Search NASA⌕ Search

Engineering topics

Fonte, P.

Publications and source records attributed to Fonte, P..

Breakdown Limit Studies in High-Rate Gaseous Detectors

We report results from a systematic study of breakdown limits for novel high-rate gaseous detectors: MICROMEGAS, CAT and GEM, together with more conventional devices such as thin-gap parallel-mesh chambers and high-rate wire chambers. It was found that for all these detectors, the maximum achievable pin, before breakdown appears, drops dramatically with incident flux, and is sometimes inversely proportional to it. Further, in the presence of alpha particles, typical of the breakgrounds in high-energy experiments, additional gain drops of 1-2 orders of magnitude were observed for many detectors. It was found that breakdowns at high rates occur through what we have termed an "accumulative" mechanism, which does not seem to have been previously reported in the literature. Results of these studies may help in choosing the optimum detector for given experimental conditions.

Ivaniouchenkov, Yu↗

Rate and Gain Limitations of MSGC's and MGC's Combined with GEM and other Preamplification Structures

We have studied the rate and gain limits of diamond-coated Microstrip Gas Counters (MSGC's) and Micro-Gap Counters (MGC's) when combined with various preamplification structures: Gas Electron Multiplier (GEM), Parallel-Plate Avalanche Chamber (PPAC) or a MICROMEGAS-type structure. Measurements were done both with X rays and alpha particles with various detector geometries and in different gas mixtures at pressures from 0.05 to 10 atm. The results obtained varied significantly with detector design, gas mixture and pressure, but some general features can be identified. We found that in all cases, bare MSGC'S, MGC'S, PPAC's and MICROMEGAS, the maximum achievable gain drops with rate. The addition of preamplification structures significantly increases the gain of MSGC's and MGC'S, but this gain is still rate dependent. There would seem to be a general rate-dependent effect governing the usable gain of all these detectors. We speculate on possible mechanisms for this effect, and identify a safe, spark-free, operation zone for each system (detector + preamplification structure) in the rate-gain coordinate plane.

Fonte, P.↗

Breakdown Features of Various Microstrip-Type Gas Counter Designs and Their Improvements

Breakdown mechanisms and spurious pulses, the precursors to some breakdowns, were studied experimentally for both uncoated and coated Microstrip Gas Counters (MSGCs) of different geometries, as well as for MicroGap Counters (MGCs) and for the "Compteur A Trou" (CAT). It was found that in all cases the breakdowns occurred through surface streamers, although the exact mechanism of streamer formation depended on the particular detector design. Based on these studies, new designs of microstrip detectors, in which the role of the substrate was minimized, were elaborated and tested. In some of these detectors, especially with large pitches (greater than 2mm), gains up to 2-3 x 10(exp 5) were achieved together with good rate characteristics. The ultimate gain limit in all geometries was still set by spark-inducing streamers which appeared at some critical charge density in the avalanche. To avoid this, and particularly to enhance the performance of small-pitch MSGCs, preamplification structures can be used. Utilizing a parallel plate avalanche chamber as a front end to an MSGC resulted in an overall gain of approximately 10(exp 6), limited in this case only by charge saturation.

Peskov, V.↗

A Study of Breakdown Limits in Microstrip Gas Counters with Preamplification Structures

We have studied the charge and breakdown limits of Microstrip Gas Counters (MSGCs) with 2 different preamplification structures: the Gas Electron Multiplier (GEM) and the Parallel-Plate Avalanche Counter (PPAC). It was found that in both cases the breakdown limit was increased by 1-2 orders of magnitude compared to the bare MSGC that this is due to the spread of the primary electron cloud during pre-amplification. This spreading reduces the charge density in the final MSGC avalanche, permitting much higher total gains before streamers form. The real practical gain limitations in these two-stage detectors arose not from sparking, but from a loss of proportionality due to space charge effects.

Fonte, P.↗