Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of manganese oxide and activated carbon fibers for removing a particle, volatile organic compound or ozone from a gas

The present invention provides for a device for reducing a volatile organic compound (VOC) content of a gas comprising a manganese oxide (MnO x ) catalyst. The manganese oxide (MnO x ) catalyst is capable of catalyzing formaldehyde at room temperature, with complete conversion, to CO 2 and water vapor. The manganese oxide (MnO x ) catalyst itself is not consumed by the reaction of formaldehyde into CO 2 and water vapor. The present invention also provides for a device for reducing or removing a particle, a VOC and/or ozone from a gas comprising an activated carbon filter (ACF) on a media that is capable of being periodically regenerated.

Sidheswaran, Meera A.↗

Use of manganese oxide and activated carbon fibers for removing a particle, volatile organic compound or ozone from a gas

The present invention provides for a device for reducing a volatile organic compound (VOC) content of a gas comprising a manganese oxide (MnO.sub.x) catalyst. The manganese oxide (MnO.sub.x) catalyst is capable of catalyzing formaldehyde at room temperature, with complete conversion, to CO.sub.2 and water vapor. The manganese oxide (MnO.sub.x) catalyst itself is not consumed by the reaction of formaldehyde into CO.sub.2 and water vapor. The present invention also provides for a device for reducing or removing a particle, a VOC and/or ozone from a gas comprising an activated carbon filter (ACF) on a media that is capable of being periodically regenerated.

36 MATERIALS SCIENCE↗

A longitudinal study of ventilation rates in California office buildings and self-reported occupant outcomes including respiratory illness absence

Limited evidence has associated lower ventilation rates (VRs) in offices with higher illness-related absence rates. We studied spaces in office buildings, selected without knowledge of their VRs, in three California climate zones. In each study space, real-time logging sensors measured carbon dioxide and thermal parameters for one year. Web-based surveys every three months collected data on occupants’ health outcomes. Using multivariate models, relationships were assessed between CO 2 concentrations, or VRs estimated from CO 2 , and adverse occupant outcomes including respiratory infections and illness absences. For all outcomes, positive associations were hypothesized with higher CO 2 levels (and negative associations with higher VRs). Low survey response limited sample size and study power. In the 16 study spaces, CO 2 concentrations were uniformly low over the year, and most estimated VRs ranged from twice to nine times the California office minimum VR standard (7 L/s or 15 cfm per person). Primary CO 2 and VR metrics had no statistically significant relationships with occupant outcomes. Within the observed range of uniformly low CO 2 and high VRs (mostly 16–42 L/s per person), little variation in contaminant concentrations would be expected, which would explain lack of relationships with occupant outcomes. These high VRs resulted partly from frequently used energy-saving “economizer” cycles in moderate California climates, but VRs at other times also substantially exceeded required VRs. These findings suggest, consistent with theory, that within a higher VR range, increased VRs do not reduce respiratory illness. Further studies are needed to better characterize such relationships.

60 APPLIED LIFE SCIENCES↗

Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s -1 (12.6 km h -1 ) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

42 ENGINEERING↗

Energy and IAQ Implications of Alternative Minimum Ventilation Rates in California Retail and School Buildings

For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may provide initial evidence for an upper bound of the range of VRs within which increased VRs provide benefits in reducing illness absence.

54 ENVIRONMENTAL SCIENCES↗

Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each specific outcome threshold are estimated; and the highest of these MVRs, which would then meet all outcome thresholds, is selected as the target MVR. In a second step, implemented only if the target MVR from step 1 is judged impractically high, costs and benefits are estimated and this information is used in a risk management process. Four human outcomes with substantial quantitative evidence of relationships to VRs are identified for initial consideration in setting MVR standards. These are: building-related symptoms (sometimes called sick building syndrome symptoms), poor perceived indoor air quality, and diminished work performance, all with data relating them directly to VRs; and cancer and non-cancer chronic outcomes, related indirectly to VRs through specific VR-influenced indoor contaminants. In an application of step 1 for offices using a set of example outcome thresholds, a target MVR of 9 L/s (19 cfm) per person was needed. Because this target MVR was close to MVRs in current standards, use of a cost/benefit process seemed unnecessary. Selection of more stringent thresholds for one or more human outcomes, however, could raise the target MVR to 14 L/s (30 cfm) per person or higher, triggering the step 2 risk management process. Consideration of outdoor air pollutant effects would add further complexity to the framework. For balancing the objective and subjective factors involved in setting MVRs in a cost-benefit process, it is suggested that a diverse group of stakeholders make the determination after assembling as much quantitative data as possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand controlled ventilation and classroom ventilation

This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗