Search NASA⌕ Search

Engineering topics

Fletcher, L. B. (ORCID:0000000271207194)

Publications and source records attributed to Fletcher, L. B. (ORCID:0000000271207194).

Observation of a mixed close-packed structure in superionic water

The study of superionic (SI) water has been a highly active research area since its theoretical prediction. Despite significant experimental and computational efforts, its melting curve and the stability of different oxygen lattices remain debated, impacting our understanding of SI ice’s peculiar transport properties. Experimental results at lower pressures show disagreement, whereas data at higher pressures are scarce due to the extreme challenges of such experiments. In this work, we present ultrafast X-ray diffraction results of water compressed by multiple shocks to pressures up to ~ 180 GPa. At pressures exceeding 150 GPa and temperatures around 2500 K, our diffraction patterns challenge the pure FCC-SI phase model, providing experimental evidence of the mixed close-packed superionic phase predicted by advanced ab initio calculations. At lower pressures, we observe simultaneous signatures of BCC and FCC structures within a pressure-temperature range consistent with some static-compression experiments, helping to resolve contradictory results in literature. These insights offer new constraints on the stability domains of SI phases and reveal detailed structural features, such as stacking faults. Our results advance the structural understanding of high-pressure SI ice to a level approaching that of ice I polymorphs, with potential implications for water-rich interiors of giant planets.

Andriambariarijaona, Leon [Centre National de la R↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

DC electrical conductivity measurements of warm dense matter using ultrafast THz radiation

We describe measurements of the DC electrical conductivity of warm dense matter using ultrafast terahertz (THz) pulses. THz fields are sufficiently slowly varying that they behave like DC fields on the timescale of electron–electron and electron–ion interactions and hence probe DC-like responses. Using a novel single-shot electro-optic sampling technique, the electrical conductivity of the laser-generated warm dense matter was determined with <1 ps temporal resolution. We present the details of the single-shot THz detection methodology as well as considerations for warm dense matter experiments. We, then, provide proof-of-concept studies on aluminum driven to the warm dense matter regime through isochoric heating and shock compression. Our results indicate a decrease in the conductivity when driven to warm dense matter conditions and provide a platform for future warm dense matter studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗