Collector temperature effects on the performance of advanced thermionic converters and nuclear electric propulsion systems

The specific weight of a thermionic nuclear electric propulsion (NEP) system depends on the collector temperature because of changes in power density, efficiency and the temperature of heat rejection. Increasing the collector temperature above the value for maximum converter performance decreases both the efficiency and the power density of the converters, but the specific weight of the total system is decreased because of the reduction in radiator weight due to the increased heat rejection temperature. The effect of collector temperature on the performance of thermionic converters was investigated. The behavior of conventional ignited mode converters as well as advanced converters with lower collector work functions; the specific mass of an 'uninsulated' NEP system design was then evaluated as a function of collector temperature. The uninsulated design uses the electrical resistance of the heat pipes between the converters and the reactor to provide electrical insolation, eliminating the need for ceramic insulators at emitter temperature and providing other design advantages. The results indicate that an optimum collector temperature, which minimizes system weight, exists at a temperature above the optimum temperature for converter performance.

Dick, R. S.↗

Power Coupling Alternatives for the NEP Thermionic Power System

Three output power coupling methods which can eliminate the high temperature insulator from the Nuclear Electric Propulsion (NEP) power system are described and estimates of their effects on the NEP system masses and cooling requirements are presented. Nominal 400 kWe power systems using push-pull and flux reset inductive output coupling are shown to have specific masses of 22.2 kg/kWe and 18.8 kg/kWe, respectively. Series connected heat pipe systems, which use the heat pipe-to-heat pipe resistance to isolate converters on adjacent heat pipes, are shown to have specific masses 0.5 to 1.4 kg/kWe lower than the NEP baseline system. Increasing the number and temperature of the heat pipes in the system without changing the electric output reduces the calculated system specific mass only slightly, whereas increasing the output power significantly reduces the specific mass. Estimates of cooling requirements indicate that 11-45 sq m of power conditioning radiator are needed. A possible location for the power conditioning radiator may be in the present location of the kapton sputter shield.

Manda, M. L.↗

Thermionic topping for central station power plants

This paper describes recent results of the second phase of system analyses on the thermionic topping cycle. A comparison is made among various thermionic heat-exchanger (THX) geometries. Two methods of transferring electric power are considered. In the first, power is provided at relatively high voltages by coupling it out inductively via transformers built into the THX modules. In the second method, converter cells are series-connected within a THX module and external power conditioning is used. The results show that the use of a thermionic topping cycle can result in significant improvements in overall system efficiency.

Britt, E. J.↗

The plasmatron as an advanced performance thermionic converter

A study concerned with the improvement of thermionic converter performance has shown that the plasma arc drop of the conventional arc (ignited) mode converter can be suppressed by use of an auxiliary ion source as in a plasmatron converter. However, this improved performance is now limited to low current densities and narrow interelectrode spacings because of voltage losses due to plasma resistance. An examination of plasmatron performance characteristics for both argon and cesium plasma has shown that the argon plasmatron is superior.

Hansen, L. K.↗

Practical aspects of plasma processes in thermionic energy converters

Over a decade of cesium vapor thermionic converter research has yielded sufficient understanding of the basic plasma processes to permit application of this understanding to improvement of converter performance. A performance index is defined which relates such converter improvements directly to increases in system performance. A prime practical objective of current research is to reduce or eliminate the arc potential drop presently required to sustain the plasma in the ignited cesium diode. This will substantially increase the energy conversion efficiency, and will permit operation at substantially lower emitter temperatures without requiring lower collector (heat rejection) temperature. Present work is concentrating on evaluating and reducing to practice the several methods employing auxiliary ion sources to eliminate the arc drop which were demonstrated over a decade ago: i.e., various ignited and unignited triode concepts, and the pulse-enhanced diode and triode. These methods are reviewed in light of present understanding and recent experimental data.

Rasor, N. S.↗

Thermionic topping of electric power plants

The most likely use of thermionic conversion is in the form of a topping cycle combined with a steam-turbogenerator plant. A specific reference system is chosen in which the thermionic topping cycle occurs in thermionic heat exchangers referred to as large, modular thermionic units to which heat is transferred from a separate heat source and which reject their heat to a conventional steam turboelectric system. Results of analysis show that the performance and cost criteria for practical thermionic topping of large electric power plants are well within the reach of demonstrated and foreseeable converter capabilities. Thermionic topping has many significant advantages over unconventional cycles proposed for topping applications, including level of demonstrated and projected performance and lifetime, development time, and design simplicity.

Britt, E. J.↗