Search NASA⌕ Search

Engineering topics

Fernandez, Nicholas

Publications and source records attributed to Fernandez, Nicholas.

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing the Performance and Dynamic Control of Energy-Efficient Cellular Shades in the PNNL Lab Homes

This report describes the experimental design and results of testing the energy performance of Hunter Douglas double-cell cellular shades under various control schemes in the Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments are presented, where testing is designed to assess the heating, ventilation, and air conditioning (HVAC) savings resulting from the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Success of Commercial Building Re-tuning in Federal Buildings: Results and Case Studies

Re-tuning is a form of scaled-down retrocomissioning for commercial buildings that targets low- and no-cost control changes to building automation systems (BASs) to achieve immediate energy savings. A retrospective analysis of re-tuning for a set of 26 Federal office buildings and courthouses is presented, detailing the re-tuning process that was employed, the types of re-tuning measures that were commonly implemented, the most impactful of those measures, and an analysis of the energy and cost savings achieved as a result of the process. The portfolio of buildings that participated in these re-tuning efforts was benchmarked as having, on average, very efficient baselines. However, these buildings achieved, on average, 12.1% annual energy savings as a result of the re-tuning efforts, with an associated cost savings of $1.62/year per square meter of floor space ($0.151/year per square foot). Several key factors that are observed to promote successful re-tuning outcomes are discussed as well.

Fernandez, Nicholas↗

Valuation of Transactive Systems

This is a final report from a project funded by the U.S. Department of Energy to formulate and test a methodology for valuation of systems where transaction-based mechanisms coordinate the exchange of value between the system’s actors. Today, the principal commodity being exchanged is electrical energy, and such mechanisms are called transactive energy systems. The authors strove to lay a foundation for meaningful valuations of transactive systems in general, and transactive energy systems as a special case. The word valuation is used in many different ways. This report proposes a valuation methodology that is inclusive of many types of valuations. Many will be familiar with cost-benefit valuations, in which both costs and benefits are assessed to determine whether the assets are worth their cost. Another set of valuation methods attempt to optimize an outcome using available resources, as is the case with integrated resource planning. In the end, this report’s methodology was most influenced by and most resembles the integrated-resource-planning approach. Regardless, we wish to enforce the premise that all valuations are comparative and should clearly specify a baseline scenario. A long, annotated list of prior valuation studies and valuation methodologies that influenced this report has been appended to this report. Much research is being conducted today concerning transactive systems, but only a handful of transactive system mechanisms have been formulated and field tested. They are found to be quite diverse, and the documentation of the various mechanisms is uneven in breadth and quality. It is therefore not adequate to simply assert that a valuation scenario includes a transactive system; certain characteristics and qualities of the chosen transactive system mechanism must be defined and stated. The report lists and discusses most of the known transactive system mechanisms. It offers a set of questions that may be used to help specify important characteristics of the transactive system mechanisms, which should be conveyed along with other valuation results. A valuation methodology is proposed. Some abstraction is necessarily retained so that the methodology may be applied for the many purposes of today’s valuations and across grid, building, societal, and other domains. The report’s methodology advocates separation of operational timescales from long-term growth timescales. Operational models are defined as the models that inform impacts within the relatively short, often yearlong, operational time periods. Growth models define how the scenarios evolve from one operational period to the next (e.g., from year to year). We believe the recommended methodology is a critical step toward collaborative community platforms, where analysts and decision makers alike could contribute and borrow content within their expertise. The report then asks, what is unique about valuations when systems become coordinated by transactive systems? In answer, accurate valuations of transactive systems require careful adherence to the dynamic interaction between a system’s responsive elements and the system’s operational objectives. In every transactive system mechanism, elements respond to incentives that become revealed to them, and certain operational objectives become explicitly incentivized by the transactive system mechanism. The transactive system mechanisms define the important coupling between the responsive elements and the system’s objectives.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Savings Potential of Radiative Cooling Technologies

Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), conducted a study to estimate, through simulation, the potential cooling energy savings that could be achieved through novel approaches to capturing free radiative cooling in buildings, particularly photonic ‘selective emittance’ materials. This report documents the results of that study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transaction-Based Building Controls Framework, Volume 1: Reference Guide

This document proposes a framework concept to achieve the objectives of raising buildings’ efficiency and energy savings potential benefitting building owners and operators. We call it a transaction-based framework, wherein mutually-beneficial and cost-effective market-based transactions can be enabled between multiple players across different domains. Transaction-based building controls are one part of the transactional energy framework. While these controls realize benefits by enabling automatic, market-based intra-building efficiency optimizations, the transactional energy framework provides similar benefits using the same market -based structure, yet on a larger scale and beyond just buildings, to the society at large.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗