Search NASA⌕ Search

Engineering topics

Francis M Mccubbin

Publications and source records attributed to Francis M Mccubbin.

Understanding Mercury’s Magmatic History: Geochemical Affinity, Compatibility, & Volatility Changes Due to Reduction

Mercury’s depletion in O and abundance of S substituting in as S2- has fundamental effects on the physicochemical properties of minerals and melts because O2- is the dominant rock-forming anion. These changes exert a first order effect on planetary body evolution, including the initial distribution of elements, crystallization paths, stability of phases, and mineral chemistry. Experimental and empirical data have revealed that most nominally lithophile elements become more chalcophile and/or siderophile at reducing conditions, which can be visualized through a re-interpreted Goldschmidt classification table prepared for McCubbin & Anzures’s Treatises of Geochemistry 3rd edition chapter under review. Additionally, the S bonding environment influences Mercurian phase equilibria by decreasing the stability of forsterite and anorthite while increasing the stability of enstatite, silica, and albite through re-projection of silicate ternaries.

Brendan Anthony Anzures↗

MSR Science Planning Group 2 (MSPG2): Science & Curation Considerations for Time Sensitive Measurements That Should be Performed in Containment

The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.

Aaron B Regberg↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Stable Chlorine Isotope Measurements of Astromaterials Using the Cs-Sputter Negative Ion Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) [1] are documented to exceed 80‰ [2] between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history[3,4].The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements (Figure 1).This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the Cs-sputter negative ion source of an existing accelerator mass spectrometer. A brief description of the methods used for this work is followed by the results of our δ37Cl measurements and a discussion of the technique’s possible applications.

Chlorine↗

Silicon Partitioning Between Iron-Rich Metal and Silicate Melt: New Constraints From Aerodynamic Laser Levitation Furnace Experiments

The partitioning of light elements (e.g., Si, C, H, etc.) between silicate melts and iron metal alloys as a function of pressure and temperature is a critical constraint in defining the compositional evolution of planetary interiors. While there are a significant number of experimental studies in the literature that examine the various influences of oxygen fugacity, temperature, pressure, and composition on the metal-melt partitioning of silicon, it is difficult to disentangle the effects of each variable due to the nominally independent parameters (e.g., pressure, temperature, composition) being collinear. To better test for the independent effects of pressure, temperature, and melt composition on the partitioning of silicon between iron alloy and silicate melt, new high temperature (1800°–2500°C), rapid quench (~700°C/s) aerodynamic levitation laser-heating experiments in the Fe-Si-Mg-O (En65-Fa5-Si3-Fe27) system were conducted. This high temperature, low pressure method is ideal for these experiments because it eliminates the metal container as a sink for elements of interest to partition into, and it has a rapid quench rate that minimizes potential exsolution of silicon from the metal phase during quench cooling. Given the short run times of the levitation experiments (30–60 seconds), a time series at a lower temperature (1700°C) in a vertical gas-mixing muffle tube furnace was also conducted to assess equilibrium times of the bulk composition. All successful runs were imaged using back-scatter electron imaging and analyzed for phase composition using a JEOL 8530F field emission microprobe. These new data were added to a comprehensive and internally consistent data set created from published experiments, and subsequently modeled using parameters designed to minimize collinearity (e.g., optical basicity is used as a proxy for melt composition). High collinearity is found in the data set however between temperature and oxygen fugacity, precluding any model that contains both as nominally independent variables. The resulting model demonstrates a statistically significant effect of pressure, temperature, and melt composition on the partitioning of silicon in Fe-rich metal, which has implications for the formation of planetary cores in rocky planets and provides important constraints on potential bulk core compositions.

Metal↗

OSIRIS-REx Curation: The First Year with Bennu Samples on Earth

The OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security – Regolith Explorer) sample return capsule landed on the Utah Test and Training Range (UTTR) on September 24, 2023. Preparations for the curation of the sample from asteroid Bennu inside of this capsule spanned more than a decade. On the morning of landing, the sample return capsule was brought to a temporary cleanroom at UTTR for initial de-integration and connection of the sample canister to a nitrogen gas purge to protect the sample from modification by the terrestrial atmosphere. In the week following landing, the sample canister was flown to Houston while on nitrogen purge, transferred to a nitrogen atmosphere glovebox at NASA Johnson Space Center in which the canister lid was removed revealing small amounts of sample on the inside of the canister lid and avionics deck, some of this sample was allocated rapidly to the mission sample analysis team as “quick look” samples. Next, the Touch-and-Go sample acquisition mechanism (TAGSAM) head was disassembled inside of a specially designed glovebox. A challenge arose during one of the last stages of disassembly when two fasteners resisted being loosened. The curation team was able to remove 70.3 grams of asteroid sample from the TAGSAM head with those fasteners in-place and began initial sample processing which supported long-term curation of hermetically sealed and frozen samples, transfer of some samples to remote storage, and allocation of aggregate samples to the mission sample analysis team. Meanwhile, curation engineers developed a tool to remove the stubborn fasteners without contaminating the remaining sample, enabling the remaining bulk sample to be transferred to long-term storage trays in January 2024. With this second part of the bulk sample, the returned bulk asteroid sample reached 121.6 grams. During disassembly and prior to sealing the bulk sample trays into long-term storage containers, archival photographs were collected. Select particles are gradually being XCT scanned while inside of containers that hold a nitrogen atmosphere. The initial OSIRIS-REx sample catalog was released in spring 2024 with an update in fall 2024. The curation team will be busy working to allocate samples to scientists around the world for the foreseeable future.

Curation↗