Search NASA⌕ Search

Engineering topics

Formaggio, J. A.

Publications and source records attributed to Formaggio, J. A..

Sterile-neutrino search based on 259 days of KATRIN data

Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial part in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, shows that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact through the weak force. The Karlsruhe Tritium Neutrino (KATRIN) experiment, primarily designed to measure the neutrino mass using tritium β-decay, also searches for sterile neutrinos suggested by these anomalies. A sterile-neutrino signal would appear as a distortion in the β-decay energy spectrum, characterized by a discontinuity in curvature (kink) related to the sterile-neutrino mass. This signature, which depends only on the shape of the spectrum rather than its absolute normalization, offers a robust, complementary approach to reactor experiments. Here we report the analysis of the energy spectrum of 36 million tritium β-decay electrons recorded in 259 measurement days within the last 40 eV below the endpoint. The results exclude a substantial part of the parameter space suggested by the gallium anomaly and challenge the Neutrino-4 claim. Together with other neutrino-disappearance experiments, KATRIN probes sterile-to-active mass splittings from a fraction of an eV 2 to several hundred eV 2 , excluding light sterile neutrinos with mixing angles above a few per cent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment

The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after 5 years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN’s main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The complex layout of electromagnetic fields in the SAP configuration requires a robust method of estimating these fields. We present in this paper a dedicated calibration measurement of the fields using conversion electrons of gaseous 83m Kr, which enables the neutrino-mass measurements in the SAP configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep learning based event reconstruction for cyclotron radiation emission spectroscopy

The objective of the cyclotron radiation emission spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time–frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization—may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment—a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium β - -decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Characterization of TES-Based Detectors for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE nu NS) offers a valuable approach in searching for physics beyond the standard model. The Ricochet experiment aims to perform a precision measurement of the CE nu NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass of around 30 g and an energy threshold of below 100 eV. The array includes nine detectors read out by transition-edge sensors (TES). These TES-based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article, we present an update on the characterization and modeling of a prototype TES detector.

Chang, C. L.↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for keV-scale sterile neutrinos with the first KATRIN data

In this work we present a keV-scale sterile-neutrino search with a low-tritium-activity data set of the KATRIN experiment, acquired in a commissioning run in 2018. KATRIN performs a spectroscopic measurement of the tritium β-decay spectrum with the main goal of directly determining the effective electron anti-neutrino mass. During this commissioning phase a lower tritium activity facilitated the measurement of a wider part of the tritium spectrum and thus the search for sterile neutrinos with a mass of up to 1.6 keV. We do not find a signal and set an exclusion limit on the sterile-to-active mixing amplitude of $\text {sin}^{2}\: \theta<5\times 10^{-4}\: (95\%\: $C.L) at a mass of 0.3 keV. This result improves current laboratory-based bounds in the sterile-neutrino mass range between 0.1 and 1.0 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗