Search NASA⌕ Search

Engineering topics

Fierro, Gabe

Publications and source records attributed to Fierro, Gabe.

25 records · Page 2

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent self-descriptive notions of the “things”. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, automatically identifying and diagnosing faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework to verify compliance of products with semantic interoperability specifications. This approach is designed to accelerate the timeline for adoption of semantic interoperability specifications. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies and use cases as a necessary step in achieving an energy efficient smart grid future.

30 DIRECT ENERGY CONVERSION↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

Mortar: An Open Testbed for Portable Building Analytics

Access to large amounts of real-world data has long been a barrier to the development and evaluation of analytics applications for the built environment. Open datasets exist, but they are limited in their span (how much data is available) and context (what kind of data is available and how it is described). Evaluation of such analytics is also limited by how the analytics themselves are implemented, often using hard-coded names of building components, points and locations, or unique input data formats. To advance the methodology for how such analytics are implemented and evaluated, we present Mortar: an open testbed for portable building analytics, currently spanning 90 buildings and containing over 9.1 billion data points. All buildings in the testbed are described using Brick, a recently developed metadata schema, providing rich functional descriptions of building assets and subsystems. We also propose a simple architecture for writing portable analytics applications that are robust to the diversity of buildings and can configure themselves based on context. We demonstrate the utility of Mortar by implementing 11 applications from the literature.

47 OTHER INSTRUMENTATION↗

WAVE: A Decentralized Authorization Framework with Transitive Delegation

Most deployed authorization systems rely on a central trusted service whose compromise can lead to the breach of millions of user accounts and permissions. We present WAVE, an authorization framework offering decentralized trust: no central services can modify or see permissions and any participant can delegate a portion of their permissions autonomously. To achieve this goal, WAVE adopts an expressive authorization model, enforces it cryptographically, protects permissions via a novel encryption protocol while enabling discovery of permissions, and stores them in an un-trusted scalable storage solution. WAVE provides competitive performance to traditional authorization systems relying on central trust. Lastly, it is an open-source artifact and has been used for two years for controlling 800 IoT devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant comfort and behavior: High-resolution data from a 6-month field study of personal comfort systems with 37 real office workers

Personal Comfort Systems (PCS) provide individual occupants local heating and cooling to meet their comfort needs without affecting others in the same space. It saves energy by relaxing ambient temperature requirements for the HVAC system. Aside from these benefits, PCS offers a wealth of data that can describe how individuals interact with heating/cooling devices in their own environment. Recently developed Internet-connected PCS chairs have unlocked this opportunity by generating continuous streams of heating and cooling usage data, along with occupancy status and environmental measurements via embedded sensors. The data allow individuals' comfort and behavior to be learned, and can inform centralized systems to provide ‘just the right’ amount of conditioning to meet occupant needs. In summer 2016, we carried out a study with PCS chairs involving 37 occupants in an office building in California. During the study period, we collected >5 million chair usage data-points and 4500 occupant survey responses, as well as continuous measurements of environmental and HVAC system conditions. The data analysis shows that (1) local temperatures experienced by individual occupants vary quite widely across different parts of the building, even within the same thermal zone; (2) occupants often have different thermal preferences even under the same thermal conditions; (3) PCS control behavior can dynamically describe individuals' thermal preferences; (4) PCS chairs produce much higher comfort satisfaction (96%) than typically achieved in buildings. We conclude that PCS not only provide personalized comfort solutions but also offer individualized feedback that can improve comfort analytics and control decisions in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mortar: An open testbed for portable building analytics

Access to large amounts of real-world data has long been a barrier to the development and evaluation of analytics applications for the built environment. Open data sets exist, but they are limited in their span (how much data is available) and context (what kind of data is available and how it is described). Evaluation of such analytics is also limited by how the analytics themselves are implemented, often using hard-coded names of building components, points and locations, or unique input data formats. To advance the methodology for how such analytics are implemented and evaluated, we present Mortar: an open testbed for portable building analytics, currently spanning 90 buildings and containing over 9.1 billion data points. All buildings in the testbed are described using Brick, a recently developed metadata schema, providing rich functional descriptions of building assets and subsystems. We also propose a simple architecture for writing portable analytics applications that are robust to the diversity of buildings and can configure themselves based on context. We demonstrate the utility of Mortar by implementing 11 applications from the literature.

data set↗