Search NASA⌕ Search

Engineering topics

Ferdowsi, Mehdi

Publications and source records attributed to Ferdowsi, Mehdi.

Enabling Extreme Fast Charging with Energy Storage Final Report

The objective of this project was to develop and demonstrate an extreme fast charging (XFC) station with three 350 kW charging ports that operate at a combined power exceeding 1 MW and mitigate the grid impact by employing smart charging algorithms, using an energy storage system, and connecting directly to a medium-voltage (15 kV-class three-phase) distribution feeder. This final report describes the team's achievements in all aspects of the technology development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive critic design-based reinforcement learning approach in controlling virtual inertia-based grid-connected inverters

In this report, an adaptive critic design (ACD) approach is proposed to control the phase and voltage of a grid-connected virtual synchronous generator (VSG). The penetration of fast responding inertia-less power converters significantly affect the stability of the power system, especially weak systems such as micro grids. The concept of virtual inertia addresses this concern by virtually emulating the behavior of a synchronous generator. However, the conventional VSG is designed based on two conditions: (i) fixed operating point and (ii) inductive grid connections. The performance of VSGs in low-voltage semi-resistive microgrids is far from optimal. To overcome the aforementioned concerns, a heuristic dynamic programing (HDP) approach is proposed to optimally control grid-connected VSGs. The neural-network-based inherence of the HDP enables the proposed technique to adapt to any impedance angle. The HDP controller includes two subnetworks: (i) the action network that controls the system optimally and (ii) the critic network, which evaluates the effectiveness of the action network. The simulation and experimental results are provided to evaluate the effectiveness of the proposed technique. As shown, the HDP-based approach illustrates a better performance in comparison with the conventional PI-based VSG in various operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Various Transformer Topologies for HF Isolation Applications

High-frequency (HF) transformers are an essential part of many power electronic devices. The performance and behavior of HF transformers can greatly affect the efficiency and performance of all systems, particularly, from a parasitic parameter point of view. In this article, HF transformers' parasitic parameters, such as leakage inductances and parasitic capacitances, are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements of different structures and winding arrangements. Also, the magnetic field, electric field, electric displacement field, and electric potential distribution within the transformers are simulated and analyzed. Four different HF transformers with E and U cores with different windings are designed and analyzed. Investigation outcomes help to classify structures according to the trade-off between leakage inductances and series parasitic capacitances. This information can later be used for the optimal selection and design of transformers as a function of their operating frequency for any power rating and voltage level. Moreover, 3-D FEM and experimental results validate the proposed methodology to be used for designing HF transformers in high-voltage/power applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Value Gradient Learning Approach in Power and Frequency Regulation of Grid-Connected Synchronverters

In this paper, a neural network adaptive critic design (ACD) method based on value gradient learning (VGL) is used to optimally control a grid-connected synchronverter. The main drawback of the traditional synchronverters is their infeasibility to face non-inductive grids. To be able to implement a synchronverter technique in any impedance angle, a neural network-based adaptive controller is used. The advantage of adaptive dynamic programing is its ability to adjust itself when it faces changes and uncertainties in the power system. The proposed VGL consists of two subnetworks: the critic network and the action network. The action network is trained during the operation, and the critic network can be pretrained offline or can be simultaneously trained with the action network. To compare the effectiveness of the traditional synchronverter to the VGL-based synchronverter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Heuristic Dynamic Programming Approach in Boost Converters

In this study, a heuristic dynamic programming controller is proposed to control a boost converter. Conventional controllers such as proportional-integral-derivative (PID) or proportional-integral (PI) are designed based on the linearized small-signal model near the operating point. Therefore, the performance of the controller during the start-up, the load change, or the input voltage variation is not optimal since the system model changes by varying the operating point. The heuristic dynamic programming controller optimally controls the boost converter by following the approximate dynamic programming. The advantage of the HDP is that the neural network-based characteristic of the proposed controller enables boost converters to easily cope with large disturbances. An HDP with a well-trained critic and action networks can perform as an optimal controller for the boost converter. To compare the effectiveness of the traditional PI-based and the HDP boost converter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual heuristic dynamic programing control of grid-connected synchronverters

A new approach to control a grid-connected synchronverter by using a dual heuristic dynamic programing (DHP) design is presented. The disadvantages of conventional synchronverter controller such as the challenges to cope with nonlinearity, uncertainties, and non-inductive grids are discussed. To deal with the aforementioned challenges a neural network–based adaptive critic design is introduced to optimize the associated cost function. The characteristic of the neural networks facilitates the performance under uncertainties and unknown parameters (e.g. different power angles). The proposed DHP design includes three neural networks: system NN, action NN, and critic NN. The simulation results compare the performance of the proposed DHP with a traditional PI-based design and with a neural network predictive controller. It is shown a well-trained DHP design performs in a trajectory, which is more optimal compared to the other two controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neural Network Predictive Controller for Grid-Connected Virtual Synchronous Generator

In this paper, a neural network predictive controller is proposed to regulate the active and the reactive power delivered to the grid generated by a three-phase virtual inertia-based inverter. The concept of the conventional virtual synchronous generator (VSG) is discussed, and it is shown that when the inverter is connected to non-inductive grids, the conventional PI-based VSGs are unable to perform acceptable tracking. The concept of the neural network predictive controller is also discussed to replace the traditional VSGs. This replacement enables inverters to perform in both inductive and non-inductive grids. The simulation results confirm that a well-trained neural network predictive controller illustrates can adapt to any grid impedance angle, compared to the traditional PI-based virtual inertia controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heuristic Dynamic Programming for Adaptive Virtual Synchronous Generators

In this paper a neural network heuristic dynamic programing (HDP) is used for optimal control of the virtual inertia-based control of grid connected three-phase inverters. It is shown that the conventional virtual inertia controllers are not suited for non-inductive grids. A neural network-based controller is proposed to adapt to any impedance angle. Applying an adaptive dynamic programming controller instead of a supervised controlled method enables the system to adjust itself to different conditions. The proposed HDP consists of two subnetworks: critic network and action network. These networks can be trained during the same training cycle to decrease the training time. The simulation results confirm that the proposed neural network HDP controller performs better than the traditional direct-fed voltage and/or reactive power controllers in virtual inertia control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ripple canceling in power conversions circuits

A power circuit substantially canceling ripples at the source. The power circuit includes a switching circuit configured to control a power flow between an input and an output, a main storage element electrically connected in series with the switching circuit, and a resonant tank electrically coupled to the switching circuit and configured to compensate for switching ripples in the main storage element. Aspects of the invention can be applied to a converter circuit or to an inverter circuit.

Shamsi, Pourya↗

Analysis and design of bipolar Dickson DC-DC converter

This paper presents a novel converter based on the Dickson voltage multiplier for high voltage applications. This converter will have two Dickson chains connected differently to improve the original Dickson voltage multiplier. The main advantage of this converter is that the stresses on the capacitor will be reduced by half, and the output voltage ripples are reduced. The required energy storage of the capacitor is 30% of the original Dickson voltage switched capacitor converter. The analysis and design of this converter are presented and verified by simulation. A 20W prototype was implemented to validate the analysis and simulation. Furthermore, the results show that the proposed converter is an improved version of the original Dickson and modified Dickson converters and it has higher efficiency up to 94%.

42 ENGINEERING↗