Search NASA⌕ Search

Engineering topics

Ferrara, A.

Publications and source records attributed to Ferrara, A..

The behavior of fragments of comet Shoemaker-Levy 9 in the atmosphere of Jupiter

Studies of the entry of fragments of comet Shoemaker-Levy 9 into the atmosphere of Jupiter give conflicting predictions as to whether or not most of the energy is deposited above the clouds. Using analytical models, we find that for a typical fragment radius of 1.5 km, both deceleration and mass loss (ablation) are negligible above the 1 bar level, so most of the energy will be deposited below the clouds, where radiation is blocked from escaping. The bulk of the energy produced by entering fragments will be observable only if the energy deposited below the clouds is transported above the clouds by means other than radiation. We provide new calculations of the flattening of fragments by ram pressure, of radiation-driven evaporative ablation and of ablation of droplets formed by Kelvin-Helmholtz instability.

Field, G. B.↗

Radio emission from spinning grains

We present a study of the radio emission from rotating, charged dust grains immersed in the ionized gas constituting the thick, H alpha-emitting disk of many spiral galaxies.

Ferrara, A.↗

The impact of supernova fragments on the evolution of multisupernova remnants

Analytical approximations and 2D hydrodynamical simulations are used to examine the interaction of supernova fragments with the internal structure of large multisupernova remnants (MSRs). The fragments are thermalized by reverse shocks generated in the interaction with the MSR interior, which is assumed to be hot and rarefied. The evolution is divided into two stages: before and after reaching a reference distance, R(E), from the explosion site. As the density of the expanding fragment drops, the reverse shock accelerates, and, when the distance R(E) is reached, it begins to effectively erode the fragment. At some selected evolutionary times, the X-ray emission from the shocked fragment is also calculated. The direct bombardment of the MRS shell by the shocked fragment has a series of important consequences: it excites, punctures, and deforms the expanding shell.

Franco, J.↗

Identification of two hard X-ray emitting Be stars using the HEAO 1 scanning modulation collimator

Using precise positions from the HEAO 1 Scanning Modulation Collimator experiment, two hard X-ray sources, 4U 0728 - 25 = 3A 0726 - 260 and 4U 2206 + 54 = 3A 2206 + 543, are identified with early-type stars. In both cases broad (10 A FWHM) H-alpha emission is detected. The UBV colors suggest that the optical counterparts are main-sequence B0-B2 stars at 2-6 kpc, implying a mean X-ray luminosity of order 10 to the 35th ergs/sq cm s (2-10 keV). The X-ray emission in both cases is highly variable, and it is suggested that they belong to the class of X-ray emitting Be stars, containing a neutron star in a widely separated binary system.

Steiner, J. E.↗

Fabrication and evaluation of RX-6450 /NCNS-13P/ composites

The chemistry, processing, and laminate properties of NCNS-13P resin are described. The effect on graphite fiber laminates of temperature, oxidative aging, water absorption, and humidity-temperature aging were determined. Glass laminates were evaluated for the fire resistance and smoke and toxic gas evolution under flaming conditions.

Kray, R. J.↗

Molten salt thermal energy storage for utility peaking loads

This paper considers the use of thermal energy storage (TES) in molten salts to increase the capacity of power plants. Five existing fossil and nuclear electric utility plants were selected as representative of current technology. A review of system load diagrams indicated that TES to meet loads over 95% of peak was a reasonable goal. Alternate TES heat exchanger locations were evaluated, showing that the stored energy should be used either for feedwater heating or to generate steam for an auxiliary power cycle. Specific salts for each concept are recommended. Design layouts were prepared for one plant, and it was shown that a TES tube/shell heat exchanger system could provide about 7% peaking capability at lower cost than adding steam generation capacity. Promising alternate heat exchanger concepts were also identified.

Ferrara, A.↗