Search NASA⌕ Search

Engineering topics

Francisco, Paul W.

Publications and source records attributed to Francisco, Paul W..

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Assessment of Radon Reduction Interventions with Energy Retrofits Expansion (The BEX Study): Final Report

This report presents the findings from a study that was performed to assess whether current precautionary measures used by the US Department of Energy Weatherization Assistance Program (WAP) are effective for preventing indoor radon increases following weatherization. The study results show that current practices have produced substantial benefit compared to previous practices, and that there are no statistically significant changes in indoor radon levels on the lowest living levels with these practices following weatherization.

07 ISOTOPE AND RADIATION SOURCES↗