Search NASA⌕ Search

Engineering topics

Frenje, J. (ORCID:0000000168460378)

Publications and source records attributed to Frenje, J. (ORCID:0000000168460378).

Diagnosing inertial confinement fusion ignition

Abstract Fusion ignition by inertial confinement requires compression and heating of the fusion fuel to temperatures in excess of 5 keV and densities exceeding hundreds of g/cc. In August 2021, this scientific milestone was surpassed at the National Ignition Facility (NIF), when the Lawson criterion for ignition was exceeded generating 1.37MJ of fusion energy (Abu-Shawareb et al 2022 Phys. Rev. Lett. 129 075001), and then in December 2022 target gain >1 was realized with the production of 3.1MJ of fusion energy from a target driven by 2.0MJ of laser energy (Abu-Shawareb et al 2024 Phys. Rev. Lett. 132 065102). At the NIF, inertial confinement fusion research primarily uses a laser indirect drive in which the fusion capsule is surrounded by a high-Z enclosure (‘hohlraum’) used to convert the directed laser energy into a symmetric x-ray drive on the capsule. Precise measurements of the plasma conditions, x-rays, γ -rays and neutrons produced are key to understanding the pathway to higher performance. This paper discusses the diagnostics and measurement techniques developed to understand these experiments, focusing on three main topics: (1) key diagnostic developments for achieving igniting plasmas, (2) novel signatures related to thermonuclear burn and (3) advances to diagnostic capabilities in the igniting regime with a perspective toward developments for intertial fusion energy.

Moore, A. S. (ORCID:0000000221258882)↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

Temperature and density dependence of Kr L-shell spectrum in hot dense plasmas

Kr L-shell spectroscopy modeling results are discussed in this paper, focusing on the n = 4 to n = 2 line transitions of Be- and Li-like Kr ions. Collisional radiative atomic kinetic and Stark-broadened spectral line shape calculations show electron temperature Te and density ne sensitivity in the spectrum. The combination of the Te dependence due to the relative intensity of Be-like to Li-like line emissions in the range from 1.5 to 3 keV and the ne sensitivity from the Stark broadening effect on the line shapes in the range from 5×1023 to 2×1024/ cc results in a spectrum that can be employed to diagnose Te and ne. Two different collisional radiative atomic kinetic models i.e., Prismspect [J. J. MacFarlane, et al., Int. Fusion Sci. Appl. Conf. Proc. 457 (2003)] and ABAKO [Florido, et al., PRE, 80, 056402 (2009)] produce similar results in level populations and spectra. In x-ray spectroscopy of implosion cores, this Kr L-shell spectrum may prove useful in an intermediate Te range in which Ar is too ionized for its K-shell to be of diagnostic value and Kr is not ionized enough for its K-shell emission to be useful.

Physics↗