Search NASA⌕ Search

Engineering topics

Fletcher, D. G.

Publications and source records attributed to Fletcher, D. G..

Stagnation Point Heat Transfer with Gas Injection Cooling

The present paper deals with an experimental study of the stagnation-point heat transfer to a cooled copper surface with gas injection under subsonic conditions. Test were made with a probe that combined a steady-state water-cooled calorimeter that allows the capability to study convective blockage and to perform heat transfer measurements in presence of gas injection in the stagnation region. The copper probe was pierced by 52 holes, representing 2.4% of the total probe surface. The 1.2 MW high enthalpy plasma wind tunnel was operated at anode powers between 130 and 230 kW and a static pressures from 35 hPa up to 200 hPa. Air, carbon dioxide and argon were injected in the mass flow range 0-0.4 g/s in the boundary layer developed around the 50 mm diameter probe. The measured stagnation-point heat transfer rates are reported and discussed.

Vancrayenest, B.↗

Analysis of Emission Spectra from Arc-jet Shock Layer Flows

This paper reports computational comparisons with experimental studies of a nonequilibrium blunt body shock layer in a high enthalpy arc-jet wind tunnel at NASA Ames Research Center. The primary objective of this work is to investigate the existence of a thermochemical equilibrium region in the shock layer. The existence of such an equilibrium region is of interest for following reasons: (1) to understand the equilibration process behind the shock in an arc-jet flow environment; (2) to interpret measured surface heat transfer data for purpose of determining surface catalytic efficiency, and (3) to determine the total enthalpy from the spectroscopic measurements. The paper will present an analysis of the experimental data obtained in the arc-jet wind tunnel. Experimental data includes measurements of emission spectra of radiation emanating from a shock layer formed in front of a 6-inch flat-faced cylinder. The measurements, obtained using a two dimensional CCD camera mounted on a spectrograph, provide spatially resolved spectra along the stagnation streamline of the model. Computational analysis includes simulation of nonequilibrium flow in the arc-jet facility (flow in the conical nozzle and shock layer in front of a flat-faced cylinder) using 2-D/axisymmetric Navier-Stokes codes and prediction of the radiation spectra from the axisymmetric flowfield using NEQAIR radiation code. Various line-of-sight averaged flow properties such as vibrational and rotational temperatures, species number densities within the shock layer are deduced from the experimental spectra. Comparison of the computed and experimental line-of-sight averaged flow properties provides assessment of thermochemical equilibration processes in an arc-jet shock layer.

Gokcen, T.↗

Spectroscopic Measurement of the Flows in an Arc-Jet Facility

To provide the proper test conditions for various applications, the characteristics of arcjet test facilities should be known. To determine the operational characteristics of an arcjet facility, emission spectroscopy measurements have been performed and analyzed in a previous study. As an extension of the study, radiation from the free stream and the shock layer of 15 cm diameter blunt-body test articles is measured under different test conditions in the NASA Ames 20 MW Arcjet Facility. The test gas is a mixture of argon and air or N2 and argon. To capture the spatially resolved emission spectra along the stagnation streamline of the blunt-body, a CCD camera (1024 x 256 array) with .275 m Czerny-Turner spectrograph is used. The optical system is calibrated in situ using tungsten and deuterium radiation sources. The emission measurements supplement the existing data base and will help provide better understanding of the equilibration processes in the shock layer region.

Park, C. S.↗

Collisional Shift and Broadening of Iodine Spectral Lines in Air Near 543 nm

The collisional processes that influence the absorption of monochromatic light by iodine in air have been investigated. Measurements were made in both a static cell and an underexpanded jet flow over the range of properties encountered in typical compressible-flow aerodynamic applications. Experimentally measured values of the collisional shift and broadening coefficients were 0.058 +/- 0.004 and 0.53 +/- 0.010 GHz K(exp 0.7)/torr, respectively. The measured shift value showed reasonable agreement with theoretical calculations based on Lindholm-Foley collisional theory for a simple dispersive potential. The measured collisional broadening showed less favorable agreement with the calculated value.

Fletcher, D. G.↗

Computational/experimental investigation of staged injection into a Mach 2 flow

The stage normal injection of two jets of air into a Mach 2 freestream behind a rearward-facing step has been investigated using laser-induced iodine fluorescence and laser doppler anemometry techniques. A detailed data set has been compiled that includes profiles of pressure, temperature, two components of velocity, and mole fraction of the injectant at 44 locations, plus planar surveys of pressure, temperature, velocity, and mole fraction. A companion numerical study was performed using the SPARK Navier-Stokes code. Good overall agreement was observed for this complex, highly three-dimensional flowfield. Discrepancies were observed in the computed and measured total temperatures, turbulent mixing, and shock strengths. The effect of grid resolution was investigated by calculating solutions on grids of 60,000 points, 200,000 points, and 450,000 points. Differences in the solutions on the two finer grids were small. The effect of turbulence modeling was investigated by calculating solutions with three different algebraic models for the jet turbulence. Overall, the turbulence models were found to have the greatest effect on the numerical solutions, followed by the grid resolution and the injectant Mach number.

Eklund, D. R.↗

Atomic oxygen fluorescence excitation using a Raman-shifted, tunable ArF-excimer laser

A novel method for exciting the two-photon, 2p3 3p 3P left arrow 2p4 3P atomic oxygen transition is reported. The transition to the upper state is achieved through the combined absorption of photons from the second and third Stokes order pulses of an ArF-excimer laser that is wavelength-shifted by the use of deuterium Raman cell. All three transitions from the ground electronic state of the oxygen atom lie within the tuning range of the Raman-shifted ArF laser. The available pulse energy from this laser configuration is comparable to that of commercially available Nd:YAG-pumped dye laser systems operated at 226 nm.

Fletcher, D. G.↗

Experimental and Computational Study of Sonic and Supersonic Jet Plumes

Study of sonic and supersonic jet plumes are relevant to understanding such phenomenon as jet-noise, plume signatures, and rocket base-heating and radiation. Jet plumes are simple to simulate and yet, have complex flow structures such as Mach disks, triple points, shear-layers, barrel shocks, shock-shear-layer interaction, etc. Experimental and computational simulation of sonic and supersonic jet plumes have been performed for under- and over-expanded, axisymmetric plume conditions. The computational simulation compare very well with the experimental observations of schlieren pictures. Experimental data such as temperature measurements with hot-wire probes are yet to be measured and will be compared with computed values. Extensive analysis of the computational simulations presents a clear picture of how the complex flow structure develops and the conditions under which self-similar flow structures evolve. From the computations, the plume structure can be further classified into many sub-groups. In the proposed paper, detail results from the experimental and computational simulations for single, axisymmetric, under- and over-expanded, sonic and supersonic plumes will be compared and the fluid dynamic aspects of flow structures will be discussed.

Venkatapathy, E.↗

An investigation of nonsimultaneous laser-induced fluorescence

An alternative to simultaneous, two-line laser-induced fluorescence for thermodynamic property measurement is presented. This spectroscopic approach is similar to multiple-overheat hot-wire anemometry and is based on laser excitation of different fluorescence transitions for separate, sequential wind tunnel runs. Both fluctuating and mean thermodynamic property measurements seem to be achievable with this method without exciting the transitions during the same laser pulse.

Fletcher, D. G.↗

Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

Fletcher, D. G.↗

Simultaneous measurements of temperature and density in air flows using UV laser spectroscopy

The simultaneous measurement of temperature and density using laser-induced fluorescence of oxygen in combination with Q-branch Raman scattering of nitrogen and oxygen is demonstrated in a low-speed air flow. The lowest density and temperature measured in the experiment correspond to the freestream values at Mach 5 in the Ames 3.5-Foot Hypersonic Wind Tunnel for stagnation conditions of 100 atm and 1000 K. The experimental results demonstrate the viability of the optical technique for measurements that support the study of compressible turbulence and the validation of numerical codes in supersonic and hypersonic wind tunnel flows.

Fletcher, D. G.↗

Quantitative characterization of a nonreacting, supersonic combustor flowfield using unified, laser-induced iodine fluorescence

A calibrated, nonintrusive optical technique, laser-induced iodine fluorescence (LIIF) was used to quantify the steady, compressible flowfield of a nonreacting, supersonic combustor. The combustor was configured with single and staged, transverse-air injection into a supersonic-air freestream behind a rearward-facing step. Pressure, temperature, two-velocity components, and injectant mole fraction were measured with high spatial resolution in the three-dimensional flowfields. These experimental results provide a benchmark set of data for validation of computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

Fletcher, D. G.↗

Quantitative measurement of transverse injector and free stream interaction in a nonreacting SCRAMJET combustor using laser-induced iodine fluorescence

A preliminary quantitative study of the compressible flowfield in a steady, nonreacting model SCRAMJET combustor using laser-induced iodine fluorescence (LIIF) is reported. Measurements of density, temperature, and velocity were conducted with the calibrated, nonintrusive, optical technique for two different combustor operating conditions. First, measurements were made in the supersonic flow over a rearward-facing step without transverse injection for comparison with calculated pressure profiles. The second configuration was staged injection behind the rearward-facing step at an injection dynamic pressure ratio of 1.06. These experimental results will be used to validate computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

Fletcher, D. G.↗

Temperature measurement in a compressible flow field using laser-induced iodine fluorescence

The thermometric capability of a two-line fluorescence technique using iodine seed molecules in air is investigated analytically and verified experimentally in a known steady compressible flow field. Temperatures ranging from 165 to 295 K were measured in the flowfield using two iodine transitions accessed with a 30-GHz dye-laser scan near 543 nm. The effect of pressure broadening on temperature measurement is evaluated.

Fletcher, D. G.↗