Search NASA⌕ Search

Engineering topics

Ford, Michael

Publications and source records attributed to Ford, Michael.

National Council on Radiation Protection (NCRP) 2024 annual meeting: advanced and small modular nuclear power reactors

On 25–26 March 2023, the U.S. National Council on Radiation Protection and Measurements (NCRP) held its 2024 annual meeting in Bethesda, Maryland, USA. The NCRP dates from 1929, and this meeting celebrated the 60th anniversary of receiving a U.S. Congressional Charter. For this annual meeting the NCRP felt it was essential to provide a briefing about advanced and small modular nuclear reactors (SMRs). The Journal of Radiological Protection is delighted to publish the following synopsis of material presented at the U.S. NCRP meeting. This synopsis is divided into five sections. The first section provides an overview of the whole meeting together with summaries of two context setting overview papers. The following four sessions of this synopsis are specific to advanced and small modular nuclear power reactors. The meeting also included keynote presentations by three of NCRP annual award recipients. The meeting topical areas were Technology Overview and Critical Issues. The individual papers laid the groundwork to understanding reactor technologies, terminology, and the fundamental concepts and processes for electrical generation. The perspectives of the U.S. Environmental Protection Agency and states, through the Conference of Radiation Control Program Directors were provided. The papers included a discussion of diverse topics including potential emergency preparedness considerations, radiological survey requirements, an evaluation of the future of nuclear power, the economics of reactors (both large and small), and the critical issues identified by the recent National Academies of Sciences’ study on advanced reactors. Here, the summary papers were developed to briefly document the major points and concepts presented during the oral papers presented at the 2024 NCRP Annual Meeting. The meeting heralded the dawn of a new era for commercial nuclear power.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE↗

STAND Quickstart Guide

STAND is a flexible web application designed to identify and examine potentially feasible sites where advanced nuclear facilities might be welcomed by host communities. STAND allows the user to explore and provide insight on socioeconomic, proximity, and safety data, generate county reports, review regulatory data, and complete a comparative analysis across multiple sites by following several paths, either individually or sequentially based on the user’s needs and where they are in the deployment process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STAND Quickstart Guide

STAND is a flexible web application designed to identify and examine potentially feasible sites where advanced nuclear facilities might be welcomed by host communities. STAND allows the user to explore and provide insight on socioeconomic, proximity, and safety data, generate county reports, review regulatory data, and complete a comparative analysis across multiple sites by following several paths, either individually or sequentially based on the user’s needs and where they are in the deployment process. STAND is best used for the contiguous United States. STAND is not a substitute for the in-depth studies required to qualify a site for hosting a nuclear facility, nor is it a substitute for the necessary community engagement to build trust and seek consent. It can, however, be a valuable resource to aid in the siting process.

99 GENERAL AND MISCELLANEOUS↗

Future Advances in Photon-Based Neutrino Detectors: A SNOWMASS White Paper

We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physics programs in hybrid Cherenkov/scintillation detectors, such as slow fluors, water-based liquid scintillator, and spectral sorting of photons. Several new large-scale detector ideas are also discussed, including hybrid detectors like Theia, ArTEMIS, and generic slow-fluor detectors, as well as the very different SLIPs and LiquidO approaches to instrumenting photon-based detectors. A program of demonstrators for future detectors, including ANNIE, Eos, and NuDOT are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Balance Between Light Absorption and Recombination Losses in Solution‐Processed Small Molecule Solar Cells with Normal or Inverted Structures

Abstract Comparison of the photovoltaic properties of F3:fullerene bulk heterojunction solar cells (where F3 is a donor molecule of intermediate dimensions) with normal and inverted structures as a function of photoactive layer thickness is carried out by using optical modeling and light‐dependent photoelectrical characterization. The larger short circuit current of inverted devices can be explained by higher light absorption in the active layer, relative to normal devices. However, worse charge extraction conditions and trap‐assisted recombination, in the bulk heterojunction blend in inverted devices, give rise to larger nongeminate recombination losses and an opposite thickness dependence of the short circuit current and fill factor than what is observed in counterparts with the conventional device architecture.

Brus, Viktor V.↗

Bandgap Narrowing in Non‐Fullerene Acceptors: Single Atom Substitution Leads to High Optoelectronic Response Beyond 1000 nm

Abstract Two narrow bandgap non‐fullerene acceptors (NBG‐NFAs), namely, COTIC‐4F and SiOTIC‐4F, are designed and synthesized for the fabrication of efficient near‐infrared organic solar cells (OSCs). The chemical structures of the NBG‐NFAs contain a D′‐D‐D′ electron‐rich internal core based on a cyclopentadithiophene (or dithienosilole) (D) and alkoxythienyl (D′) core, end‐capped with the highly electron‐deficient unit 2‐(5,6‐difluoro‐3‐oxo‐2,3‐dihydro‐1H‐inden‐1‐ylidene)malononitrile (A), ultimately providing a A‐D′‐D‐D′‐A molecular configuration that enhances the intramolecular charge transfer characteristics of the excited states. One can thereby reduce the optical bandgap ( E g opt ) to as low as ≈1.10 eV, one of the smallest values for NFAs reported to date. In bulk‐heterojunction (BHJ) OSCs, NBG‐NFA blends with the polymer donor PTB7‐Th yield power conversion efficiencies (PCE) of up to 9.0%, which is particularly high when compared against a range of NBG BHJ blends. Most significantly, it is found that, despite the small energy loss ( E g opt − e V OC ) of 0.52 eV, the PTB7‐Th/NBG‐NFA bulk heterojunction blends can yield short‐circuit current densities of up to 22.8 mA cm −2 , suggesting that the design and application of NBG‐NFA materials have substantial potential to further improve the PCE of OSCs.

Lee, Jaewon↗

Effect of chiral 2-ethylhexyl side chains on chiroptical properties of the narrow bandgap conjugated polymers PCPDTBT and PCDTPT

Two narrow bandgap conjugated polymers containing chiral 2-ethylhexyl side chains were synthesized: poly[(4,4-bis(2-ethylhexyl)cyclopenta-[2,1-b:3,4-b']dithiophene)-2,6-diyl-alt-(2,1,3-benzothiadiazole)-4,7-diyl] (PCPDTBT*) and poly[(4,4-bis(2-ethylhexyl)cyclopenta[2,1-b:3,4-b0]dithiophene)-2,6-diyl-alt-[1,2,5]-thiadiazolo[3,4-c]pyridine] (PCDTPT*). The presence of a chiral substituent provides a handle to study the geometry of interchain aggregates and/or the secondary structure of these conjugated polymers in solution and in thin films via circular dichroism (CD) spectroscopy, provided that the asymmetry in the side-chain is translated to the optically active conjugated backbone. CD signals are observed for PCPDTBT* and PCDTPT* in poor solvent systems, which indicate the presence of chiral ordering in the aggregates. PCPDTBT* shows greater chiral order than PCDTPT* based on their relative anisotropy factors. Additionally, GIWAXS analysis reveals that PCPDTBT* films are more ordered than what is observed for the same polymer containing racemic 2-ethylhexyl chains. Upon solution deposition, the chiral ordering is found to translate to the solid-state microstructure for PCPDTBT* but not PCDTPT*. The presence of a pyridyl nitrogen on the thiadiazolo[3,4-c]pyridine ring of PCDTPT* favors a planar conformation for the backbone such that it has a higher rotational barrier compared to PCPDTBT*. This larger rotational barrier appears to limit the ability of PCDTPT* to adopt a helical structure or relevant chain distortions for achieving chiral aggregates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A 2011 Updated Systematic Review and Clinical Practice Guideline for the Management of Malignant Extradural Spinal Cord Compression

Purpose: To update the 2005 Cancer Care Ontario practice guidelines for the diagnosis and treatment of adult patients with a suspected or confirmed diagnosis of extradural malignant spinal cord compression (MESCC). Methods: A review and analysis of data published from January 2004 to May 2011. The systematic literature review included published randomized control trials (RCTs), systematic reviews, meta-analyses, and prospective/retrospective studies. Results: An RCT of radiation therapy (RT) with or without decompressive surgery showed improvements in pain, ambulatory ability, urinary continence, duration of continence, functional status, and overall survival. Two RCTs of RT (30 Gy in eight fractions vs. 16 Gy in two fractions; 16 Gy in two fractions vs. 8 Gy in one fraction) in patients with a poor prognosis showed no difference in ambulation, duration of ambulation, bladder function, pain response, in-field failure, and overall survival. Retrospective multicenter studies reported that protracted RT schedules in nonsurgical patients with a good prognosis improved local control but had no effect on functional or survival outcomes. Conclusions: If not medically contraindicated, steroids are recommended for any patient with neurologic deficits suspected or confirmed to have MESCC. Surgery should be considered for patients with a good prognosis who are medically and surgically operable. RT should be given to nonsurgical patients. For those with a poor prognosis, a single fraction of 8 Gy should be given; for those with a good prognosis, 30 Gy in 10 fractions could be considered. Patients should be followed up clinically and/or radiographically to determine whether a local relapse develops. Salvage therapies should be introduced before significant neurologic deficits occur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Computed Tomography Imaging Features With Pain Response in Patients With Spine Metastases After Radiation Therapy

Purpose: To correlate computed tomography (CT) imaging features of spinal metastases with pain relief after radiotherapy (RT). Methods and Materials: Thirty-three patients receiving computed tomography (CT)-simulated RT for spinal metastases in an outpatient palliative RT clinic from January 2007 to October 2008 were retrospectively reviewed. Forty spinal metastases were evaluated. Pain response was rated using the International Bone Metastases Consensus Working Party endpoints. Three musculoskeletal radiologists and two orthopaedic surgeons evaluated CT features, including osseous and soft tissue tumor extent, presence of a pathologic fracture, severity of vertebral height loss, and presence of kyphosis. Results: The mean patient age was 69 years; 24 were men and 9 were women. The mean worst pain score was 7/10, and the mean total daily oral morphine equivalent was 77.3 mg. Treatment doses included 8 Gy in one fraction (22/33), 20 Gy in five fractions (10/33), and 20 Gy in eight fractions (1/33). The CT imaging appearance of spinal metastases included vertebral body involvement (40/40), pedicle involvement (23/40), and lamina involvement (18/40). Soft tissue component (10/40) and nerve root compression (9/40) were less common. Pathologic fractures existed in 11/40 lesions, with resultant vertebral body height loss in 10/40 and kyphosis in 2/40 lesions. At months 1, 2, and 3 after RT, 18%, 69%, and 70% of patients experienced pain relief. Pain response was observed with various CT imaging features. Conclusions: Pain response after RT did not differ in patients with and without pathologic fracture, kyphosis, or any other CT features related to extent of tumor involvement. All patients with painful spinal metastases may benefit from palliative RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗