Search NASA⌕ Search

Engineering topics

Finden, L. E.

Publications and source records attributed to Finden, L. E..

25-LBF GO2/GH2 space station thruster

Multiple 25-lbf oxygen/gaseous hydrogen thruster assemblies for the Space Station propulsion application were designed and fabricated by Rocketdyne and endurance tested at the NASA/Marshall Space Flight Center. The thrusters incorporate a regeneratively cooled thrust chamber with a nozzle area ratio of 30, a 12-element coaxial injector, an ignition system, and close-coupled propellant valves. The various thruster configurations comprised of mating different injectors and thrust chambers. Over 2 million lbf-sec of impulse was demonstrated at mixture ratios from 3 to 8.4 at vacuum conditions. A thruster was subjected to over 10,000 pulses during which minimum impulse bits of less than 0.5 lb/sec were repeatedly and reliably demonstrated. A total operating time of 25.6 hr was accumulated on the thruster assemblies with one 6.1-hr. continuous firing duration. The thrusters operated between a thrust range of 11.2 and 36.6 lbf. The test results indicate that all major technology issues for long-life gaseous oxygen/gaseous hydrogen thrusters for the Space Station application have been resolved.

Finden, L. E.↗

Space station resistojet system requirements and interface definition study

A conceptual design study of the resistojet orbital replacement unit (ORU) was conducted. The ORU consists of four 500-W multipropellant resistojets, fluid components downstream of the waste fluid storage subsystem, a power controller, structure, and micrometeorite shielding. The fluid components include latch valves, a water vaporizer, two pressure regulators or flow control valves, filters, check valves, fluid tubing, and interface couplings. Separate fluid components are provided for oxidizing fluids, reducing fluids and water. Different flow and power control methods were studied. The most promising methods consist of a constant pressure/on-off power control and a constant power/variable pressure control. The closed-loop power control incorporates a feedback signal which is proportional to resistojet heater temperature.

Finden, L. E.↗