Search NASA⌕ Search

Engineering topics

Freeman, Charles J.

Publications and source records attributed to Freeman, Charles J..

At least 19 records

Microchannel reactive distillation for the conversion of aqueous ethanol to ethylene

Here we demonstrate the proof-of-concept for microchannel reactive distillation for alcohol-to-jet application: combining ethanol/water separation and ethanol dehydration in one unit operation. Ethanol is first distilled into the vapor phase, converted to ethylene and water, and then the water co-product is condensed to shift the reaction equilibrium. Process intensification is achieved through rapid mass transfer—ethanol stripping from thin wicks using novel microchannel architectures—leading to lower residence time and improved separation efficiency. Energy savings are realized with integration of unit operations. For example, heat of condensing water can offset vaporizing ethanol. Furthermore, the dehydration reaction equilibrium shifts towards completion by immediate removal of the water byproduct upon formation while maintaining aqueous feedstock in the condensed phase. For aqueous ethanol feedstock (40% w ), 71% ethanol conversion with 91% selectivity to ethylene was demonstrated at 220 °C, 600 psig, and 0.28 h -1 wt hour space velocity. 2.7 stages of separation were also demonstrated, under these conditions, using a device length of 8.3 cm. This provides a height equivalent of a theoretical plate (HETP), a measure of separation efficiency, of ~3.3 cm. By comparison, conventional distillation packing provides an HETP of ~30 cm. Thus, 9.1× reduction in HETP was demonstrated over conventional technology, providing a means for significant energy savings and an example of process intensification. Finally, preliminary process economic analysis indicates that by using microchannel reactive distillation technology, the operating and capital costs for the ethanol separation and dehydration portion of an envisioned alcohol-to-jet process could be reduced by at least 35% and 55%, respectively, relative to the incumbent technology, provided future improvements to microchannel reactive distillation design and operability are made.

10 SYNTHETIC FUELS↗

DISH-STARS™ Commercialization (Abstract)

The goal of this project is to aggressively support the near-term commercialization of a new technology platform – based on the integration of solar concentrators and micro- and meso-channel process technology (MMPT) – that was evaluated and identified as a strong candidate for near-term commercialization at EERE’s inaugural Lab-Corps program during early FY2016. Known as STARS, for Solar Thermochemical Advanced Reactor System, or Dish-STARS™ when paired with parabolic dish concentrators, STARS is a promising energy-related technology developed at the Pacific Northwest National Laboratory (PNNL) that efficiently converts solar energy into chemical energy. Combined with economies through hardware mass production, the efficiency of Dish-STARS™ provides a near-term opportunity for the production of renewable electricity, fuels and chemicals. This proposed CRADA project supports the commercialization of Dish-STARS™ in these important ways: The project will support the cooperative development of Dish-STARS™ by the DOE national laboratory and private partners, including the startup company, STARS Corporation, that is being established by the PNNL Lab-Corps team that evaluated STARS on behalf of EERE. The project will provide important transition funding at the time that the previous DOE SunShot project, which has supported Dish-STARS™ development from Technology Readiness Level 3 (TRL 3) to TRL 6, is scheduled to end.

14 SOLAR ENERGY↗

Methodology for assessing the maximum potential impact of separations opportunities in industrial processes

Separation technologies currently used in U.S. manufacturing industries are estimated to account for more than 20% of plant energy consumption. However, accurately determining the impact of new separation technology solutions can sometimes be difficult, especially when evaluating a slate of new candidate separation technologies, each of which has its own separation performance, energy demand, and capital cost. In these cases, a typical approach is to assess each new separation technology by collecting performance and cost information and then using that information to develop a techno-economic analysis to identify overall benefits. While this approach is thorough, it can be time consuming and can hinder reaching a critical understanding of the potential of a given separation challenge, especially when there is no known solution. To address these issues, we developed an assessment methodology, using industrial screening processes, that can be used to better understand the potential impacts of addressing a given separation challenge. This paper presents an overview of our separation challenge stream assessment methodology. The methodology involves defining an “ideal” separator and deriving the associated minimum separation energy. The “ideal” separator represents the most optimistic outlook of a given opportunity so the maximum impact from existing and not-yet-developed solutions can be assessed. Using established biorefinery models, we applied the methodology to 10 different separation challenge streams from two different biomass conversion platforms to identify the type of information that can be obtained. Three of the ten challenge streams assessed had maximum possible cost savings predictions >20%, and associated reductions in process energy carbon intensity ranging from 0 to 54%. Two streams had cost and energy savings potential that were < 5%. Some of the opportunity drivers from the various assessments include higher product yields, reduction or elimination of downstream equipment, new co-products, and cost savings associated with raw materials and energy consumption. The information from these assessments can help guide the selection or development of new separation technology solutions based on the various potential factors that drive the projected benefits.

09 BIOMASS FUELS↗

Techno-Economic Analysis and Life-Cycle Assessment of Emerging Technologies for Bioprocessing Separations

Limited availability, rising costs, and environmental concerns about fossil fuels have generated considerable interest in finding alternative, renewable sources including biomass, which can be converted into a number of biofuels and bioproducts. In comparison to petroleum-based products, high processing costs, mainly associated with bioprocessing separations, limit widespread implementation of biofuels and bioproducts. Bioprocess-related separations are also complicated, regardless of the conversion pathway, due to the dilute nature of products and the chemically complex mixtures that result from biomass deconstruction. In many cases, bioprocessing separation approaches lack a technology baseline, or definition of the state of technology (SOT). This work focuses on evaluating the technology readiness of novel separations technologies for the conversion of biomass into biofuels and bioproducts and will address three key topics: 1) SOT description, 2) economic viability analysis of both SOT and innovative separations, and 3) environmental impact assessment of both SOT and novel processes. The current SOT for lignin valorization, dilute carbon recovery, and impurity removal is used to identify potential opportunities for improvement and provide a baseline for comparison with the emerging technologies. Detailed techno-economic analysis (TEA) and life cycle assessment (LCA) are applied to understand the key drivers and challenges related to the economic feasibility and environmental impacts, respectively.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

The Cell Utilized Partitioning Model as a Predictive Tool for Optimizing Counter-Current Chromatography Processes

Counter-current chromatography (CCC) is capable of unique elution modes that isolate analytes using the movement of the stationary phase in addition to moving the mobile phase. These modes include elution-extrusion CCC (EECCC) and dual-mode CCC (DM CCC) that are not possible in traditional solid-liquid chromatography systems. Although EECCC and DM CCC are widely used to recover highly retained components, to our knowledge, optimizing the elution process in these modes with predictive models has not been reported. To address this gap, we developed a predictive model for CCC dubbed the Cell Utilized Partitioning (CUP) model. The CUP model accurately predicts the effluents of multicomponent separations in EECCC and DM CCC modes when compared to experimental data. Furthermore, CUP model simulations were extended to investigate the influence of operating and intrinsic parameters on the yield and productivity, and to compare the separation performances of EECCC and DM CCC in various conditions. The results demonstrate that low distribution constants, usually a KD less than 1, and a selectivity > 1.3, under specific flowrate ranges, increase both productivity and yield. From these results, generalized optimization and scaleup guidelines are proposed that can apply to research settings and to industrial processes to maximize preparative CCC performance.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

A single-component water-lean post-combustion CO 2 capture solvent with exceptionally low operational heat and total costs of capture – comprehensive experimental and theoretical evaluation

A comprehensive evaluation of a recently developed water-lean amine-based solvent, namely N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (2-EEMPA), has been performed to analyze its post-combustion CO 2 capture performance. This evaluation comprises (1) fundamental characterization of the solvent–CO 2 interaction using vapor–liquid equilibria, kinetics and viscosity measurements; (2) process characterization of the CO 2 capture performance as measured in a laboratory scale continuous flow system and via Aspen Plus® simulation using a flue gas simulant; as well as (3) a full techno economic analysis of the capture process at industrial scale with corresponding projections of critical metrics. This paper summarizes the many parts of this comprehensive evaluation and shows how the various parts come together to empower validated conclusions about its process performance. Notably, it is projected that this solvent can operate at a regeneration heat rate of 2.0 GJ per tonne CO 2 for post-combustion capture, and at a total cost of capture of $50.6/tonne CO 2 . Overall, with further process optimization significant reductions in the capture cost are predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of 2016 through 2018 Testing of Air-Purifying Respirator (APR) Cartridge Performance on Multiple Hanford Tank Headspaces and Exhausters

Between 2016 and 2018, 28 air purifying respirator (APR) cartridge tests were performed on headspace vapors from seven Hanford waste storage tanks (SY-102, A-101, BY-108, AX-101, BY-110, SX-101, and SX-104) and seven waste tank exhausters (AP in 2016, AP in 2018, 702-AZ, AN and AW in 2016, and AX and 702-AZ in 2017). All but two tests were conducted under static conditions absent waste-disturbing activities in the subject tanks or tank farms. The two exceptions were cartridges tested with vapors from 702-AZ in 2017 when samples were taken during waste-disturbing activities. Multipurpose APR cartridges, SCOTT 7422-SD1 and 7422-SC1, were tested on samples from each of the 14 tanks or exhausters. Out of 612 Chemicals of Potential Concern (COPCs), only ammonia, mercury, N-nitrosodimethylamine (NDMA), 2,5-dimethylfuran, 2,5-dihydrofuran, furan, and 1,3-butadiene exhibited breakthroughs with outlet concentrations that were >10% of their Occupational Exposure Limits (OEL).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biopower: Impact of Biofuels Deployment to Replace Petroleum Liquids in Stationary Power Applications

Petroleum-based liquids are used in a portion of power generation applications in the United States, predominantly in the New England, Middle Atlantic, South Atlantic, and Pacific-Noncontiguous regions. Power plants that burn petroleum liquids, such as distillate or residual fuel oils, are generally used for short periods to accommodate peak electricity demands. The Energy Information Administration (EIA) estimated the U.S. consumption of petroleum liquids for electricity generation at 27 million barrels in 2018, representing a cost of $2.4 billion annually. This study assesses the potential to displace all or part of the petroleum liquids in U.S. power generation with biofuels. The biofuels for this application are assumed to be derived from terrestrial feedstocks, with conversion routes of both fast pyrolysis (bio-oil) and hydrothermal liquefaction (bio-crude). Regional models were used to assess the availability and cost of three different base materials: clean wood, forest residues, and corn stover; each was evaluated in the laboratory at small or experimental scales for conversion to bio-oil or bio-crude. The estimated biofuel production quantities depend on equivalent heating versus the current heavy fuel. In this report, the availability of each type of biomass for each section of the U.S. Census division is estimated using a conservative broker price (in each case) of $ 80 per dry tonne. The results show that the petroleum-liquid power generation in each of the Census Divisions could be supplied by one or more of the feedstocks evaluated. For all regions, clean wood supplies (only) could provide ample supply. For all but two regions (Middle Atlantic and New England), forest residues alone are sufficient. Finally, for all regions but three (Middle Atlantic, New England, and South Atlantic), corn stover alone is adequate. The Minimum Fuel Selling Price (MFSP) of bio-oil and bio-crude were also estimated for each feedstock type and Census Division. This analysis showed that fast pyrolysis bio-oil projections to be lower (14% on average) than current wholesale petroleum-based heating oil prices in each of the regions, assuming 100 dry tonnes/day processing capacity. However, bio-crude predictions were significantly higher (2X) in all cases. The effect of biorefinery size was also quantified. Based on the preliminary results in this study, it is apparent the biofuels could be an economical alternative for current petroleum liquids in U.S. power generation. However, additional research is needed to determine the necessary biofuel characteristics to support existing generation equipment. It is recommended that both power generation and biofuel production stakeholders to be engaged to outline the research and testing needed to identify the technical hurdles to enable the opportunity.

02 PETROLEUM↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Overview of 2017 Through 2018 Testing of Powered Air-Purifying Respirator (PAPR) Cartridge Performance on Multiple Hanford Tank Headspaces and Exhausters

Between 2017 and 2018, 10 powered air-purifying respirator (PAPR) cartridge tests were performed on headspace vapors from three Hanford tanks (BY-108, SX-101, and SX-104) and two Hanford Tank Farm exhausters (AP in 2018 and AX in 2017). All tests were conducted under static conditions absent waste-disturbing activities in the subject tanks or tank farms. Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota), were tested on each of the five tanks or exhausters. Out of 61 1 Chemicals of Potential Concern (COPCs), only ammonia and 2,5-dimethylfuran exhibited breakthroughs with outlet concentrations that were greater than 10% of their Occupational Exposure Limits (OEL). For 2,5-dimethylfuran, elevated concentrations found in blank tube samples made the elevated outlet measurements for this COPC questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗