus. The CISME experiment uses a spherical explosive charge, which is thermally ignited in the center using a fiber-delivered infrared laser pulse. This ignition mechanism - i.e. a localized thermal hotspot - is representative of the ignition-causing insults typical in accident scenarios, including low-velocity impact, drop, skid, and punch events. In fiscal year 2018 CISME experiments were conducted with pristine PBX 9501 spheres, confined and unconfined. Sub-detonative, low-violence reactions were observed. Here we report experiments conducted since 2018. The explosive charge was varied: experiments were conducted with room temperature pour-density HMX powder and prills of PBX 9501, and heated, thermally damaged PBX 9501. Experiments were conducted in a confined configuration, with two 4 mm-thick stainless-steel hemispherical shells bolted around the sphere. Detonation, via DDT (deflagration-to-detonation transition) was observed in the 3-inch diameter powdered HMX and the 6-inch diameter heated and thermally-damaged PBX 9501 tests. No transition to DDT was observed in smaller diameters for those configurations, and no DDT was observed for pour-density prills of PBX 9501 of any diameter. The original test series demonstrated that the response of pristine, undamaged PBX 9501 to a central ignition is relatively benign. This new test series shows that increased porosity, lack of polymer binders and thermal damage can greatly increase the violence of the post-ignition response, up to and including detonation. These results bridge the explosive response of PBX 9501 from sub-detonative through detonation as a function of diameter and provide valuable test cases for modeling efforts that strive to capture the DDT threshold. By exploring explosive response in a more representative 3D geometry, we can also benchmark these new results to more plentiful DDT datasets generated from testing in 1D tube confinement (the historical test configuration)–the configuration upon which almost all DDT models were developed.

42 ENGINEERING↗

Heavily Confined PBX 9501 Experiment Report FY2020

Most accidental insults to explosives are invariably thermal in nature—either direct thermal via application of heat or indirect thermal when mechanical energy is converted to heat. The key question is whether the initial thermal insult transitions into a violent explosive response. If the ultimate violence attained is moderate, nearby personnel may be harmed or killed, but Inadvertent Nuclear Detonation (IND) will not occur. However, if the explosive ultimately transitions from deflagration to detonation (DDT) then IND becomes a concern. PBX 9501 is not an insensitive high explosive (IHE). It has been conclusively demonstrated that mechanically and thermally damaged PBX 9501 can readily DDT in heavy confinement. However, it is currently unknown whether pristine explosive—i.e. thermally and mechanically undamaged— is capable of DDT. Three experiments were conducted in order to determine whether very heavily confined pristine PBX 9501 is capable of DDT. All experiments used identical 6-inch diameter spherical charges of PBX 9501 confined in a 350 lb. hardened steel vessel with >2.5-inch thick walls. The first, primary experiment tested pristine PBX 9501 and was thermally ignited at the center of using a laser over optical fiber. Two additional baseline experiments were performed for comparison: the second test was initiated at the center using a detonator; the third test was bulk heated until self-ignition (cookoff). Velocimetry data in combination with hydrocode simulations suggest that a classical detonation wave did not develop in the pristine, thermally ignited PBX 9501. Reaction violence was approximately equivalent—in terms of ultimate energy output—as a full detonation, but the acceleration of metal fragments occurred more slowly than in a detonation-driven scenario.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Investigating the minimum post-burst energy required to function an exploding bridgewire detonator

The minimum energy required after bridge-burst to function a commercially available RP-1 exploding bridgewire detonator with a gold bridgewire was investigated using two capacitor discharge units (CDUs) making use of state-of-the-art on/off high-voltage high-current switches. Both switches are capable of shutting off the current flow in ≈100ns and the conduction time was varied systematically to limit the duration of electrical energy delivered from the CDU until a detonation go/no-go threshold was reached. It was found that the minimal extra electrical energy required for a soft-fire (a statistically marginal go) was approximately half that required for a hard-fire (a definite go). Furthermore, the measured energy required to function the RP-1 detonator from the 11.5 kV CDU was approximately 20 mJ greater than for the 600 V CDU, and it is postulated that this was due to arcing across the detonator terminals and an associated current shunt that was not efficient at depositing energy conducive to detonator functioning. Measurements of the bridgewire temperatures bursting in air showed that the maximum temperature reached was consistent (≈18kK) when sufficient energy was delivered that the detonator functioned (either soft- or hard-fire), but that the temperature for a sub-threshold bridgewire burst was significantly cooler at approximately 8 kK. Furthermore, it was demonstrated that the intensity of the light emitted at burst scaled with deposited energy. A related finding is that the light emission from the bridgewire peaks some tens of nanoseconds after both peak voltage and peak electrical power.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Deflagration-to-Detonation Transition in Two Dimensions

The Deflagration-to-Detonation Transition (DDT) in one-dimensional porous explosive, where combustion in an explosive transitions to detonation, can be described by the following model. This simplified model proceeds in five steps, as follows: 1) Ignition of the explosive, surface burning. 2) Convective burning, with the flame front penetrating through the porous network of the explosive. This proceeds until the pressure grows high enough to result in choked flow in the pores restricting the convective burn. 3) The choked flow results in the formation of a high-density compact of explosive. This compact is driven into undisturbed material by the pressure of the burning explosive. 4) The compression of the undisturbed porous explosive by the compact leads to the ignition of a compressive burn. This builds in pressure until a supported shock forms. 5) The shock builds in pressure until detonation occurs. See Figures 1 and 2 for an overview of the proceeding steps. It has been assumed in the past that the same mechanism which drives DDT in the one dimensional case will apply to both two and three dimensions. However, this has never been experimentally verified and it is possible that an entirely new mechanism drives DDT higher dimensions. In order to test this a series of two dimensional DDT tests were performed to help provide empirical evidence of the mechanism in higher dimensions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optical absorption in polycrystalline PETN, RDX, HMX, CL-20 and HNS and its possible effect on exploding bridgewire detonator function

Exploding bridgewire (EBW) detonators work by bursting a thin conducting wire as a result of a high voltage discharge. This process is known to produce a strong UV emission. In this work, the roles of optical absorption, photochemistry, shock sensitivity, and impact sensitivity are assessed with respect to the relative roles each plays in the operation of an EBW detonator. The optical absorptivity and penetration depth have been measured using dilute polycrystalline samples of PETN, RDX, HMX, CL-20 and HNS in KBr between 190 and 1100 nm. The results show strong absorption at UV wavelengths with a gradual decline at longer ones. It is found that while strong UV absorption appears to be necessary, it is not sufficient to make an effective EBW detonator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On The Deflagration to Detonation Transition in 1.65 g cm -3 Pentaerythritol Tetranitrate

The LANL Weapons Response Group is charged with making determinations for a wide range of scenarios regarding the probability that inadvertent ignition of the high explosive (HE) components might cause nuclear yield, or dispersal of special nuclear material, during assembly/disassembly operations at the Pantex Plant. These scenarios are categorized based on the nature of the ignition causing stimulus, i.e. impact, electrostatic discharge, pressure-shear, etc. However, for all of these scenarios, regardless of how ignition is achieved, there must also be a credible path for the burning HE to transition to detonation for yield or dispersal to occur. If it can be determined that there is no feasible path for deflagration-to-detonation transition (DDT), the scenario space that requires mitigative action is greatly reduced. The strategy to support Weapons Response determinations is to use experimentation and observation to evaluate HE response in severe “overtest” configurations. To increase with confidence in the margins of HE response, these overtests are designed, by controlling parameters known to enhance HE response violence, to be more severe than what is ever encountered in the actual operations environment at the Plant. This study is focused on DDT in pentaerythritol tetranitrate (PETN), a high explosive that is used in LANL’s detonators. PETN is known to be able to DDT at certain densities, and this represents a safety concern. The PETN in LANL’s detonators is commonly a density of 1.65 g cm -3 . However, DDT has never been observed at this density in PETN. In this work, we studied the DDT reaction in 1.65 g cm -3 PETN to determine whether DDT is possible at this density, and if so, what length of PETN is required for the transition to occur. In any of the tests conducted, we did not observe DDT in 1.65 g cm -3 PETN. It is possible that the DDT length for 1.65 g cm -3 PETN is greater than 6” (the available run length in the experiments), but this length is simply not available in a detonator, and is therefore not a concern.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Center-Ignited Spherical-Mass Explosion (CISME); FY 2018 Report

It is not known whether pristine (i.e. mechanically and thermally undamaged) PBX 9501 can transition from a deflagration to a detonation in realistic scenarios, with relevant charge masses and inertial and mechanical confinement. In order to place bounds on the behavior, a series of experiments was conducted in which a spherical PBX 9501 charge is center-ignited using a fiber-delivered infrared laser pulse. Charge diameter was varied from 1.5 in ch to 10 inch. Experiments were conducted in a “bare” (unconfined) configuration, and a confined configuration with 4 mm-thick stainless-steel hemispherical shells bolted together. In all eight experiments, the reaction exhibited a relatively benign pressure burst; no transition to detonation (DDT) was observed. Most of the explosive was unconsumed and recovered post-test. Confined tests demonstrated slightly greater violence than unconfined tests, as anticipated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fracture Effects on Explosive Response (FEER); FY2018 Report

It is known that the violence of explosive response is affected by inertial and mechanical confinement. In a mechanical insult, the impact location creates a contact pressure that can act as confinement surrounding the ignition location, as has been observed in the Skid Test experiment. Under certain conditions — the details of which have not been well characterized — the ignition can produce cracking in the explosive, down which flames are observed to propagate. Cracks serve to simultaneously provide additional surface area for accelerating the reaction, as well as vent paths for quenching the reaction. These are competing behaviors, and the factors which govern the outcome are poorly described. A new experiment was devised to examine the effect of a controlled pre-load pressure on the explosive response. Sixteen experiments were performed on 1-inch thick discs of PBX 9501, with diameters of 1 in ch, 4.25 in ch, and 5 in ch. The explosive was compressed to a known pre-load between two clear windows and ignited at the center of the bottom surface with a focused laser impinging on a graphite inclusion. The ensuing reaction was imaged through the windows used to compress the sample, and from the side. A speckle pattern was applied to some samples for performing DIC (digital image correlation) for the purpose of quantifying the strain field and tracking crack growth. A threshold behavior was observed, in which higher-pressure pre-load resulted in cracks forming, while lower-pressure pre-load vented across the face of the explosive. This report presents the preliminary results, discusses the observations, enumerates hypotheses regarding the observed behavior, identifies lessons learned, and outlines a path forward for the next round of testing. Proof testing was only recently concluded and considerable additional analysis is required. These data will be valuable for the ongoing development of a constitutive mechanical and cracking failure model that will aid in predicting explosive response in mechanical impact scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗