Search NASA⌕ Search

Engineering topics

Fernex, Frédéric

Publications and source records attributed to Fernex, Frédéric.

Resolved Resonance Evaluation for Neutron Interactions with 103 Rh up to 8 keV

A neutron cross-section evaluation for the n + 103 Rh reaction in the resolved resonance region was carried out in the energy range 10−5 eV to 8 keV encompassing thermal energy at 0.0253 eV. The scope of this work is to generate resonance parameters and resonance parameter covariances based on the Reich-Moore reduced R-matrix formalism using the code SAMMY. Some features of the new evaluation are the inclusion of high-resolution capture data in the SAMMY evaluation process and the extension of the resolved resonance range from 4 to 8 keV. Furthermore, the evaluation employs more accurate resonance parameter representation by exploring the use of the LRF = 7 ENDF feature and also the use of the LCOMP = 2 compact format for resonance parameter covariance representation. Included in the SAMMY evaluation are transmission data, capture cross-section data, and neutron scattering length information. Thermal cross-section values listed in the literature, as well as capture resonance integrals, were also incorporated into the evaluation process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation [Abstract]

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) selected as application models: IEU-MET- FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP- THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET- FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗