Search NASA⌕ Search

Engineering topics

Fletcher, L. B.

Publications and source records attributed to Fletcher, L. B..

The colliding planar shocks platform to study warm dense matter at the National Ignition Facility

We have developed an experimental platform at the National Ignition Facility that employs colliding planar shocks to produce warm dense matter with uniform conditions and enable high-precision equation of state measurements. The platform uses simultaneous x-ray Thomson scattering and x-ray radiography to measure the density, electron temperature, and ionization state in warm dense matter. The experimental platform is designed to create a large volume of uniform plasma (approximately 700×700×150μm 3 ) at pressures approaching 100 Mbar and minimize the distribution of plasma conditions in the x-ray scattering volume, significantly improving the precision of the measurements. Here, in this study, we present the experimental design of the platform and compare hydrodynamic simulations to x-ray radiography data from initial experiments studying hydrocarbons, producing uniform densities within ±25% of the average probed condition. We show that the platform creates a homogeneous plasma that can be characterized using x-ray Thomson scattering. Thus, the new platform enables accurate measurements of plasma conditions necessary to test models for the equation of state and ionization potential depression in the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observing the onset of pressure-driven K-shell delocalization

The gravitational pressure in many astrophysical objects exceeds one gigabar (one billion atmospheres), creating extreme conditions where the distance between nuclei approaches the size of the K shell. This close proximity modifies these tightly bound states and, above a certain pressure, drives them into a delocalized state. Both processes substantially affect the equation of state and radiation transport and, therefore, the structure and evolution of these objects. Still, our understanding of this transition is far from satisfactory and experimental data are sparse. Here, in this work, we report on experiments that create and diagnose matter at pressures exceeding three gigabars at the National Ignition Facility where 184 laser beams imploded a beryllium shell. Bright X-ray flashes enable precision radiography and X-ray Thomson scattering that reveal both the macroscopic conditions and the microscopic states. The data show clear signs of quantum-degenerate electrons in states reaching 30 times compression, and a temperature of around two million kelvins. At the most extreme conditions, we observe strongly reduced elastic scattering, which mainly originates from K-shell electrons. We attribute this reduction to the onset of delocalization of the remaining K-shell electron. With this interpretation, the ion charge inferred from the scattering data agrees well with ab initio simulations, but it is significantly higher than widely used analytical models predict.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward using collective x-ray Thomson scattering to study C–H demixing and hydrogen metallization in warm dense matter conditions

The insulator–metal transition in liquid hydrogen is an important phenomenon to understand the interiors of gas giants, such as Jupiter and Saturn, as well as the physical and chemical behavior of materials at high pressures and temperatures. Here, the path toward an experimental approach is detailed based on spectrally resolved x-ray scattering, tailored to observe and characterize hydrogen metallization in dynamically compressed hydrocarbons in the regime of carbon–hydrogen phase separation. With the help of time-dependent density functional theory calculations and scattering spectra from undriven carbon samples collected at the European x-ray Free-Electron Laser Facility (EuXFEL), we demonstrate sufficient data quality for observing C–H demixing and investigating the presence of liquid metallic hydrogen in future experiments using the reprated drive laser systems at EuXFEL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recovery of release cloud from laser shock-loaded graphite and hydrocarbon targets: in search of diamonds

Abstract This work presents first insights into the dynamics of free-surface release clouds from dynamically compressed polystyrene and pyrolytic graphite at pressures up to 200 GPa, where they transform into diamond or lonsdaleite, respectively. These ejecta clouds are released into either vacuum or various types of catcher systems, and are monitored with high-speed recordings (frame rates up to 10 MHz). Molecular dynamics simulations are used to give insights to the rate of diamond preservation throughout the free expansion and the catcher impact process, highlighting the challenges of diamond retrieval. Raman spectroscopy data show graphitic signatures on a catcher plate confirming that the shock-compressed PS is transformed. First electron microscopy analyses of solid catcher plates yield an outstanding number of different spherical-like objects in the size range between ten(s) up to hundreds of nanometres, which are one type of two potential diamond candidates identified. The origin of some objects can unambiguously be assigned, while the history of others remains speculative.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron-Ion Temperature Relaxation in Warm Dense Hydrogen Observed With Picosecond Resolved X-Ray Scattering

Angularly resolved X-ray scattering measurements from fs-laser heated hydrogen have been used to determine the equilibration of electron and ion temperatures in the warm dense matter regime. The relaxation of rapidly heated cryogenic hydrogen is visualized using 5.5 keV X-ray pulses from the Linac Coherent Light (LCLS) source in a 1 Hz repetition rate pump-probe setting. We demonstrate that the electron-ion energy transfer is faster than quasi-classical Landau-Spitzer models that use ad hoc cutoffs in the Coulomb logarithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of an x-ray Raman spectroscopy setup to study warm dense carbon at the high energy density instrument of European XFEL

We present a proof-of-principle study demonstrating x-ray Raman Spectroscopy (XRS) from carbon samples at ambient conditions in conjunction with other common diagnostics to study warm dense matter, performed at the high energy density scientific instrument of the European x-ray Free Electron Laser (European XFEL). We obtain sufficient spectral resolution to identify the local structure and chemical bonding of diamond and graphite samples, using highly annealed pyrolytic graphite spectrometers. Due to the high crystal reflectivity and XFEL brightness, we obtain signal strengths that will enable accurate XRS measurements in upcoming pump–probe experiments with a high repetition-rate, where the samples will be pumped with high-power lasers. Molecular dynamics simulations based on density functional theory together with XRS simulations demonstrate the potential of this technique and show predictions for high-energy-density conditions. Our setup allows simultaneous implementation of several different diagnostic methods to reduce ambiguities in the analysis of the experimental results, which, for warm dense matter, often relies on simplifying model assumptions. The promising capabilities demonstrated here provide unprecedented insights into chemical and structural dynamics in warm dense matter states of light elements, including conditions similar to the interiors of planets, low-mass stars, and other celestial bodies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the structure and equation of state of polyethylene terephthalate at megabar pressures

Abstract We present structure and equation of state (EOS) measurements of biaxially orientated polyethylene terephthalate (PET, $$({\hbox {C}}_{10} {\hbox {H}}_8 {\hbox {O}}_4)_n$$ ( C 10 H 8 O 4 ) n , also called mylar) shock-compressed to ( $$155 \pm 20$$ 155 ± 20 ) GPa and ( $$6000 \pm 1000$$ 6000 ± 1000 ) K using in situ X-ray diffraction, Doppler velocimetry, and optical pyrometry. Comparing to density functional theory molecular dynamics (DFT-MD) simulations, we find a highly correlated liquid at conditions differing from predictions by some equations of state tables, which underlines the influence of complex chemical interactions in this regime. EOS calculations from ab initio DFT-MD simulations and shock Hugoniot measurements of density, pressure and temperature confirm the discrepancy to these tables and present an experimentally benchmarked correction to the description of PET as an exemplary material to represent the mixture of light elements at planetary interior conditions.

36 MATERIALS SCIENCE↗

Demonstration of a laser-driven, narrow spectral bandwidth x-ray source for collective x-ray scattering experiments

X-ray Thomson scattering (XRTS) is a powerful diagnostic technique that involves an x-ray source interacting with a dense plasma sample, resulting in a spectrum of elastically and inelastically scattered x-rays. Depending on the plasma conditions, one can measure a range of parameters from the resulting spectrum, including plasma temperature, electron density, and ionization state. To achieve sensitivity to collective electron oscillations, XRTS measurements require limited momentum transfer where the spectral separation of elastic and inelastic scattering is small. Such measurements require an x-ray probe source with a narrow bandwidth in order to reduce the spectral overlap between scattering contributions, allowing for the different features to be more precisely deconvolved. In this investigation, we discuss the theory behind how the bandwidth for a common XRTS probe, Zn He-α emission at 9 keV, can be reduced using a Cu K-edge filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray free electron laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using simultaneous x-ray diffraction and velocity interferometry to determine material strength in shock-compressed diamond

We determine the strength of laser shock-compressed polycrystalline diamond at stresses above the Hugoniot elastic limit using a technique combining x-ray diffraction from the Linac Coherent Light Source with velocity interferometry. X-ray diffraction is used to measure lattice strains, and velocity interferometry is used to infer shock and particle velocities. These measurements, combined with density-dependent elastic constants calculated using density functional theory, enable determination of material strength above the Hugoniot elastic limit. Furthermore, our results indicate that diamond retains approximately 20 GPa of strength at longitudinal stresses of 150–300 GPa under shock compression.

36 MATERIALS SCIENCE↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray Free Electron Laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray Free Electron Laser using inelastic X-ray scattering. The experiment was performed at the High Energy Density (HED) instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of diamond nucleation rates from hydrocarbons at conditions comparable to the interiors of icy giant planets

We present measurements of the nucleation rate into a diamond lattice in dynamically compressed polystyrene obtained in a pump-probe experiment using a high-energy laser system and in situ femtosecond x-ray diffraction. Different temperature-pressure conditions that occur in planetary interiors were probed. For a single shock reaching 70 GPa and 3000 K no diamond formation was observed, while with a double shock driving polystyrene to pressures around 150 GPa and temperatures around 5000 K nucleation rates between 10 29 and 10 34 m –3 s –1 were recorded. These nucleation rates do not agree with predictions of the state-of-the-art theoretical models for carbon-hydrogen mixtures by many orders of magnitude. Our data suggest that there is significant diamond formation to be expected inside icy giant planets like Neptune and Uranus.

43 PARTICLE ACCELERATORS↗