Search NASA⌕ Search

Engineering topics

Freye, Christopher Edward

Publications and source records attributed to Freye, Christopher Edward.

New methods for trace analysis of gamma-irradiated pentaerythritol tetranitrate

High explosives (HEs) are used in a diverse range of applications in which they could be exposed to various radiation levels that may cause potential chemical changes. This study further evaluated pentaerythritol tetranitrate (PETN) that was previously aged with a low-level 2 kGy dose of gamma irradiation in order to understand chemical changes caused by irradiation. Both unirradiated PETN and gamma-irradiated PETN were analyzed using ultra high-pressure liquid chromatography coupled to quadrupole time of flight mass spectrometry (UHPLC-QTOF). The resulting data were processed in a non-targeted manner using Fisher's ratio analysis and multivariate curve resolution-alternating least squares (MCR-ALS) to aid in discovery and identification of the chemical changes brought about by irradiation without a priori knowledge. The application of using UHPLC-QTOF in combination with chemometric techniques for the analysis of irradiated samples has not previously been performed. Here, in this work, we show how to use this method to provide chemical information that would otherwise not be discernible, such as the discovery of degradation of the various homologues of PETN. Major differences identified with radiolytic aging of the PETN sample included decomposition products that resulted from the degradation of the trigger linkage – the O–NO 2 bonds – resulting in the formation of alcohol and aldehyde groups. Similar degradation was also observed in the PETN homologues as well as interconversion from one homologue to another.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comprehensive two-dimensional gas chromatography under low-pressure conditions

The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC × GC), allows for resolution of compounds that would typically coelute using GC. Here, in this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC × GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC × GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 °C less on the low-pressure GC × GC-TOFMS configuration compared to the conventional GC × GC-TOFMS configuration. Moreover, the compounds were separated in ~13 min on the low-pressure GC × GC-TOFMS as opposed to 33 min for conventional GC × GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC × GC-TOFMS had a lower, β corrected 2D peak capacity, n c,β,2D , of 1260 while the conventional GC × GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC × GC-TOFMS, respectively. A “real world” sample of diesel fuel was tested on the low-pressure and conventional GC × GC-TOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC × GC-TOFMS configuration was higher than that of the conventional GC × GC-TOFMS method.

47 OTHER INSTRUMENTATION↗

Gel Permeation Chromatography Methods for Stockpile Relevant PBXs

In order to accurately characterize chemical changes to the binder in plastic-bonded explosives (PBXs) it is important to develop new gel permeation chromatography (GPC) methodologies as well as update previous methods. Herein we present new and updated GPC methodology for Viton A, Kraton G, and Oxy 461. The methods developed were specifically designed for Malvern OMNISEC with a Mixed C column, but minor modifications could be made to these methods to make applicable to other instrumentation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANL-UW Collaboration on LC-QTOF Datasets (Annual Report)

Prior to the application of non-targeted chemometric techniques (i.e., Fisher ratio analysis), pre-processing steps must be carried out on the data collected using liquid chromatography-quadrupole time of flight (LC-QTOF) mass spectrometry. Data compression is the most important pre-processing step due to the vast number of high-resolution mass channels (m/z; 0.0001 Da) collected. Our first approach was to bin the mass spectral dimension to 0.01 Da; however, this approach was computationally expensive and did not preserve the high-resolution data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of Blue Discoloration in PBX 9404 using Ultrahigh Pressure Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry

PBX 9404, composed of 94 wt% HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazoctane), 3 wt% NC (nitrocellulose), 2.9 wt% CEF (tris(beta-chloroethyl) phosphate) and 0.1 wt% DPA (diphenylamine), has often been observed with a slight to entire blue discoloration of the manufactured prills. This blue discoloration has been observed since the formulation development of PBX 9404 in the late 1950s. In order to determine the source of the blue discoloration in PBX 9404, ultraviolet/visible (UV/Vis) absorbance of PBX 9404 and two potential candidates for the discoloration, p-nitrosodiphenylamine (p-NDPA) and N-nitrosodiphenylamine (N-NDPA) were evaluated. An absorbance band at 590 nm in PBX 9404 sample was attributed to the blue discoloration while p-NDPA and N-NPDA had different absorbance bands. Using the knowledge gained from the UV/Vis analysis, a semi-targeted approach using ultrahigh pressure liquid chromatography coupled to UV/Vis detector and quadrupole time of flight mass spectrometry (UHPLC-UV/Vis-QTOF) was implemented. Investigating the UHPLC-UV/Vis-QTOF chromatograms at a wavelength of 590 nm, a single compound was tentatively identified as being the source of the blue discoloration. Targeted tandem mass spectrometry (MS/MS) on the compound and subsequent analysis indicated that 4,4 -{[4-(Phenylimino)-2,5-cyclohexadien-1-ylidene]methylene}bis(N-phenylaniline), also known as Spirit Blue Base, was the source of the blue discoloration, which was confirmed using a standard. Here, a theory on the formation of Spirit Blue Base in PBX 9404 involving DPA, nitric acid (HNO 3 ) / nitrogen oxide(s) NO x , and formaldehyde is proposed.

36 MATERIALS SCIENCE↗

Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry and Fisher Ratio Analysis for Discovery-Based Analysis

The ability to discover minute differences between samples or sample classes for ultrahigh performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) can be a challenging endeavor especially when these differences are not known a priori. Indeed a typical UHPLC-QTOF analysis time of ~15 minutes can generate over 4 gigabytes of information for a single sample. Implementation of chemometrics such as Fisher ratio (F-ratio) analysis will allow the analyst to quickly and precise probe the chemical differences between different samples or sample classes. F-ratio analysis can be used to find sample or sample class distinguishing compounds reducing the 5 gigabytes of information into a simple, yet informative hit list. Moreover through combinatorial rearrangement, it is possible to determine a F-ratio threshold to separate the real and non-real hits. The F-ratio software presented herein is a semi-automated algorithm that processes the raw, exported .csv files from the SCIEX 500R QTOF in as little as 30 seconds. While further research is needed to modify and perfect the software to deal with high resolution mass spectra precise to 0.0001 Daltons, the current software, precise to 0.1 Da, is able to find significant chemical differences despite some of them being at extremely low concentrations nearing the limit of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linking chemical precursors to the synthesis of erythritol tetranitrate

Erythritol tetranitrate (ETN) is a homemade explosive with high explosive performance which can easily be synthesized using widely available chemical precursors. Ascertaining the manner in which ETN is synthesized and being able to trace the ETN back to its precursor materials may aid in the forensic identification. As a proof of concept, seven different types of ETN were synthesized with laboratory grade materials as well as commercially available chemicals from the hardware store and grocery store. The seven different types of solid ETN and the reaction quenches were analyzed using high performance liquid chromatography (HPLC). Partial least squares discriminant analysis (PLS-DA) was used to probe the different classes of ETN and reaction quenches. Several PLS-DA models were produced with the seven different types of ETN and quenches having their own classification, ETN and quenches based on their acid source, and ETN and the quenches based on their nitrate source. Regardless of which classification manner was used, there were no differences found between the different types of ETN or their reaction quenches. Furthermore, it is demonstrated that there is inherent variability in the synthesis of ETN making HPLC an unreliable method to determine the source of the synthesis materials. Elemental impurities were measured in seven solid ETN samples and their reaction quenches by inductively coupled plasma mass spectrometry (ICP-MS). No differences were discovered between the solid ETN samples, but there were trace metals found in the reaction quenches which were found to be identifiers of the source material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗