Freeman, Matthew Stouten

Publications and source records attributed to Freeman, Matthew Stouten.

At least 19 records

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

47 OTHER INSTRUMENTATION↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Imaging and Tomography at NIF [Slides]

The presentation at the first Prompt Radiation Detection and Imaging Workshop covered fast neutron and tomography work at the National Ignition Facility (NIF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Gamma Imaging on NIS3

Explore the source record for details and available documents.

Geppert-Kleinrath, Verena↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

(U) PRAD0697 & PRAD0698: Complex Loading of CeO₂ Powder

Cerium(IV) oxide (CeO₂) powder is shock compressed using the Precision High Energy-density Liner Implosion eXperiment (PHELIX) platform. Experimental results are compared against several modeling approaches. Compaction behavior is best captured with a P-∝ model, which calculates CeO₂ powder bulk densities within 80-99% of experimental values but overpredicts densi cation at the cylindrical target's outer radius and center by up to 20%. Preliminary calculations suggest that accuracy could be increased with the inclusion of a coupled strength model. Several common computational modeling approaches for the shock compression response of granular materials and the magnetohydrodynamic (MHD) force upon the impactor/liner in pulsed power compression experiments are investigated and analyzed for their validity. The Bi-linear Ramp, P-∝ PACXP, and P-∝ Menikoff-Kober continuum compaction models are calibrated to planar impact Hugoniot data for CeO₂ powder and used to predict the powder's shock compaction response under non-planar shock wave compression. MHD calculations of the PHELIX pulsed power driver are performed using an idealized resistor-inductor-capacitor (RLC) circuit calibrated to previous experiments. All simulations are performed using the LANL code FLAG. Two validation experiments are computationally designed using the calibrated compaction and circuit models, executed using the PHELIX platform on CeO₂ targets with initial porous densities of 3.95 and 4.03 g/cm³, measured with proton radiography, and analyzed against the model predictions. The two P-∝ models more accurately describe CeO₂ powder densi cation than the Bi-linear Ramp model. However, the two P-∝ models overpredict bulk density of the shock compressed CeO₂ powder by up to 20% when the appropriate impact velocities are applied. MHD calculations for both validation experiments underpredict liner impact velocities by 4-11% when using the idealized RLC circuit model calibrated to previous experiments. Compensating underpredictions of impact velocity and overpredictions of powder densication lead to a false accuracy in pre-shot calculations compared to experimental data. To improve correlation between simulations and experiments, the following improvements are suggested: 1. A coupled strength model for CeO₂ powder that updates strength as a function of porosity and applied stress. 2. An improved MHD circuit model that more accurately captures the PHELIX machine.

36 MATERIALS SCIENCE↗

LANSCE Pulse

For more than four decades, the United States has relied on the Los Alamos Neutron Science Center (LANSCE) accelerator to deliver high-energy, high-power proton beams in support of national security science. Today the LANSCE facility is a center for materials and nuclear research supporting National Nuclear Security Administration (NNSA) and Department of Energy (DOE) missions.

43 PARTICLE ACCELERATORS↗

A liquid VI scintillator cell for fast-gated neutron imaging

Here, the design of a new fast-gated neutron imaging system for the National Ignition Facility with much stricter timing constraints than a previous system has prompted the search for a fast scintillator material that can be used in imaging. A novel imaging cell based on Liquid VI has recently been developed with Eljen Technology and characterized at the Special Technologies Laboratory and the Los Alamos Neutron Science Center. The results show superior timing characteristics and spatial resolution, and sufficient light production for the new system compared to fast plastic scintillators previously used in neutron imaging. While the primary application is in inertial confinement fusion diagnostics, the imaging cell can be used in any fast-gated imaging application where timing characteristics and spatial resolution are of concern.

47 OTHER INSTRUMENTATION↗