In Situ Synchrotron Micro-CT of Microballoon-Filled RTV Silicone During Thermal Decomposition
This work investigates the thermal decomposition of microballoon-filled room-temperature-vulcanizing (RTV) silicone using time-resolved synchrotron micro-CT at the Advanced Light Source. In situ imaging of constrained and unconstrained samples captures the evolution of the internal microstructure during heating, including material expansion, microballoon and void growth, tearing, pyrolysis, shrinkage, and increasing porosity. The measurements provide new insight into the mechanisms governing RTV degradation and generate three-dimensional data for future quantitative analysis and material-response model development.