Search NASA⌕ Search

Engineering topics

Freeman, J.

Publications and source records attributed to Freeman, J..

At least 19 records

Test beam study of SiPM-on-tile configurations

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. Furthermore, these studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

47 OTHER INSTRUMENTATION↗

Fermilab Test Beam Facility Annual Report: FY19

This Technical Memorandum (TM) summarizes the Fermilab Test Beam Faciltiy (FTBF) operations for FY2019. It is one of a series of annual publications intended to gather information in one place. This TM discusses the experiments performed at the Test Beam from November 2018 to July 2019. The experiments are listed in Table 1. Each experiment wrote a summary that was edited for clarity and is included in this report.

43 PARTICLE ACCELERATORS↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Here, the 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Test Beam Facility Annual Report FY17

This Technical Memorandum (TM) summarizes the Fermilab Test Beam operations for FY2017. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF and are listed in Table 1. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

43 PARTICLE ACCELERATORS↗

Data preservation at the Fermilab Tevatron

The Fermilab Tevatron collider's data-taking run ended in September 2011, yielding a dataset with rich scientific potential. The CDF and D0 experiments each have approximately 9 PB of collider and simulated data stored on tape. A large computing infrastructure consisting of tape storage, disk cache, and distributed grid computing for physics analysis with the Tevatron data is present at Fermilab. The Fermilab Run II data preservation project intends to keep this analysis capability sustained through the year 2020 and beyond. To achieve this goal, we have implemented a system that utilizes virtualization, automated validation, and migration to new standards in both software and data storage technology and leverages resources available from currently-running experiments at Fermilab. Lastly, these efforts have also provided useful lessons in ensuring long-term data access for numerous experiments, and enable high-quality scientific output for years to come.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel programmable power supply with temperature compensation for silicon sensors

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QIE: Performance Studies of the Next Generation Charge Integrator

The Phase 1 upgrade of the Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) will include two new generations (named QIE10 and QIE11) of the radiation-tolerant flash ADC chip known as the Charge Integrator and Encoder or QIE. The QIE integrates charge from a photo sensor over a 25 ns time period and encodes the result in a non-linear digital output while having a good sensitivity in both the higher and the lower energy values. The charge integrator has the advantage of analyzing fast signals coming from the calorimeters as long as the timing and pulse information is available. The calorimeters send fast, negative polarity signals, which the QIE integrates in its non-inverting input amplifier. The input analog signal enters the QIE chip through two points: signal and reference. The chip integrates the difference between these two values. This helps in getting rid of the incoming noise, which is effectively cancelled out in the difference. Over a period of about six months between September, 2013 and April, 2014 about 320 QIE10 and about 20 QIE11 chips were tested in Fermilab using a single-chip test stand where every individual chip was tested for its characteristic features using a clam-shell. The results of those tests performed on the QIE10 and QIE11 are summarized in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Multiple Tools for Flat Plate Photovoltaic Modeling Against Measured Data

This report expands upon a previous work by the same authors, published in the 40th IEEE Photovoltaic Specialists conference. In this validation study, comprehensive analysis is performed on nine photovoltaic systems for which NREL could obtain detailed performance data and specifications, including three utility-scale systems and six commercial scale systems. Multiple photovoltaic performance modeling tools were used to model these nine systems, and the error of each tool was analyzed compared to quality-controlled measured performance data. This study shows that, excluding identified outliers, all tools achieve annual errors within +/-8% and hourly root mean squared errors less than 7% for all systems. It is further shown using SAM that module model and irradiance input choices can change the annual error with respect to measured data by as much as 6.6% for these nine systems, although all combinations examined still fall within an annual error range of +/-8.5%. Additionally, a seasonal variation in monthly error is shown for all tools. Finally, the effects of irradiance data uncertainty and the use of default loss assumptions on annual error are explored, and two approaches to reduce the error inherent in photovoltaic modeling are proposed.

14 SOLAR ENERGY↗

Reference Manual for the System Advisor Model's Wind Power Performance Model

This manual describes the National Renewable Energy Laboratory's System Advisor Model (SAM) wind power performance model. The model calculates the hourly electrical output of a single wind turbine or of a wind farm. The wind power performance model requires information about the wind resource, wind turbine specifications, wind farm layout (if applicable), and costs. In SAM, the performance model can be coupled to one of the financial models to calculate economic metrics for residential, commercial, or utility-scale wind projects. This manual describes the algorithms used by the wind power performance model, which is available in the SAM user interface and as part of the SAM Simulation Core (SSC) library, and is intended to supplement the user documentation that comes with the software.

17 WIND ENERGY↗

Wind Technology Modeling Within the System Advisor Model (SAM) (Poster)

This poster provides detail for implementation and the underlying methodology for modeling wind power generation performance in the National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). SAM's wind power model allows users to assess projects involving one or more large or small wind turbines with any of the detailed options for residential, commercial, or utility financing. The model requires information about the wind resource, wind turbine specifications, wind farm layout (if applicable), and costs, and provides analysis to compare the absolute or relative impact of these inputs. SAM is a system performance and economic model designed to facilitate analysis and decision-making for project developers, financers, policymakers, and energy researchers. The user pairs a generation technology with a financing option (residential, commercial, or utility) to calculate the cost of energy over the multi-year project period. Specifically, SAM calculates the value of projects which buy and sell power at retail rates for residential and commercial systems, and also for larger-scale projects which operate through a power purchase agreement (PPA) with a utility. The financial model captures complex financing and rate structures, taxes, and incentives.

17 WIND ENERGY↗

SAM Technical Review Committee Final Report: Summary and Key Recommendations from the Onsite TRC Meeting Held April 22-23, 2013

The System Advisor Model (SAM) is a broad and robust set of models and frameworks for analyzing both system performance and system financing. It does this across a range of technologies dominated by solar technologies including photovoltaics (PV) and concentrated solar power (CSP). The U.S. Department of Energy (DOE) Solar Energy Technology Program requested the SAM development team to review the photovoltaic performance modeling with the development community and specifically, with the independent engineering community. The report summarizes the major effort for this technical review committee (TRC).

14 SOLAR ENERGY↗

Preliminary Raman Spectroscopic Survey on a Martian Meteorite - Los Angeles

A Raman survey on a flat-sawn rock slab provides the major mineralogy of martian meteorite Los Angeles. Three unreported accessory minerals and seven terrestrial alteration products and contaminants (organic and inorganic) were also found. Additional information is contained in the original extended abstract.

Wang, A.↗

Lunar mining equipment

This document contains preliminary concepts for mining and beneficiation of lunar regolith from a 50 metric ton/day mine. Assumptions for the design are outlined below. Lunar regolith is the material to be mined. Since it is already a fine-grained material, the two steps of crushing and breakup from a rock surface are eliminated. The size of the operation was set at 50 metric tons of regolith/day for a three-year period. Operations will occur around the clock to make most efficient use of equipment, thus we assume 24 hr/day. For simplicity we have assumed that the lunar regolith has a uniform density of 1.68 and that it can be mined to a depth of 6 m. No research was done on power supply or distribution. It was left to others to consider the various trade-offs between nuclear and solar power and to design the needed utility system.

Bekkedahl, S.↗

Report on opportunities and/or techniques for high-caliber experimental research (other) proposals for SSPEX

Brief discriptions of the following 13 experiments are included: ultrahigh vacuum petrology facility; artificial comet free flyer; artificial comet (tethered); cosmic dust detector; cosmic dust collector; dust collection using tethered satellites; artificial magnetosphere; microgravity petrological studies; slitless ultraviolet spectrometer; orbital determination and capture experiment (ODACE); high velocity sputtering of amorphous silicates; particle release experiments; and calibration of gamma and X-ray remote sensingprobes.

Nuth, J. A., III↗