Search NASA⌕ Search

Engineering topics

Fink, C. W.

Publications and source records attributed to Fink, C. W..

Demonstration of the HeRALD superfluid helium detector concept

The SPICE/HeRALD collaboration is performing research and development to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid 4 He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and 4 He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical “quantum evaporation” signal from 4 He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype “HeRALD v0.1” detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. Here, a key result of this work is the measurement of the quantum evaporation channel’s gain of 0.15±0.01, which will enable 4 He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5⁢σ, which would be sensitive to dark matter masses down to 220 MeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of the Nuclear-Recoil Ionization Yield in Silicon at 100 eV

We measured the nuclear-recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. In conclusion, these results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

A backing detector for order-keV neutrons

In this work, we have designed and tested a large-area (0.15 m 2 ) neutron detector based on neutron capture on 6Li. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy (<100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$\textit{v}$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of ~25% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of ~ 17 μs. The prototype was characterized using a 252 Cf neutron source and agreement with the simulation was observed within a few percent level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, Y 88 Be 9 and Sb 124 Be 9 , have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. In this study, we evaluate the yield for nuclear recoil energies between 1 and 7 keV at a temperature of ~ 50 mK . We use a geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Performance of a large area photon detector for rare event search applications

We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm 2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature T c = 41.5 mK to measure a thermal phonons released from interactions with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗