Search NASA⌕ Search

Engineering topics

Feng, Yi

Publications and source records attributed to Feng, Yi.

Synthesis pathways to thin films of stable layered nitrides

Controlled synthesis of metastable materials away from equilibrium is of interest in materials chemistry. Thin-film deposition methods with rapid condensation of vapour precursors can readily synthesize metastable phases but often struggle to yield the thermodynamic ground state. Growing thermodynamically stable structures using kinetically limited synthesis methods is important for practical applications in electronics and energy conversion. Here, in this study, we reveal a synthesis pathway to thermodynamically stable, ordered layered ternary nitride materials, and discuss why disordered metastable intermediate phases tend to form. We show that starting from elemental vapour precursors leads to a 3D long-range-disordered MgMoN 2 thin-film metastable intermediate structure, with a layered short-range order that has a low-energy transformation barrier to the layered 2D-like stable structure. This synthesis approach is extended to ScTaN 2 , MgWN 2 and MgTa 2 N 3 , and may lead to the synthesis of other layered nitride thin films with unique semiconducting and quantum properties.

36 MATERIALS SCIENCE↗

SiGe quantum wells with oscillating Ge concentrations for quantum dot qubits

Large-scale arrays of quantum-dot spin qubits in Si/SiGe quantum wells require large or tunable energy splittings of the valley states associated with degenerate conduction band minima. Existing proposals to deterministically enhance the valley splitting rely on sharp interfaces or modifications in the quantum well barriers that can be difficult to grow. Here, we propose and demonstrate a new heterostructure, the “Wiggle Well”, whose key feature is Ge concentration oscillations inside the quantum well. Experimentally, we show that placing Ge in the quantum well does not significantly impact our ability to form and manipulate single-electron quantum dots. We further observe large and widely tunable valley splittings, from 54 to 239 μ eV. Tight-binding calculations, and the tunability of the valley splitting, indicate that these results can mainly be attributed to random concentration fluctuations that are amplified by the presence of Ge alloy in the heterostructure, as opposed to a deterministic enhancement due to the concentration oscillations. Quantitative predictions for several other heterostructures point to the Wiggle Well as a robust method for reliably enhancing the valley splitting in future qubit devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel methodology to integrate outcomes regarding perioperative pain experience into a composite score: Prediction model development and validation

Abstract Background An integrated score that globally assesses perioperative pain experience and rationally weights each component has not yet been developed. Methods A development dataset specific to adult Chinese patients undergoing orthopaedic surgery was obtained from PAIN OUT (1985 qualified patients of 2244). A more recent validation dataset obeying the same conditions was obtained from the Chinese Anaesthesia Shared‐database Platform (1004 qualified patients of 1032). Outcomes were assessed using the International Pain Outcomes Questionnaire (IPO‐Q), which comprises key patient‐level outcomes of perioperative pain management, including pain experience and perceptions of care. Using principal component analysis and regression models, a composite score (CS) was inferred to integrate pain experience. The discrimination of the CS for dissatisfaction and desire for more pain treatment was compared with that of the worst pain score. Results A CS was developed from the 12 items of the IPO‐Q regarding pain experience. The weight for calculating the CS was worst pain 11, least pain 17, time spent in severe pain 11, interference with activity in bed 9, interference with breathing deeply or coughing 10, interference with sleep 9, anxiety 12, helplessness 12, nausea 0, drowsiness 2, itch 5 and dizziness 2. In external validation, the CS indicated superior discrimination to the worst pain in predicting dissatisfaction ( p < 0.001) and desire for more pain treatment ( p < 0.001). Conclusions This study introduced a methodology to integrate outcomes regarding perioperative pain experience into a CS, which was based on the weight of each item. Significance This novel methodology sheds additional light on the riveting issue of carefully integrating several measures into a composite endpoint, which may be useful for quality improvement purposes when addressing the impact of a change in clinical practice.

Jiang, Bailin↗

Analysis of implant loss risk factors after simultaneous guided bone regeneration: A retrospective study of 5404 dental implants

Abstract Purpose The purpose was to analyze the risk factors for implant loss after simultaneous guided bone regeneration (GBR). Materials and Methods Patients who underwent implant placement with simultaneous GBR between January 2011 and December 2018 were screened for this study. The cumulative survival rate (CSR) was calculated using the life table method. Log‐rank test and Kaplan–Meier survival estimates were used to identify potential risk factors for implant loss. The association between the investigated variables and implant loss was determined using hazard ratios (HRs) obtained from a multivariate Cox regression analysis. Results A total of 3973 patients with 5404 implants were included in this study. The CSRs of the implants at 1, 5, and 10 years were 99.6%, 98.9%, and 98.7%, respectively. Male patient (HR = 2.94, 95% CI: 1.41–6.14), periodontitis (HR = 4.26, 95% CI: 2.05–9.86), tissue‐level implants (HR = 3.02, 95% CI: 1.30–6.98), narrow implants (HR = 2.71, 95% CI: 1.12–6.57), and implant length ≤10 mm (HR = 2.91, 95% CI: 1.41–6.02) significantly increased the risk of implant loss ( p < 0.05). The risk of implant loss was significantly higher in the maxillary posterior region (HR = 2.26, 95% CI: 1.04–4.90) than in the maxillary anterior region ( p < 0.05). Compared to Straumann, Nobel (HR = 4.07, 95% CI: 1.75–9.44) and other implant systems (HR = 14.23, 95% CI: 4.32–46.85) showed a significantly higher risk of implant loss ( p < 0.05). Conclusion Male patient, periodontitis, maxillary posterior region, Nobel implant system, other implant systems, tissue‐level implants, narrow implants, and implant length ≤10 mm were considered risk factors for implant loss after simultaneous GBR.

Shen, Xiaoting↗