Search NASA⌕ Search

Engineering topics

Fisher, S E

Publications and source records attributed to Fisher, S E.

At least 19 records

Strontium Iodide Instrument Development for Gamma Spectroscopy and Radioisotope Identification

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), has progressed significantly in recent years. SrI2(Eu) has excellent material properties for gamma ray spectroscopy: high light yield (>80,000 ph/MeV), excellent light yield proportionality, and high effective atomic number (Z=49) for high photoelectric cross-section. High quality 1.5 and 2 diameter boules are now available due to rapid advances in SrI2(Eu) crystal growth. In these large SrI2(Eu) crystals, optical self-absorption by Eu2+ degrades the energy resolution as measured by analog electronics, but we mitigate this effect through on-the-fly correction of the scintillation pulses by digital readout electronics. Using this digital correction technique we have demonstrated energy resolution of 2.9% FWHM at 662 keV for a 4 in3 SrI2(Eu) crystal, over 2.6 inches long. Based on this digital readout technology, we have developed a detector prototype with greatly improved radioisotope identification capability compared to Sodium Iodide, NaI(Tl). The higher resolution of SrI2(Eu) yields a factor of 2 to 5 improvement in radioisotope identification (RIID) error rate compared to NaI(Tl).

energy resolution↗

Characteristics of Un doped and Europium-dopedSrI2 Scintillator Detectors

High energy resolution gamma-ray detectors that can be formed into relatively large sizes while operating at room temperature offer many advantages for national security applications. We are working toward that goal through the development of SrI{sub 2}(Eu) scintillator detectors, which routinely provide <;3.0% energy resolution at 662 keV with volumes >;10 cm{sup 3}. In this study, we have tested pure, undoped SrI{sub 2} to gain a better understanding of the scintillation properties and spectroscopic performance achievable without activation. An undoped crystal grown from 99.999% pure SrI{sub 2} pellets was tested for its spectroscopic performance, its light yield, and uniformity of scintillation light collection as a function of gamma-ray interaction position relative to the crystal growth direction. Undoped SrI{sub 2} was found to provide energy resolution of 5.3% at 662 keV, and the light collection nonuniformity varied by only 0.72% over the length of the crystal. Measurements of both a 3% Eu-doped and the undoped SrI{sub 2} crystal were carried out in the SLYNCI facility and indicate differences in their light yield non-proportionality. The surprisingly good scintillation properties of the pure SrI{sub 2} crystal suggests that with high-purity feedstock, further reduction of the Eu concentration can be made to grow larger crystals while not adversely impacting the spectroscopic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Europium-Doped Strontium Iodide, Transparent Ceramics and Bismuth-loaded Polymer Scintillators

Recently discovered scintillators for gamma ray spectroscopy, single crystal SrI{sub 2}(Eu), GYGAG(Ce) transparent ceramic and Bismuth-loaded plastics, offer resolution and fabrication advantages compared to commercial scintillators, such as NaI(Tl) and standard PVT plastic. Energy resolution at 662 keV of 2.7% is obtained with SrI{sub 2}(Eu), while 4.5% is obtained with GYGAG(Ce). A new transparent ceramic scintillator for radiographic imaging systems, GLO(Eu) offers high light yield of 70,000 Photons/MeV, high stopping, and low radiation damage. Implementation of single crystal SrI{sub 2}(Eu), Gd-based transparent ceramics, and Bi-loaded plastic scintillators can advance the state-of-the art in ionizing radiation detection systems.

36 MATERIALS SCIENCE↗

Electrodeposition of Uranium and Plutonium on Thin Carbon and Titanium Substrates

Preparation of Pu and U targets on thin natural C (100 {micro}g/cm{sup 2}) and ti (2 and 3 {micro}m) substrates is described. The Actinide material of interest was first purified using ion exchange chromatography to remove any matrix contaminants or decay products present in the parent stock solution. The actinide solution was prepared in 0.05 M HNO{sub 3} with a final aliquot volume not exceeding 100 {micro}L for the deposition procedure. The electroplating cells were developed in-house and were primarily made of Teflon. The source material deposited ranged from 125 to 400 {micro}g/cm{sup 2}. It was determined that multiple layers of U and Pu were required to produce thicker targets on Ti. Plating efficiency was greatly affected by the cell volume, solution aliquot size, pre-treatment of the foils, solution mixing during palting, and the fit of the electrode contact with the target substrate. The final procedure used for deposition is described in detail.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Packaging SrI2(Eu) Scintillator Crystals

Recent renewed emphasis placed on gamma-ray detectors for national security purposes has motivated 13 researchers to identify and develop new scintillator materials capable of high energy resolution and 14 growable to large sizes. We have discovered that SrI2(Eu) has many desirable properties for gamma-ray 15 detection and spectroscopy, including high light yield of ~90,000 photons/MeV and excellent light yield 16 proportionality. Furthermore, we have demonstrated growth of crack-free 2 diameter boules. We 17 have measured <2.7% FWHM at 662 keV with small detectors (<1 cm3) in direct contact with a 18 photomultiplier tube, and ~3% resolution at 662 keV is obtained for 1 in3 crystals. Due to the 19 hygroscopic nature of SrI2(Eu), proper packaging is required for field use. This work describes a 20 systematic study performed to determine the key factors in the packaging process to optimize 21 performance. These factors include proper polishing of the surface, the geometry of the crystal, 22 reflector materials and windows. A technique based on use of a collimated Cs-137 source was developed 23 to examine light collection uniformity. Employing this technique, we found that when the crystal is 24 packaged properly, the variance in the pulse height at 662 keV from events near the bottom of the 25 crystal compared to those near the top of the crystal could be reduced to <1%. This paper describes the 26 design and engineering of our detector package in order to improve energy resolution of 1 in3-scale 27 SrI2(Eu) crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Gamma Spectroscopy with SrI2(Eu), GYGAG(Ce) and Bi-loaded Plastic Scintillators

We are developing new scintillator materials that offer potential for high resolution gamma ray spectroscopy at low cost. Single crystal SrI2(Eu) offers ~3% resolution at 662 keV, in sizes of ~1 in3. We have developed ceramics processing technology allowing us to achieve cubic inch scale transparent ceramic scintillators offering gamma spectroscopy performance superior to NaI(Tl). We fabricated a bismuth-loaded plastic scintillator that demonstrates energy resolution of ~8% at 662 keV in small sizes.

Cherepy, Nerine↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI{sub 2}(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI{sub 2} crystals with volumes >10 cm{sup 3}. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI{sub 2}(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development of SrI{sub 2}(Eu) detectors for national security purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OVERVIEW OF MONO-ENERGETIC GAMMA-RAY SOURCES & APPLICATIONS

Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable Mono-Energetic Gamma-ray (MEGa-ray) source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC NAL will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. This MEGa-ray source will be used to excite nuclear resonance fluorescence in various isotopes. Applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented, along with important applications, including nuclear resonance fluorescence. In conclusion, we have optimized the design of a high brightness Compton scattering gamma-ray source, specifically designed for NRF applications. Two different parameters sets have been considered: one where the number of photons scattered in a single shot reaches approximately 7.5 x 10{sup 8}, with a focal spot size around 8 {micro}m; in the second set, the spectral brightness is optimized by using a 20 {micro}m spot size, with 0.2% relative bandwidth.

42 ENGINEERING↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI2(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI2 crystals with volumes >10 cm3. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI2(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development