Friedlander, S. K.

Publications and source records attributed to Friedlander, S. K..

Measuring Sodium Chloride Contents of Aerosols

Amount of sodium chloride in individual aerosol particles measured in real time by analyzer that includes mass spectrometer. Analyzer used to determine mass distributions of active agents in therapeutic or diagnostic aerosols derived from saline solutions and in analyzing ocean spray. Aerosol particles composed of sodium chloride introduced into oven, where individually vaporized on hot wall. Vapor molecules thermally dissociated, and some of resulting sodium atoms ionized on wall. Ions leave oven in burst and analyzed by spectrometer, which is set to monitor sodium-ion intensity.

Sinha, M. P.

Mass Spectrometer for Airborne Micro-Organisms

Bacteria and other micro-organisms identified continously with aid of new technique for producing samples for mass spectrometer. Technique generates aerosol of organisms and feeds to spectrometer. Given species of organism produces characteristic set of peaks in mass spectrum and thereby identified. Technique useful for monitoring bacterial makeup in environmental studies and in places where cleanliness is essential, such as hospital operating rooms, breweries, and pharmaceutical plants.

Sinha, M. P.

Real-time measurement of sodium chloride in individual aerosol particles by mass spectrometry

The method of particle analysis by mass spectrometry has been applied to the quantitative measurement of sodium chloride in individual particles on a real-time basis. Particles of known masses are individually introduced, in the form of a beam, into a miniature Knudsen cell oven (1600 K). The oven is fabricated from rhenium metal sheet (0.018 mm thick) and is situated in the ion source of a quadrupole mass spectrometer. A particle once inside the oven is trapped and completely volatilized; this overcomes the problem of partial volatilization due to particles bouncing from the filament surface. Individual particles are thermally volatilized and ionized inside the rhenium oven, and produce discrete sodium ion pulses whose intensities are measured with the quadrupole mass spectrometer. An ion pulse width of several milliseconds (4-12 ms) is found for particles in the mass range 1.3 x 10 to the -13th to 5.4 x 10 to the -11th g. The sodium ion intensity is found to be proportional to the particle mass to the 0.86-power. The intensity distribution for monodisperse aerosol particles possesses a geometric standard deviation of 1.09, showing that the method can be used for the determination of the mass distribution function with good resolution in a polydisperse aerosol.

Sinha, M. P.

Laser-Assisted Analysis of Aerosol Particles

Proposed instrument makes rapid mass-spectrometric analyses of individual particles in aerosols. Each particle vaporized and ionized by intense laser pulse, which creates ions of minimum complexity. Ability to analyze single aerosol particles continuously makes technique suitable for detection of toxic aerosol particles on real-time basis and for identification of their sources.

Sinha, M. P.

Analysis of individual biological particles by mass spectrometry

A method is developed for the detection and identification of biological particles introduced in aerosol form into a quadrupole mass spectrometer. The bacterial aerosol is generated by nebulizing an ethanol suspension. The particles are introduced into the ion source of the mass spectrometer in the form of a beam, where they are individually volatilized on a V-type rhenium filament and ionized by electron impaction. It is shown that the average intensity of a mass peak is obtained from the pulse height distribution of about a thousand ion pulses from different particles. Pseudomonas putida, Bacillus subtilis, and Bacillus cereus are used in the studies. Differences between the relative intensities of mass peaks in the spectra from P. putida and B. subtilis are found and may provide a method for differentiation of microorganisms. The results for the two species agree reasonably well with those reported by Kistemaker et al. (1975) and Schulten et al. (1973). However, there exist some differences between the two spectra in the high mass range due to the difference in the pyrolysis conditions.

Sinha, M. P.

Measurement of mass distribution of chemical species in aerosol particles

Aerosols may be generated through the nebulizing of solutions and the evaporation of their solvent, leaving the dry solute particles. Attention is presently given to a method for the direct determination of the masses of chemical species in individual aerosol particles on a continuous, real-time basis, using mass spectrometry. After the aerosol particles are introduced into the ion source of a quadrupole mass spectrometer, the particles impinge on a hot rhenium filament in the mass spectrometer's ion source. The resulting vapor plume is ionized by electron bombardment, and a pulse of ions is generated by each particle. The intensities of different masses in the ion pulses can then be measured by the mass spectrometer.

Sinha, M. P.

Continuous Monitoring of Aerosols

Online spectrometer monitors composition of individual aerosol particles. Single aerosol particles up to about 5 microns in diameter are analyzed for chemical composition, yielding valuable information on nature of pollution source. Tests show system has promise for monitoring oxidation of sulfur dioxide to sulfates important in controlling pollution from coal-fired power plants.

Mahadeva, S. P.

Particle analyzing method and apparatus

The rapid chemical analysis of particles in aerosols can be accomplished using an apparatus which produces a controlled stream of individual particles from an environment, and another apparatus which vaporizes and ionizes the particles moving in free flight, for analysis by a mass spectrometer. The device for producing the stream of particles includes a capillary tube through which the air with suspended particles moves, a skimmer with a small opening spaced from an end of the capillary tube to receive particles passing through the tube, and a vacuum pump which removes air from between the tube and skimmer and creates an inflow of air and particles through the tube. The particles passing through the skimmer opening can be simultaneously vaporized and ionized while in free flight, by a laser beam of sufficient intensity that is directed across the path of the free flying particles.

Sinha, M. P.