Search NASA⌕ Search

Engineering topics

Frank Palmieri

Publications and source records attributed to Frank Palmieri.

At least 19 records

Surface Characterization of Carbon Fiber Reinforced Polymers by Picosecond Laser Induced Breakdown Spectroscopy

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants as part of a vigorous quality control process to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding are essential in order to obtain a surface which is free from contaminants that may lead to inferior bond quality. In this study, the focus is to advance the laser induced breakdown spectroscopy (LIBS) technique by using pulse energies below 100 μJ (μLIBS) for the detection of low levels of silicone contaminants in carbon fiber reinforced polymer (CFRP) composites. Various CFRP surface conditions were investigated by LIBS using ∼10 ps, 355 nm laser pulses with pulse energies below 30 μJ. Time-resolved analysis was conducted to optimize the gate delay and gate width for the detection of the C I emission line at 247.9 nm to monitor the epoxy resin matrix of CFRP composites and the Si I emission line at 288.2 nm for detection of silicone contaminants in CFRP. To study the surface sensitivity to silicone contamination, CFRP surfaces were coated with polydimethylsiloxane (PDMS), the active ingredient in many mold release agents. The presence of PDMS was studied by inspecting the Si I emission lines at 251.6 nm and 288.2 nm. The measured PDMS areal densities ranged from 0.15 to 2 μg/cm(sup 2). LIBS measurements were performed before and after laser surface ablation. The results demonstrate the successful detection of PDMS thin layers on CFRP using picosecond μLIBS.

Rodolfo Ledesma↗

TPSAS-NF1676L-24485-DND

Hybrid composite laminates that contain alternating layers of titanium alloys and carbon fabric reinforced polyimide matrix composites (PMC) are excellent candidates for light-weight, high-temperature structural materials for high-speed aerospace vehicles. The delamination resistance of the hybrid titanium-PMC interface is of crucial consideration for structural integrity during service. Here, we report the first investigations on the use of laser ablation in combination with sol-gel treatment technique on Ti/NiTi foil surfaces in co-cured hybrid polyimide matrix composite laminates. Mode-I and mode-II fracture toughness of the hybrid Ti/NiTi-PMC interface as a function of temperature were determined via experimental testing and finite element analysis.

John Connell↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

CAS: AERoBOND Overview

Explore the source record for details and available documents.

Frank Palmieri↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

Closed-Loop Control of Laser Surface Treatment via Laser Induced Breakdown Spectroscopy

Current composite manufacturing rates need to be improved to meet the projected demand of on-demand mobility (ODM) and commercial aircraft transports. Some processes in the composite manufacturing chain require touch labor such as manual sanding of surfaces prior to bonding and installing thousands of mechanical fasteners in bonded primary structures to achieve Federal Aviation Administration (FAA) certification. The consequences are insufficient repeatability in bond quality resulting in increased manufacturing time. The FAA has indicated that robust process control is one potential means of certifying bondlines in primary structure. This work describes an integrated closed-loop control system between a laser machining system and laser induced breakdown spectroscopy (LIBS) instrumentation as a means of assuring bond performance and achieving certified composite bondlines. Preliminary results from in-situ treatment and inspection are presented. Results indicate that LIBS inspection and laser treatment can be conducted simultaneously to achieve high quality, reliable adhesive bonds.

Rodolfo Ledesma↗

Closed-Loop Control of Laser Surface Treatment via Laser Induced Breakdown Spectroscopy

Current composite manufacturing rates need to be improved to meet the projected demand of on-demand mobility (ODM) and commercial aircraft transports. Some processes in the composite manufacturing chain require touch labor such as manual sanding of surfaces prior to bonding and installing thousands of mechanical fasteners in bonded primary structures to achieve Federal Aviation Administration (FAA) certification. The consequences are insufficient repeatability in bond quality resulting in increased manufacturing time. The FAA has indicated that robust process control is one potential means of certifying bondlines in primary structure. This work describes an integrated closed-loop control system between a laser machining system and laser induced breakdown spectroscopy (LIBS) instrumentation as a means of assuring bond performance and achieving certified composite bondlines. Preliminary results from in-situ treatment and inspection are presented. Results indicate that LIBS inspection and laser treatment can be conducted simultaneously to achieve high quality, reliable adhesive bonds.

Rodolfo Ledesma↗