Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Zero-CO Residential Natural Gas Furnace

Residential natural gas furnaces are widely used in the US homes. Manufacturers dedicate significant design and testing resources to meet requirements of design standards. One area of these standards is controlling flue gas carbon monoxide (CO) emissions. To more effectively reduce CO emissions at the flue, we developed a novel catalyst-assisted approach that integrated a low Pt/Rh loading acidic gas reduction (AGR) catalyst with three-way catalyst (TWC) or diesel oxidation catalyst (DOC) components. Compact catalysts were fabricated and assembled into tubular components, which can be seamlessly incorporated into the primary heat exchanger of a representative commercially available condensing furnace. The retrofitted furnace was demonstrated and tested following ANSI/ASHRAE Standard 103-2017. Experimental results showed that both AGR/TWC and AGR/DOC configurations achieved near-zero CO emissions under steady-state and cold-start conditions, compared with up to 500 ppm at a cold start and 17 ppm in a steady state in the OEM furnace. The catalyst-assisted furnaces also exhibited an annual fuel utilization efficiency improvement of more than 1.5% relative to the baseline unit, with a manageable pressure drop of 2.0−2.5 in. of water column. These results demonstrate that the catalyst-assisted approach can effectively eliminate CO emissions and improve energy efficiency. The technology has broad applicability for residential and commercial gas-fired heating systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Optimizing flow condensation models for next-generation refrigerants in axial micro-fin aluminum tubes

To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes