Search NASA⌕ Search

Engineering topics

Figueroa-Feliciano, E

Publications and source records attributed to Figueroa-Feliciano, E.

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment

The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $\alpha$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $\alpha$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.

100Mo↗